15:33:54 #38494 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Strip detector commissioning 15:33:54 #38494 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:33:56 #38494 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 15:33:56 #38494 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 15:33:56 #38494 /GetReadyTheDischarge: Going with gas pressure 12 15:33:56 #38494 /GetReadyTheDischarge: Going with gas type H 15:33:57 15:33:57 #38494 /GetReadyTheDischarge: Discharge with Hydrogen request 15:33:57 #315:33:57 #38494 /GetReadyTheDischarge: Discharge with 12 mPa request 15:33:57 #38494 /GetReadyTheDischarge: Going with CD_orientation ACW 15:33:57 #38494 /GetReadyTheDischarge: Discharge with CD ACW request 15:34:00 #38494 /VacuumLog: Chamber: 3.12 mPa, 30.50 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 22.56 V 15:34:04 #38494 /GetReadyTheDischarge: Bt capacitor charging started 15:34:04 #38494 /VacuumLog: Chamber: 16.00 mPa, 30.40 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 23.24 V 15:34:08 #38494 /VacuumLog: Chamber: 12.90 mPa, 30.40 C, ForVacuum: 4.5 Pa, Gas: H2, GasValve: 21.44 V 15:34:08 #38494 /GetReadyTheDischarge: Cd capacitor charging started 15:34:08 #38494 /ChargingResistorsAllOFF: Diving into .. 15:34:08 #38494 /GetReadyTheDischarge: U_Bt: 1000, Hrana: 98 15:34:08 #38494 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 15:34:09 #38494 /GetReadyTheDischarge: Charging ... HV=-10 V 15:34:09 #38494 /GetReadyTheDischarge: Charging ... HV=-10 V 15:34:09 #38494 /GetReadyTheDischarge: Charging ... HV=-10 V 15:34:10 #38494 /GetReadyTheDischarge: Charging ... HV=20 V 15:34:10 #38494 /GetReadyTheDischarge: Charging ... HV=20 V 15:34:11 #38494 /GetReadyTheDischarge: Charging ... HV=70 V 15:34:11 #38494 /GetReadyTheDischarge: Charging ... HV=70 V 15:34:12 #38494 /GetReadyTheDischarge: Charging ... HV=70 V 15:34:12 #38494 /GetReadyTheDischarge: Charging ... HV=117 V 15:34:12 #38494 /GetReadyTheDischarge: Charging ... HV=117 V 15:34:13 #38494 /GetReadyTheDischarge: Charging ... HV=164 V 15:34:13 #38494 /GetReadyTheDischarge: Charging ... HV=164 V 15:34:14 #38494 /GetReadyTheDischarge: Charging ... HV=164 V 15:34:14 #38494 /GetReadyTheDischarge: Charging ... HV=210 V 15:34:15 #38494 /VacuumLog: Chamber: 12.50 mPa, 30.40 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 22.01 V 15:34:15 #38494 /GetReadyTheDischarge: Charging ... HV=210 V 15:34:15 #38494 /GetReadyTheDischarge: Charging ... HV=255 V 15:34:16 #38494 /GetReadyTheDischarge: Charging ... HV=255 V 15:34:16 #38494 /GetReadyTheDischarge: Charging ... HV=255 V 15:34:16 #38494 /GetReadyTheDischarge: Charging ... HV=300 V 15:34:17 #38494 /GetReadyTheDischarge: Charging ... HV=300 V 15:34:17 #38494 /GetReadyTheDischarge: Charging ... HV=21 V 15:34:18 #38494 /GetReadyTheDischarge: Charging ... HV=343 V 15:34:18 #38494 /GetReadyTheDischarge: Charging ... HV=343 V 15:34:18 #38494 /VacuumLog: Chamber: 12.30 mPa, 30.40 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 22.01 V 15:34:19 #38494 /GetReadyTheDischarge: Charging ... HV=383 V 15:34:19 #38494 /GetReadyTheDischarge: Charging ... HV=383 V 15:34:19 #38494 /GetReadyTheDischarge: Charging ... HV=421 V 15:34:20 #38494 /GetReadyTheDischarge: Charging ... HV=421 V 15:34:20 #38494 /GetReadyTheDischarge: Charging ... HV=462 V 15:34:21 #38494 /GetReadyTheDischarge: Cd capacitor charging finished @ 462 V 15:34:21 #38494 /GetReadyTheDischarge: Charging ... HV=462 V 15:34:21 #38494 /GetReadyTheDischarge: Charging ... HV=462 V 15:34:22 #38494 /GetReadyTheDischarge: Charging ... HV=500 V 15:34:22 #38494 /GetReadyTheDischarge: Charging ... HV=500 V Gas: H2, GasValve: 22.01 V 15:34:23 #38494 /GetReadyTheDischarge: Charging ... HV=539 V 15:34:23 #38494 /GetReadyTheDischarge: Charging ... HV=539 V 15:34:23 #38494 /GetReadyTheDischarge: Charging ... HV=539 V 15:34:24 #38494 /GetReadyTheDischarge: Charging ... HV=579 V 15:34:24 #38494 /GetReadyTheDischarge: Charging ... HV=579 V 15:34:25 #38494 /GetReadyTheDischarge: Charging ... HV=615 V 15:34:25 #38494 /GetReadyTheDischarge: Charging ... HV=615 V 15:34:26 #38494 /GetReadyTheDischarge: Charging ... HV=615 V 15:34:26 #38494 /GetReadyTheDischarge: Charging ... HV=651 V , Gas: H2, GasValve: 22.01 V 15:34:26 #38494 /GetReadyTheDischarge: Charging ... HV=651 V 15:34:27 #38494 /GetReadyTheDischarge: Charging ... HV=689 V 15:34:27 #38494 /GetReadyTheDischarge: Charging ... HV=689 V 15:34:28 #38494 /GetReadyTheDischarge: Charging ... HV=689 V 15:34:28 #38494 /GetReadyTheDischarge: Charging ... HV=723 V 15:34:29 #38494 /GetReadyTheDischarge: Charging ... HV=723 V 15:34:29 #38494 /GetReadyTheDischarge: Charging ... HV=756 V 15:34:29 #38494 /GetReadyTheDischarge: Charging ... HV=756 V 15:34:30 #38494 /GetReadyTheDischarge: Charging ... HV=756 V 15:34:30 #38494 /GetReadyTheDischarge: Charging ... HV=787 V 15:34:31 #38494 /GetReadyTheDischarge: Charging ... HV=787 V 15:34:31 #38494 /GetReadyTheDischarge: Charging ... HV=787 V 15:34:31 #38494 /GetReadyTheDischarge: Charging ... HV=819 V 15:34:32 #38494 /GetReadyTheDischarge: Charging ... HV=819 V 15:34:32 #38494 /GetReadyTheDischarge: Charging ... HV=850 V 15:34:33 #38494 /GetReadyTheDischarge: Charging ... HV=850 V 15:34:33 #38494 /GetReadyTheDischarge: Charging ... HV=850 V 15:34:34 #38494 /GetReadyTheDischarge: Charging ... HV=880 V 15:34:34 #38494 /GetReadyTheDischarge: Charging ... HV=880 V 15:34:34 #38494 /GetReadyTheDischarge: Charging ... HV=910 V 15:34:35 #38494 /GetReadyTheDischarge: Charging ... HV=910 V 15:34:35 #38494 /GetReadyTheDischarge: Charging ... HV=910 V 15:34:36 #38494 /GetReadyTheDischarge: Charging ... HV=939 V 15:34:36 #38494 /GetReadyTheDischarge: Charging ... HV=939 V 15:34:36 #38494 /VacuumLog: Chamber: 11.70 mPa, 30.40 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 22.01 V 15:34:37 #38494 /GetReadyTheDischarge: Charging ... HV=967 V 15:34:37 #38494 /GetReadyTheDischarge: Charging ... HV=967 V 15:34:37 #38494 /GetReadyTheDischarge: Charging ... HV=967 V 15:34:38 #38494 /GetReadyTheDischarge: Charging ... HV=994 V 15:34:38 #38494 /GetReadyTheDischarge: Bt slow PowSup 15:34:38 #38494 /ChargingResistorsAllON: Diving into .. 15:34:38 #38494 /GetReadyTheDischarge: Charging ... HV=994 V 15:34:39 #38494 /GetReadyTheDischarge: Charging ... HV=1016 V 15:34:39 #38494 /ChargingResistorsAllON: Diving into .. 15:34:39 #38494 /GetReadyTheDischarge: Bt capacitor charging finished @ 1016 V 15:34:40 #38494 /ChargingResistorsAllON: Diving into .. 15:34:40 #38494 /GetReadyTheDischarge: Ascending from .. 15:34:40 #38494 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:34:40 #38494 /VacuumLog: Chamber: 11.70 mPa, 30.40 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.01 V 15:34:42 #38494 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:34:42 #38494 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:34:44 #38494 /VacuumLog: Chamber: 11.60 mPa, 30.40 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.01 V 15:34:48 #38494 /VacuumLog: Chamber: 11.60 mPa, 30.40 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.01 V 15:34:50 #38494 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:34:51 #38494 /VacuumLog: Chamber: 11.50 mPa, 30.40 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.01 V 15:34:55 #38494 /VacuumLog: Chamber: 11.50 mPa, 30.40 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.01 V 15:34:58 #38494 /VacuumLog: Chamber: 11.50 mPa, 30.40 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.01 V 15:35:01 #38494 /Trigger: Going through .. 15:35:01 #38494 Discharge/HWTrigger: Going through .. 15:35:01 #38494 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 15:35:01 #38494 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 15:35:01 #38494 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 15:35:02 #38494 /VacuumLog: Chamber: 11.50 mPa, 30.40 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.01 V 15:35:05 #38494 /VacuumLog: Chamber: 11.50 mPa, 29.80 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.01 V 15:35:05 #38494 /ChargingResistorsAllON: Diving into .. 15:35:08 #38494 /SecurePostDischargeState: Going through .. 15:35:08 #38494 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:35:09 #38494 /VacuumLog: Chamber: 1.27 mPa, 30.40 C, ForVacuum: 2.8 Pa, Gas: NULL, GasValve: 0.00 V 15:35:13 #38494 /VacuumLog: Chamber: 1.08 mPa, 30.40 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:35:13 #38494 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:35:16 #38494 /VacuumLog: Chamber: 1.04 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:20 #38494 /VacuumLog: Chamber: 1.02 mPa, 30.50 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 15:35:23 #38494 /VacuumLog: Chamber: 1.01 mPa, 30.40 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 15:35:25 #38494 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:35:27 #38494 /VacuumLog: Chamber: 1.00 mPa, 30.50 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:31 #38494 /VacuumLog: Chamber: 1.00 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:34 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:38 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:42 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:45 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:49 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:53 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:53 #38494 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:35:56 #38494 /VacuumLog: Chamber: 0.99 mPa, 30.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 15:35:57 #38494 /DischargeFunction: General Calling FinalDischargeOperations