10:07:51 #38892 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Dirigent service 10:07:51 #38892 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 10:07:52 #38892 /VacuumLog: Chamber: 0.95 mPa, 40.30 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 10:07:53 #38892 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 10:07:53 #38892 /GetReadyTheDischarge: Going with gas pressure 6 10:07:53 #38892 /GetReadyTheDischarge: Going with gas type H 10:07:54 #38892 /GetReadyTheDischarge: Discharge with Hydrogen request 10:07:54 #38892 /GetReadyTheDischarge: Discharge with 6 mPa request 10:07:54 #38892 /GetReadyTheDischarge: Discharge with Bt CW request 10:07:54 #38892 /GetReadyTheDischarge: Going with CD_orientation CW 10:07:54 #38892 /GetReadyTheDischarge: Discharge with CD CW request 10:07:56 #38892 /VacuumLog: Chamber: 0.95 mPa, 40.30 C, ForVacuum: 0.945 Pa, Gas: H2, GasValve: 20.43 V 10:07:59 #38892 /VacuumLog: Chamber: 1.29 mPa, 40.30 C, ForVacuum: 0.98 Pa, Gas: H2, GasValve: 21.89 V 10:08:01 #38892 /GetReadyTheDischarge: Bt capacitor charging started 10:08:03 #38892 /VacuumLog: Chamber: 1.77 mPa, 40.20 C, ForVacuum: 1.1 Pa, Gas: H2, GasValve: 22.79 V 10:08:05 #38892 /GetReadyTheDischarge: Cd capacitor charging started 10:08:05 #38892 /ChargingResistorsAllOFF: Diving into .. 10:08:05 #38892 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 10:08:05 #38892 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 10:08:06 #38892 /GetReadyTheDischarge: Charging ... HV=-13 V 10:08:06 #38892 /GetReadyTheDischarge: Charging ... HV=-7 V 10:08:06 #38892 /GetReadyTheDischarge: Charging ... HV=-7 V 10:08:07 #38892 /GetReadyTheDischarge: Charging ... HV=-7 V 10:08:07 #38892 /GetReadyTheDischarge: Charging ... HV=33 V 10:08:08 #38892 /GetReadyTheDischarge: Charging ... HV=33 V 10:08:08 #38892 /GetReadyTheDischarge: Charging ... HV=81 V 10:08:09 #38892 /GetReadyTheDischarge: Charging ... HV=81 V 10:08:09 #38892 /GetReadyTheDischarge: Charging ... HV=81 V 10:08:09 #38892 /GetReadyTheDischarge: Charging ... HV=126 V 10:08:10 #38892 /GetReadyTheDischarge: Charging ... HV=126 V 10:08:10 #38892 /VacuumLog: Chamber: 5.34 mPa, 40.20 C, ForVacuum: 2.0 Pa, Gas: H2, GasValve: 23.72 V 10:08:10 #38892 /GetReadyTheDischarge: Charging ... HV=173 V 10:08:11 #38892 /GetReadyTheDischarge: Charging ... HV=173 V 10:08:11 #38892 /GetReadyTheDischarge: Charging ... HV=173 V 10:08:12 #38892 /GetReadyTheDischarge: Charging ... HV=219 V 10:08:12 #38892 /GetReadyTheDischarge: Charging ... HV=219 V 10:08:12 #38892 /GetReadyTheDischarge: Charging ... HV=263 V 10:08:13 #38892 /GetReadyTheDischarge: Charging ... HV=263 V 10:08:13 #38892 /GetReadyTheDischarge: Charging ... HV=308 V 10:08:14 #38892 /GetReadyTheDischarge: Charging ... HV=308 V 10:08:14 #38892 /VacuumLog: Chamber: 6.70 mPa, 40.20 C, ForVacuum: 2.35 Pa, Gas: H2, GasValve: 23.72 V 10:08:14 #38892 /GetReadyTheDischarge: Charging ... HV=308 V 10:08:15 #38892 /GetReadyTheDischarge: Charging ... HV=349 V 10:08:15 #38892 /GetReadyTheDischarge: Charging ... HV=349 V 10:08:16 #38892 /GetReadyTheDischarge: Charging ... HV=16 V 10:08:16 #38892 /GetReadyTheDischarge: Charging ... HV=388 V 10:08:16 #38892 /GetReadyTheDischarge: Charging ... HV=388 V 10:08:17 #38892 /GetReadyTheDischarge: Charging ... HV=426 V 10:08:17 #38892 /GetReadyTheDischarge: Charging ... HV=426 V 10:08:18 #38892 /GetReadyTheDischarge: Charging ... HV=466 V Gas: H2, GasValve: 23.72 V 10:08:18 #38892 /GetReadyTheDischarge: Cd capacitor charging finished @ 466 V 10:08:18 #38892 /GetReadyTheDischarge: Charging ... HV=466 V 10:08:19 #38892 /GetReadyTheDischarge: Charging ... HV=502 V 10:08:19 #38892 /GetReadyTheDischarge: Charging ... HV=502 V 10:08:20 #38892 /GetReadyTheDischarge: Charging ... HV=502 V 10:08:20 #38892 /GetReadyTheDischarge: Charging ... HV=541 V 10:08:20 #38892 /GetReadyTheDischarge: Charging ... HV=541 V 10:08:21 #38892 /GetReadyTheDischarge: Charging ... HV=541 V 10:08:21 #38892 /GetReadyTheDischarge: Charging ... HV=580 V 10:08:21 #38892 /VacuumLog: Chamber: 7.78 mPa, 40.20 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 23.72 V 10:08:22 #38892 /GetReadyTheDischarge: Charging ... HV=580 V 10:08:22 #38892 /GetReadyTheDischarge: Charging ... HV=616 V 10:08:23 #38892 /GetReadyTheDischarge: Charging ... HV=616 V 10:08:23 #38892 /GetReadyTheDischarge: Charging ... HV=616 V 10:08:23 #38892 /GetReadyTheDischarge: Charging ... HV=650 V 10:08:24 #38892 /GetReadyTheDischarge: Charging ... HV=650 V 10:08:24 #38892 /GetReadyTheDischarge: Charging ... HV=688 V 10:08:25 #38892 /GetReadyTheDischarge: Charging ... HV=688 V 10:08:25 #38892 /GetReadyTheDischarge: Charging ... HV=688 V Gas: H2, GasValve: 23.72 V 10:08:25 #38892 /GetReadyTheDischarge: Charging ... HV=722 V 10:08:26 #38892 /GetReadyTheDischarge: Charging ... HV=722 V 10:08:26 #38892 /GetReadyTheDischarge: Charging ... HV=754 V 10:08:27 #38892 /GetReadyTheDischarge: Charging ... HV=754 V 10:08:27 #38892 /GetReadyTheDischarge: Charging ... HV=754 V 10:08:28 #38892 /GetReadyTheDischarge: Charging ... HV=785 V 10:08:28 #38892 /GetReadyTheDischarge: Bt slow PowSup 10:08:28 #38892 /ChargingResistorsAllON: Diving into .. 10:08:28 #38892 /GetReadyTheDischarge: Charging ... HV=785 V 10:08:29 #38892 /GetReadyTheDischarge: Charging ... HV=814 V 10:08:29 #38892 /ChargingResistorsAllON: Diving into .. 10:08:29 #38892 /GetReadyTheDischarge: Bt capacitor charging finished @ 814 V 10:08:30 #38892 /ChargingResistorsAllON: Diving into .. 10:08:30 #38892 /GetReadyTheDischarge: Ascending from .. 10:08:30 #38892 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 10:08:31 #38892 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:08:31 #38892 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:08:31 #38892 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 10:08:32 #38892 /VacuumLog: Chamber: 8.07 mPa, 40.20 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 23.72 V 10:08:36 #38892 /VacuumLog: Chamber: 8.14 mPa, 40.20 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 23.72 V 10:08:39 #38892 /VacuumLog: Chamber: 8.21 mPa, 40.20 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 23.72 V 10:08:42 #38892 /Trigger: Going through .. 10:08:42 #38892 Discharge/HWTrigger: Going through .. 10:08:42 #38892 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 10:08:42 #38892 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 10:08:42 #38892 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 10:08:43 #38892 /VacuumLog: Chamber: 8.27 mPa, 40.10 C, ForVacuum: 2.9 Pa, Gas: H2, GasValve: 23.72 V 10:08:46 #38892 /ChargingResistorsAllON: Diving into .. 10:08:47 #38892 /VacuumLog: Chamber: 8.40 mPa, 40.20 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 23.72 V 10:08:49 #38892 /SecurePostDischargeState: Going through .. 10:08:49 #38892 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 10:08:50 #38892 /VacuumLog: Chamber: 1.16 mPa, 40.20 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 10:08:54 #38892 /VacuumLog: Chamber: 0.99 mPa, 40.30 C, ForVacuum: 1.05 Pa, Gas: NULL, GasValve: 0.00 V 10:08:54 #38892 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 10:08:57 #38892 /VacuumLog: Chamber: 0.97 mPa, 40.30 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:09:01 #38892 /VacuumLog: Chamber: 0.95 mPa, 40.30 C, ForVacuum: 0.91 Pa, Gas: NULL, GasValve: 0.00 V 10:09:05 #38892 /VacuumLog: Chamber: 0.95 mPa, 40.30 C, ForVacuum: 0.92 Pa, Gas: NULL, GasValve: 0.00 V 10:09:05 #38892 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 10:09:08 #38892 /VacuumLog: Chamber: 0.94 mPa, 40.20 C, ForVacuum: 0.925 Pa, Gas: NULL, GasValve: 0.00 V 10:09:11 #38892 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 10:09:12 #38892 /VacuumLog: Chamber: 0.94 mPa, 40.20 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:09:16 #38892 /VacuumLog: Chamber: 0.94 mPa, 40.20 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V 10:09:19 #38892 /DischargeFunction: General Calling FinalDischargeOperations 10:09:19 #38892 /VacuumLog: Chamber: 0.94 mPa, 40.20 C, ForVacuum: 0.93 Pa, Gas: NULL, GasValve: 0.00 V