17:44:42 #38762 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Praktika KF 17:44:43 #38762 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:44:44 #38762 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 17:44:45 #38762 /VacuumLog: Chamber: 0.87 mPa, 38.30 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 17:44:45 #38762 /GetReadyTheDischarge: Going with gas pressure 10 17:44:45 #38762 /GetReadyTheDischarge: Going with gas type H 17:44:45 #38762 /GetReadyTheDischarge: Discharge with Hydrogen requ17:44:45 #38762 /17:44:45 #38762 /GetReadyTheDischarge: Discharge with 10 mPa request etReadyTheDischarge: Discharge with Bt CW request 17:44:45 #38762 /GetReadyTheDischarge: Going with CD_orientation CW 17:44:45 #38762 /GetReadyTheDischarge: Discharge with CD CW request 17:44:48 #38762 /VacuumLog: Chamber: 1.09 mPa, 38.30 C, ForVacuum: 0.925 Pa, Gas: H2, GasValve: 22.06 V 17:44:52 #38762 /VacuumLog: Chamber: 4.31 mPa, 38.20 C, ForVacuum: 1.25 Pa, Gas: H2, GasValve: 24.32 V 17:44:52 #38762 /GetReadyTheDischarge: Bt capacitor charging started 17:44:56 #38762 /VacuumLog: Chamber: 11.80 mPa, 38.20 C, ForVacuum: 2.5 Pa, Gas: H2, GasValve: 24.53 V 17:44:56 #38762 /GetReadyTheDischarge: Cd capacitor charging started 17:44:56 #38762 /ChargingResistorsAllOFF: Diving into .. 17:44:57 #38762 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 17:44:57 #38762 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 17:44:57 #38762 /GetReadyTheDischarge: Charging ... HV=-13 V 17:44:57 #38762 /GetReadyTheDischarge: Charging ... HV=-8 V 17:44:58 #38762 /GetReadyTheDischarge: Charging ... HV=-8 V 17:44:58 #38762 /GetReadyTheDischarge: Charging ... HV=-8 V 17:44:59 #38762 /GetReadyTheDischarge: Charging ... HV=29 V 17:44:59 #38762 /GetReadyTheDischarge: Charging ... HV=29 V 17:44:59 #38762 /GetReadyTheDischarge: Charging ... HV=78 V 17:45:00 #38762 /GetReadyTheDischarge: Charging ... HV=78 V 17:45:00 #38762 /GetReadyTheDischarge: Charging ... HV=123 V 17:45:01 #38762 /GetReadyTheDischarge: Charging ... HV=23 V 17:45:01 #38762 /GetReadyTheDischarge: Charging ... HV=123 V 17:45:02 #38762 /GetReadyTheDischarge: Charging ... HV=169 V 17:45:02 #38762 /GetReadyTheDischarge: Charging ... HV=169 V 17:45:03 #38762 /GetReadyTheDischarge: Charging ... HV=216 V 17:45:03 #38762 /VacuumLog: Chamber: 10.90 mPa, 38.30 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 23.11 V 17:45:03 #38762 /GetReadyTheDischarge: Charging ... HV=216 V 17:45:03 #38762 /GetReadyTheDischarge: Charging ... HV=216 V 17:45:04 #38762 /GetReadyTheDischarge: Charging ... HV=260 V 17:45:04 #38762 /GetReadyTheDischarge: Charging ... HV=260 V 17:45:05 #38762 /GetReadyTheDischarge: Charging ... HV=304 V 17:45:05 #38762 /GetReadyTheDischarge: Charging ... HV=304 V 17:45:06 #38762 /GetReadyTheDischarge: Charging ... HV=304 V 17:45:06 #38762 /GetReadyTheDischarge: Charging ... HV=346 V 17:45:06 #38762 /GetReadyTheDischarge: Charging ... HV=346 V , Gas: H2, GasValve: 23.11 V 17:45:07 #38762 /GetReadyTheDischarge: Charging ... HV=385 V 17:45:07 #38762 /GetReadyTheDischarge: Charging ... HV=385 V 17:45:08 #38762 /GetReadyTheDischarge: Charging ... HV=423 V 17:45:08 #38762 /GetReadyTheDischarge: Charging ... HV=423 V 17:45:09 #38762 /GetReadyTheDischarge: Charging ... HV=423 V 17:45:09 #38762 /GetReadyTheDischarge: Charging ... HV=463 V 17:45:09 #38762 /GetReadyTheDischarge: Cd capacitor charging finished @ 463 V 17:45:10 #38762 /GetReadyTheDischarge: Charging ... HV=463 V 17:45:10 #38762 /GetReadyTheDischarge: Charging ... HV=500 V Gas: H2, GasValve: 23.11 V 17:45:10 #38762 /GetReadyTheDischarge: Charging ... HV=500 V 17:45:11 #38762 /GetReadyTheDischarge: Charging ... HV=500 V 17:45:11 #38762 /GetReadyTheDischarge: Charging ... HV=538 V 17:45:12 #38762 /GetReadyTheDischarge: Charging ... HV=538 V 17:45:12 #38762 /GetReadyTheDischarge: Charging ... HV=578 V 17:45:13 #38762 /GetReadyTheDischarge: Charging ... HV=578 V 17:45:13 #38762 /GetReadyTheDischarge: Charging ... HV=578 V 17:45:13 #38762 /GetReadyTheDischarge: Charging ... HV=614 V 17:45:14 #38762 /GetReadyTheDischarge: Charging ... HV=614 V , Gas: H2, GasValve: 23.11 V 17:45:14 #38762 /GetReadyTheDischarge: Charging ... HV=649 V 17:45:15 #38762 /GetReadyTheDischarge: Charging ... HV=649 V 17:45:15 #38762 /GetReadyTheDischarge: Charging ... HV=649 V 17:45:16 #38762 /GetReadyTheDischarge: Charging ... HV=686 V 17:45:16 #38762 /GetReadyTheDischarge: Charging ... HV=686 V 17:45:16 #38762 /GetReadyTheDischarge: Charging ... HV=686 V 17:45:17 #38762 /GetReadyTheDischarge: Charging ... HV=721 V 17:45:17 #38762 /GetReadyTheDischarge: Charging ... HV=721 V 17:45:18 #38762 /GetReadyTheDischarge: Charging ... HV=753 V , Gas: H2, GasValve: 23.11 V 17:45:18 #38762 /GetReadyTheDischarge: Charging ... HV=753 V 17:45:18 #38762 /GetReadyTheDischarge: Charging ... HV=753 V 17:45:19 #38762 /GetReadyTheDischarge: Charging ... HV=784 V 17:45:19 #38762 /GetReadyTheDischarge: Charging ... HV=784 V 17:45:20 #38762 /GetReadyTheDischarge: Charging ... HV=23 V 17:45:20 #38762 /GetReadyTheDischarge: Charging ... HV=815 V 17:45:20 #38762 /ChargingResistorsAllON: Diving into .. 17:45:21 #38762 /GetReadyTheDischarge: Bt capacitor charging finished @ 815 V 17:45:21 #38762 /ChargingResistorsAllON: Diving into .. 17:45:21 #38762 /GetReadyTheDischarge: Ascending from .. 17:45:21 #38762 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:45:23 #38762 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:45:23 #38762 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:45:25 #38762 /VacuumLog: Chamber: 10.30 mPa, 38.40 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.11 V 17:45:25 #38762 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:45:28 #38762 /VacuumLog: Chamber: 10.30 mPa, 38.40 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.11 V 17:45:32 #38762 /VacuumLog: Chamber: 10.20 mPa, 38.30 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.11 V 17:45:36 #38762 /VacuumLog: Chamber: 10.20 mPa, 38.40 C, ForVacuum: 3.2 Pa, Gas: H2, GasValve: 23.11 V 17:45:36 #38762 /Trigger: Going through .. 17:45:36 #38762 Discharge/HWTrigger: Going through .. 17:45:36 #38762 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 17:45:36 #38762 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:45:36 #38762 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 17:45:39 #38762 /VacuumLog: Chamber: 9.56 mPa, 38.30 C, ForVacuum: 3.05 Pa, Gas: H2, GasValve: 23.11 V 17:45:40 #38762 /ChargingResistorsAllON: Diving into .. 17:45:43 #38762 /SecurePostDischargeState: Going through .. 17:45:43 #38762 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:45:43 #38762 /VacuumLog: Chamber: 1.86 mPa, 38.30 C, ForVacuum: 2.7 Pa, Gas: NULL, GasValve: 0.00 V 17:45:47 #38762 /VacuumLog: Chamber: 1.11 mPa, 38.40 C, ForVacuum: 1.2 Pa, Gas: NULL, GasValve: 0.00 V 17:45:48 #38762 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:45:50 #38762 /VacuumLog: Chamber: 1.05 mPa, 38.40 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 17:45:54 #38762 /VacuumLog: Chamber: 1.01 mPa, 38.40 C, ForVacuum: 0.89 Pa, Gas: NULL, GasValve: 0.00 V 17:45:57 #38762 /VacuumLog: Chamber: 0.99 mPa, 38.40 C, ForVacuum: 0.895 Pa, Gas: NULL, GasValve: 0.00 V 17:46:01 #38762 /VacuumLog: Chamber: 0.97 mPa, 38.40 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 17:46:05 #38762 /VacuumLog: Chamber: 0.95 mPa, 38.40 C, ForVacuum: 0.905 Pa, Gas: NULL, GasValve: 0.00 V 17:46:07 #38762 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:46:08 #38762 /VacuumLog: Chamber: 0.94 mPa, 38.40 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:46:12 #38762 /VacuumLog: Chamber: 0.92 mPa, 38.40 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:46:16 #38762 /VacuumLog: Chamber: 0.92 mPa, 38.40 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:46:19 #38762 /VacuumLog: Chamber: 0.91 mPa, 38.40 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 17:46:23 #38762 /VacuumLog: Chamber: 0.90 mPa, 38.40 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:26 #38762 /VacuumLog: Chamber: 0.89 mPa, 38.40 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:30 #38762 /VacuumLog: Chamber: 0.89 mPa, 38.40 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:34 #38762 /VacuumLog: Chamber: 0.88 mPa, 38.40 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:37 #38762 /VacuumLog: Chamber: 0.88 mPa, 38.30 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:41 #38762 /VacuumLog: Chamber: 0.88 mPa, 38.40 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 17:46:43 #38762 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:46:45 #38762 /VacuumLog: Chamber: 0.88 mPa, 38.30 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:48 #38762 /VacuumLog: Chamber: 0.87 mPa, 38.30 C, ForVacuum: 0.915 Pa, Gas: NULL, GasValve: 0.00 V 17:46:50 #38762 /DischargeFunction: General Calling FinalDischargeOperations