22:15:59 #38556 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 22:16:00 #38556 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 22:16:01 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:16:01 #38556 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 22:16:02 #38556 /GetReadyTheDischarge: Going with gas pressure 10 22:16:02 #38556 /GetReadyTheDischarge: Going with gas type H 22:16:02 #38556 /GetReadyTheDischarge: Discharge with Hydrogen request 22:16:02 #38556 /GetReadyTheDischarge: Discharge with 10 mPa request 22:16:02 #38556 /GetReadyTheDischarge: Discharge with Bt CW request 22:16:02 #38556 /GetReadyTheDischarge: Going with CD_orientation CW 22:16:02 #38556 /GetReadyTheDischarge: Discharge with CD CW request 22:16:04 #38556 /VacuumLog: Chamber: 0.92 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: H2, GasValve: 21.14 V 22:16:08 #38556 /VacuumLog: Chamber: 2.83 mPa, 33.20 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 23.68 V 22:16:09 #38556 /GetReadyTheDischarge: Bt capacitor charging started 22:16:12 #38556 /VacuumLog: Chamber: 9.08 mPa, 33.20 C, ForVacuum: 2.4 Pa, Gas: H2, GasValve: 24.30 V 22:16:13 #38556 /GetReadyTheDischarge: Cd capacitor charging started 22:16:14 #38556 /ChargingResistorsAllOFF: Diving into .. 22:16:14 #38556 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 22:16:14 #38556 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 22:16:14 #38556 /GetReadyTheDischarge: Charging ... HV=-9 V 22:16:14 #38556 /GetReadyTheDischarge: Charging ... HV=-9 V 22:16:15 #38556 /GetReadyTheDischarge: Charging ... HV=-9 V 22:16:15 #38556 /GetReadyTheDischarge: Charging ... HV=22 V 22:16:16 #38556 /GetReadyTheDischarge: Charging ... HV=22 V 22:16:16 #38556 /GetReadyTheDischarge: Charging ... HV=72 V 22:16:17 #38556 /GetReadyTheDischarge: Charging ... HV=72 V 22:16:17 #38556 /GetReadyTheDischarge: Charging ... HV=72 V 22:16:17 #38556 /GetReadyTheDischarge: Charging ... HV=119 V 22:16:18 #38556 /GetReadyTheDischarge: Charging ... HV=119 V 22:16:18 #38556 /GetReadyTheDischarge: Charging ... HV=166 V 22:16:19 #38556 /GetReadyTheDischarge: Charging ... HV=166 V 22:16:19 #38556 /GetReadyTheDischarge: Charging ... HV=166 V 22:16:20 #38556 /GetReadyTheDischarge: Charging ... HV=213 V 22:16:20 #38556 /GetReadyTheDischarge: Charging ... HV=213 V 22:16:20 #38556 /GetReadyTheDischarge: Charging ... HV=259 V 22:16:21 #38556 /GetReadyTheDischarge: Bt capacitor charging finished @ 259 V 22:16:21 #38556 /ChargingResistorsAllON: Diving into .. 22:16:21 #38556 /GetReadyTheDischarge: Cd capacitor charging finished @ 259 V 22:16:22 #38556 /ChargingResistorsAllON: Diving into .. 22:16:22 #38556 /GetReadyTheDischarge: Ascending from .. 22:16:22 #38556 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 22:16:22 #38556 /VacuumLog: Chamber: 9.91 mPa, 33.30 C, ForVacuum: 3.65 Pa, Gas: H2, GasValve: 22.97 V 22:16:24 #38556 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 22:16:24 #38556 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 22:16:26 #38556 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 22:16:26 #38556 /VacuumLog: Chamber: 9.82 mPa, 33.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 22.97 V 22:16:30 #38556 /VacuumLog: Chamber: 9.75 mPa, 33.20 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 22.97 V 22:16:33 #38556 /VacuumLog: Chamber: 9.68 mPa, 33.30 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 22.97 V 22:16:36 #38556 /Trigger: Going through .. 22:16:36 #38556 Discharge/HWTrigger: Going through .. 22:16:36 #38556 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 22:16:37 #38556 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 22:16:37 #38556 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 22:16:37 #38556 /VacuumLog: Chamber: 9.63 mPa, 33.20 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 22.97 V 22:16:41 #38556 /VacuumLog: Chamber: 9.55 mPa, 33.20 C, ForVacuum: 3.35 Pa, Gas: H2, GasValve: 22.97 V 22:16:41 #38556 /ChargingResistorsAllON: Diving into .. 22:16:43 #38556 /SecurePostDischargeState: Going through .. 22:16:43 #38556 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 22:16:44 #38556 /VacuumLog: Chamber: 1.16 mPa, 33.30 C, ForVacuum: 2.65 Pa, Gas: NULL, GasValve: 0.00 V 22:16:48 #38556 /VacuumLog: Chamber: 0.95 mPa, 33.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 22:16:48 #38556 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 22:16:51 #38556 /VacuumLog: Chamber: 0.92 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:16:55 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:16:59 #38556 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:16:59 #38556 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 22:17:02 #38556 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:17:06 #38556 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:17:10 #38556 /VacuumLog: Chamber: 0.90 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:17:13 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:17:17 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.15 Pa, Gas: NULL, GasValve: 0.00 V 22:17:21 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:24 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:28 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:32 #38556 /VacuumLog: Chamber: 0.91 mPa, 33.30 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:35 #38556 /VacuumLog: Chamber: 0.92 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:37 #38556 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 22:17:39 #38556 /VacuumLog: Chamber: 0.92 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:43 #38556 /VacuumLog: Chamber: 0.92 mPa, 33.20 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 22:17:44 #38556 /DischargeFunction: General Calling FinalDischargeOperations