18:42:37 #38516 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Strip detector commissioning 18:42:38 #38516 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 18:42:39 #38516 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 18:42:40 #38516 /GetReadyTheDischarge: Going with gas pressure 20 18:42:40 #38516 /GetReadyTheDischarge: Going with gas type H 18:42:40 #38516 /GetReadyTheDischarge: Discharge with Hydrogen request 18:42:40 #38516 /GetReadyTheDischarge: Discharge with 20 mPa request 18:18:42:40 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: H2, GasValve: 0.00 V e: Discharge with Bt CW request 18:42:40 #38516 /GetReadyTheDischarge: Going with CD_orientation CW 18:42:40 #38516 /GetReadyTheDischarge: Discharge with CD CW request 18:42:43 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 1.8 Pa, Gas: H2, GasValve: 24.54 V 18:42:47 #38516 /GetReadyTheDischarge: Bt capacitor charging started 18:42:47 #38516 /VacuumLog: Chamber: 11.80 mPa, 31.00 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 20.95 V 18:42:51 #38516 /VacuumLog: Chamber: 23.50 mPa, 31.10 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 21.88 V 18:42:51 #38516 /GetReadyTheDischarge: Cd capacitor charging started 18:42:51 #38516 /ChargingResistorsAllOFF: Diving into .. 18:42:51 #38516 /GetReadyTheDischarge: U_Bt: 700, Hrana: 98 18:42:51 #38516 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 18:42:52 #38516 /GetReadyTheDischarge: Charging ... HV=-12 V 18:42:52 #38516 /GetReadyTheDischarge: Charging ... HV=-12 V 18:42:52 #38516 /GetReadyTheDischarge: Charging ... HV=2 V 18:42:53 #38516 /GetReadyTheDischarge: Charging ... HV=2 V 18:42:53 #38516 /GetReadyTheDischarge: Charging ... HV=48 V 18:42:54 #38516 /GetReadyTheDischarge: Charging ... HV=48 V 18:42:54 #38516 /GetReadyTheDischarge: Charging ... HV=48 V 18:42:55 #38516 /GetReadyTheDischarge: Charging ... HV=97 V , Gas: H2, GasValve: 21.62 V 18:42:55 #38516 /GetReadyTheDischarge: Charging ... HV=97 V 18:42:56 #38516 /GetReadyTheDischarge: Charging ... HV=143 V 18:42:56 #38516 /GetReadyTheDischarge: Charging ... HV=143 V 18:42:56 #38516 /GetReadyTheDischarge: Charging ... HV=0 V 18:42:57 #38516 /GetReadyTheDischarge: Charging ... HV=190 V 18:42:57 #38516 /GetReadyTheDischarge: Charging ... HV=190 V 18:42:58 #38516 /GetReadyTheDischarge: Charging ... HV=237 V 18:42:58 #38516 /GetReadyTheDischarge: Charging ... HV=237 V 18:42:59 #38516 /GetReadyTheDischarge: Charging ... HV=237 V 18:42:59 #38516 /GetReadyTheDischarge: Charging ... HV=282 V 18:42:59 #38516 /GetReadyTheDischarge: Charging ... HV=282 V 18:43:00 #38516 /GetReadyTheDischarge: Charging ... HV=326 V 18:43:00 #38516 /GetReadyTheDischarge: Charging ... HV=326 V 18:43:01 #38516 /GetReadyTheDischarge: Charging ... HV=326 V 18:43:01 #38516 /GetReadyTheDischarge: Charging ... HV=367 V 18:43:02 #38516 /VacuumLog: Chamber: 20.30 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:02 #38516 /GetReadyTheDischarge: Charging ... HV=367 V 18:43:02 #38516 /GetReadyTheDischarge: Charging ... HV=406 V 18:43:03 #38516 /GetReadyTheDischarge: Charging ... HV=406 V 18:43:03 #38516 /GetReadyTheDischarge: Charging ... HV=406 V 18:43:03 #38516 /GetReadyTheDischarge: Charging ... HV=446 V 18:43:04 #38516 /GetReadyTheDischarge: Charging ... HV=446 V 18:43:04 #38516 /GetReadyTheDischarge: Charging ... HV=484 V 18:43:05 #38516 /GetReadyTheDischarge: Charging ... HV=484 V 18:43:05 #38516 /GetReadyTheDischarge: Charging ... HV=521 V 18:43:05 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:05 #38516 /GetReadyTheDischarge: Cd capacitor charging finished @ 521 V 18:43:06 #38516 /GetReadyTheDischarge: Charging ... HV=521 V 18:43:06 #38516 /GetReadyTheDischarge: Charging ... HV=521 V 18:43:07 #38516 /GetReadyTheDischarge: Charging ... HV=559 V 18:43:07 #38516 /GetReadyTheDischarge: Charging ... HV=559 V 18:43:07 #38516 /GetReadyTheDischarge: Charging ... HV=597 V 18:43:08 #38516 /GetReadyTheDischarge: Charging ... HV=0 V 18:43:08 #38516 /GetReadyTheDischarge: Charging ... HV=597 V 18:43:09 #38516 /GetReadyTheDischarge: Charging ... HV=633 V 18:43:09 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:09 #38516 /GetReadyTheDischarge: Charging ... HV=633 V 18:43:10 #38516 /GetReadyTheDischarge: Charging ... HV=670 V 18:43:10 #38516 /GetReadyTheDischarge: Charging ... HV=670 V 18:43:10 #38516 /GetReadyTheDischarge: Charging ... HV=670 V 18:43:11 #38516 /GetReadyTheDischarge: Charging ... HV=706 V 18:43:11 #38516 /ChargingResistorsAllON: Diving into .. 18:43:11 #38516 /GetReadyTheDischarge: Bt capacitor charging finished @ 706 V 18:43:12 #38516 /ChargingResistorsAllON: Diving into .. 18:43:12 #38516 /GetReadyTheDischarge: Ascending from .. 18:43:12 #38516 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 18:43:13 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:14 #38516 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:43:14 #38516 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:43:14 #38516 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 18:43:16 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:20 #38516 /VacuumLog: Chamber: 20.20 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:22 #38516 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 18:43:24 #38516 /VacuumLog: Chamber: 20.30 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:27 #38516 /VacuumLog: Chamber: 20.30 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:31 #38516 /VacuumLog: Chamber: 20.40 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:33 #38516 /Trigger: Going through .. 18:43:33 #38516 Discharge/HWTrigger: Going through .. 18:43:33 #38516 Discharge/HWTrigger: Going with trigger Tch3 - TBt 5000 18:43:33 #38516 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 18:43:33 #38516 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 18:43:35 #38516 /VacuumLog: Chamber: 20.40 mPa, 31.10 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 21.62 V 18:43:38 #38516 /ChargingResistorsAllON: Diving into .. 18:43:38 #38516 /VacuumLog: Chamber: 21.20 mPa, 31.10 C, ForVacuum: 5.0 Pa, Gas: H2, GasValve: 21.62 V 18:43:40 #38516 /SecurePostDischargeState: Going through .. 18:43:40 #38516 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 18:43:42 #38516 /VacuumLog: Chamber: 1.52 mPa, 31.10 C, ForVacuum: 3.1 Pa, Gas: NULL, GasValve: 0.00 V 18:43:45 #38516 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 18:43:45 #38516 /VacuumLog: Chamber: 1.30 mPa, 31.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 18:43:49 #38516 /VacuumLog: Chamber: 1.22 mPa, 31.10 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 18:43:53 #38516 /VacuumLog: Chamber: 1.17 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:43:56 #38516 /VacuumLog: Chamber: 1.13 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:00 #38516 /VacuumLog: Chamber: 1.10 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:03 #38516 /VacuumLog: Chamber: 1.08 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:07 #38516 /VacuumLog: Chamber: 1.06 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:11 #38516 /VacuumLog: Chamber: 1.05 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:14 #38516 /VacuumLog: Chamber: 1.04 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:18 #38516 /VacuumLog: Chamber: 1.03 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:22 #38516 /VacuumLog: Chamber: 1.02 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:25 #38516 /VacuumLog: Chamber: 1.01 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:29 #38516 /VacuumLog: Chamber: 1.00 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:31 #38516 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 18:44:33 #38516 /VacuumLog: Chamber: 1.00 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:36 #38516 /VacuumLog: Chamber: 1.00 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:40 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:44 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:47 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:51 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.00 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:55 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:44:58 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:45:02 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:45:02 #38516 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 18:45:06 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 18:45:09 #38516 /DischargeFunction: General Calling FinalDischargeOperations 18:45:09 #38516 /VacuumLog: Chamber: 0.99 mPa, 31.10 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V