17:25:32 #38504 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Strip detector commissioning 17:25:32 #38504 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:25:32 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:25:34 #38504 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 17:25:34 #38504 /GetReadyTheDischarge: Going with gas pressure 12 17:25:34 #38504 /GetReadyTheDischarge: Going with gas type H 17:25:34 #38504 /GetReadyTheDischarge: Discharge with Hydrogen request 17:25:34 #38504 /GetReadyTheDischarge: Discharge with 12 mPa request 17:25:34 #38504 /GetReadyTheDischarge: Going with Bt_orientation CW 17:25:34 #38504 /GetReadyTheDischarge: Discharge with Bt CW request 17:25:34 #38504 /GetReadyTheDischarge: Going with CD_orientation CW 17:25:35 #38504 /GetReadyTheDischarge: Discharge with CD CW request 17:25:36 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 21.47 V 17:25:39 #38504 /VacuumLog: Chamber: 9.95 mPa, 31.10 C, ForVacuum: 1.85 Pa, Gas: H2, GasValve: 23.05 V 17:25:41 #38504 /GetReadyTheDischarge: Bt capacitor charging started 17:25:43 #38504 /VacuumLog: Chamber: 17.50 mPa, 30.90 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 21.22 V 17:25:46 #38504 /GetReadyTheDischarge: Cd capacitor charging started 17:25:46 #38504 /ChargingResistorsAllOFF: Diving into .. 17:25:46 #38504 /GetReadyTheDischarge: U_Bt: 1000, Hrana: 98 17:25:46 #38504 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 17:25:46 #38504 /GetReadyTheDischarge: Charging ... HV=-13 V 17:25:47 #38504 /GetReadyTheDischarge: Charging ... HV=-4 V 17:25:47 #38504 /VacuumLog: Chamber: 12.10 mPa, 31.00 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 21.30 V 17:25:47 #38504 /GetReadyTheDischarge: Charging ... HV=-4 V 17:25:47 #38504 /GetReadyTheDischarge: Charging ... HV=-4 V 17:25:48 #38504 /GetReadyTheDischarge: Charging ... HV=38 V 17:25:48 #38504 /GetReadyTheDischarge: Charging ... HV=38 V 17:25:49 #38504 /GetReadyTheDischarge: Charging ... HV=87 V 17:25:49 #38504 /GetReadyTheDischarge: Charging ... HV=87 V 17:25:50 #38504 /GetReadyTheDischarge: Charging ... HV=87 V 17:25:50 #38504 /GetReadyTheDischarge: Charging ... HV=133 V 17:25:51 #38504 /GetReadyTheDischarge: Charging ... HV=133 V 17:25:51 #38504 /VacuumLog: Chamber: 12.10 mPa, 30.90 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 21.27 V 17:25:51 #38504 /GetReadyTheDischarge: Charging ... HV=179 V 17:25:51 #38504 /GetReadyTheDischarge: Charging ... HV=179 V 17:25:52 #38504 /GetReadyTheDischarge: Charging ... HV=179 V 17:25:52 #38504 /GetReadyTheDischarge: Charging ... HV=226 V 17:25:53 #38504 /GetReadyTheDischarge: Charging ... HV=226 V 17:25:53 #38504 /GetReadyTheDischarge: Charging ... HV=270 V 17:25:54 #38504 /GetReadyTheDischarge: Charging ... HV=270 V 17:25:54 #38504 /GetReadyTheDischarge: Charging ... HV=270 V 17:25:54 #38504 /GetReadyTheDischarge: Charging ... HV=315 V , Gas: H2, GasValve: 21.27 V 17:25:55 #38504 /GetReadyTheDischarge: Charging ... HV=23 V 17:25:55 #38504 /GetReadyTheDischarge: Charging ... HV=356 V 17:25:56 #38504 /GetReadyTheDischarge: Charging ... HV=356 V 17:25:56 #38504 /GetReadyTheDischarge: Charging ... HV=356 V 17:25:57 #38504 /GetReadyTheDischarge: Charging ... HV=395 V 17:25:57 #38504 /GetReadyTheDischarge: Charging ... HV=395 V 17:25:58 #38504 /GetReadyTheDischarge: Charging ... HV=434 V 17:25:58 #38504 /GetReadyTheDischarge: Charging ... HV=434 V 17:25:58 #38504 /GetReadyTheDischarge: Charging ... HV=474 V 17:25:59 #38504 /GetReadyTheDischarge: Cd capacitor charging finished @ 474 V 17:25:59 #38504 /GetReadyTheDischarge: Charging ... HV=474 V 17:25:59 #38504 /GetReadyTheDischarge: Charging ... HV=23 V 17:26:00 #38504 /GetReadyTheDischarge: Charging ... HV=511 V 17:26:00 #38504 /GetReadyTheDischarge: Charging ... HV=511 V 17:26:01 #38504 /GetReadyTheDischarge: Charging ... HV=551 V 17:26:01 #38504 /GetReadyTheDischarge: Charging ... HV=551 V 17:26:01 #38504 /GetReadyTheDischarge: Charging ... HV=551 V 17:26:02 #38504 /GetReadyTheDischarge: Charging ... HV=589 V Gas: H2, GasValve: 21.27 V 17:26:02 #38504 /GetReadyTheDischarge: Charging ... HV=589 V 17:26:03 #38504 /GetReadyTheDischarge: Charging ... HV=625 V 17:26:03 #38504 /GetReadyTheDischarge: Charging ... HV=625 V 17:26:04 #38504 /GetReadyTheDischarge: Charging ... HV=625 V 17:26:04 #38504 /GetReadyTheDischarge: Charging ... HV=660 V 17:26:04 #38504 /GetReadyTheDischarge: Charging ... HV=660 V 17:26:05 #38504 /GetReadyTheDischarge: Charging ... HV=23 V 17:26:05 #38504 /GetReadyTheDischarge: Charging ... HV=698 V 17:26:06 #38504 /GetReadyTheDischarge: Charging ... HV=698 V 17:26:06 #38504 /GetReadyTheDischarge: Charging ... HV=731 V 17:26:07 #38504 /GetReadyTheDischarge: Charging ... HV=731 V 17:26:07 #38504 /GetReadyTheDischarge: Charging ... HV=731 V 17:26:07 #38504 /GetReadyTheDischarge: Charging ... HV=763 V 17:26:08 #38504 /GetReadyTheDischarge: Charging ... HV=763 V 17:26:08 #38504 /GetReadyTheDischarge: Charging ... HV=795 V 17:26:09 #38504 /GetReadyTheDischarge: Charging ... HV=795 V 17:26:09 #38504 /GetReadyTheDischarge: Charging ... HV=795 V 17:26:10 #38504 /GetReadyTheDischarge: Charging ... HV=826 V 17:26:10 #38504 /GetReadyTheDischarge: Charging ... HV=826 V 17:26:10 #38504 /GetReadyTheDischarge: Charging ... HV=856 V 17:26:11 #38504 /GetReadyTheDischarge: Charging ... HV=856 V 17:26:11 #38504 /GetReadyTheDischarge: Charging ... HV=856 V 17:26:12 #38504 /GetReadyTheDischarge: Charging ... HV=887 V 17:26:12 #38504 /GetReadyTheDischarge: Charging ... HV=887 V 17:26:12 #38504 /VacuumLog: Chamber: 11.50 mPa, 30.90 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 21.27 V 17:26:12 #38504 /GetReadyTheDischarge: Charging ... HV=915 V 17:26:13 #38504 /GetReadyTheDischarge: Charging ... HV=915 V 17:26:13 #38504 /GetReadyTheDischarge: Charging ... HV=915 V 17:26:14 #38504 /GetReadyTheDischarge: Charging ... HV=945 V 17:26:14 #38504 /GetReadyTheDischarge: Charging ... HV=945 V 17:26:15 #38504 /GetReadyTheDischarge: Charging ... HV=972 V 17:26:15 #38504 /GetReadyTheDischarge: Charging ... HV=972 V 17:26:15 #38504 /GetReadyTheDischarge: Charging ... HV=972 V 17:26:16 #38504 /GetReadyTheDischarge: Charging ... HV=998 V 17:26:16 #38504 /GetReadyTheDischarge: Bt slow PowSup 17:26:16 #38504 /ChargingResistorsAllON: Diving into .. 17:26:16 #38504 /VacuumLog: Chamber: 11.50 mPa, 31.00 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:16 #38504 /GetReadyTheDischarge: Charging ... HV=998 V 17:26:17 #38504 /GetReadyTheDischarge: Charging ... HV=1021 V 17:26:17 #38504 /ChargingResistorsAllON: Diving into .. 17:26:17 #38504 /GetReadyTheDischarge: Bt capacitor charging finished @ 1021 V 17:26:18 #38504 /ChargingResistorsAllON: Diving into .. 17:26:18 #38504 /GetReadyTheDischarge: Ascending from .. 17:26:18 #38504 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:26:20 #38504 /VacuumLog: Chamber: 11.50 mPa, 31.00 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:20 #38504 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:26:20 #38504 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:26:20 #38504 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 17:26:23 #38504 /VacuumLog: Chamber: 11.50 mPa, 31.00 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:27 #38504 /VacuumLog: Chamber: 11.60 mPa, 31.00 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:29 #38504 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:26:31 #38504 /VacuumLog: Chamber: 11.60 mPa, 30.90 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:34 #38504 /VacuumLog: Chamber: 11.60 mPa, 31.00 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:38 #38504 /VacuumLog: Chamber: 11.60 mPa, 30.90 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:39 #38504 /Trigger: Going through .. 17:26:39 #38504 Discharge/HWTrigger: Going through .. 17:26:39 #38504 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 17:26:39 #38504 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:26:39 #38504 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 17:26:41 #38504 /VacuumLog: Chamber: 11.60 mPa, 30.90 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 21.27 V 17:26:44 #38504 /ChargingResistorsAllON: Diving into .. 17:26:45 #38504 /VacuumLog: Chamber: 10.50 mPa, 31.00 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 0.00 V 17:26:46 #38504 /SecurePostDischargeState: Going through .. 17:26:46 #38504 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:26:49 #38504 /VacuumLog: Chamber: 1.25 mPa, 31.00 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 17:26:51 #38504 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:26:52 #38504 /VacuumLog: Chamber: 1.16 mPa, 31.00 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 17:26:56 #38504 /VacuumLog: Chamber: 1.11 mPa, 31.00 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:00 #38504 /VacuumLog: Chamber: 1.08 mPa, 31.00 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:03 #38504 /VacuumLog: Chamber: 1.06 mPa, 31.00 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:07 #38504 /VacuumLog: Chamber: 1.05 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:11 #38504 /VacuumLog: Chamber: 1.03 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:14 #38504 /VacuumLog: Chamber: 1.02 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:18 #38504 /VacuumLog: Chamber: 1.02 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:22 #38504 /VacuumLog: Chamber: 1.01 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:25 #38504 /VacuumLog: Chamber: 1.01 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:29 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:32 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:36 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:39 #38504 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:27:40 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 17:27:43 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:27:47 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:27:51 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:27:54 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:27:58 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:02 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.10 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:05 #38504 /VacuumLog: Chamber: 1.00 mPa, 30.90 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:09 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:11 #38504 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:28:13 #38504 /VacuumLog: Chamber: 1.02 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:16 #38504 /VacuumLog: Chamber: 1.00 mPa, 31.00 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:28:18 #38504 /DischargeFunction: General Calling FinalDischargeOperations