16:17:46 #38959 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU 16:17:46 #38959 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:17:46 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.80 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:17:48 #38959 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:17:48 #38959 /GetReadyTheDischarge: Going with gas pressure 10 16:17:48 #38959 /GetReadyTheDischarge: Going with gas type H 16:17:48 #38959 /GetReadyTheDischarge: Discharge with Hydrogen request 16:17:48 #38959 /GetReadyTheDischarge: Discharge with 10 mPa request 16:17:48 #38959 /GetReadyTheDischarge: Discharge with Bt CW request 16:17:49 #38959 /GetReadyTheDischarge: Going with CD_orientation CW 16:17:49 #38959 /GetReadyTheDischarge: Discharge with CD CW request 16:17:50 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.80 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 21.13 V 16:17:53 #38959 /VacuumLog: Chamber: 0.97 mPa, 37.80 C, ForVacuum: 1.0 Pa, Gas: H2, GasValve: 22.95 V 16:17:55 #38959 /GetReadyTheDischarge: Bt capacitor charging started 16:17:57 #38959 /VacuumLog: Chamber: 2.42 mPa, 37.80 C, ForVacuum: 1.15 Pa, Gas: H2, GasValve: 25.47 V 16:18:00 #38959 /GetReadyTheDischarge: Cd capacitor charging started 16:18:00 #38959 /ChargingResistorsAllOFF: Diving into .. 16:18:00 #38959 /GetReadyTheDischarge: U_Bt: 1150, Hrana: 98 16:18:00 #38959 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 16:18:00 #38959 /GetReadyTheDischarge: Charging ... HV=-11 V 16:18:01 #38959 /GetReadyTheDischarge: Charging ... HV=-7 V Gas: H2, GasValve: 26.37 V 16:18:01 #38959 /GetReadyTheDischarge: Charging ... HV=-7 V 16:18:02 #38959 /GetReadyTheDischarge: Charging ... HV=27 V 16:18:02 #38959 /GetReadyTheDischarge: Charging ... HV=27 V 16:18:02 #38959 /GetReadyTheDischarge: Charging ... HV=27 V 16:18:03 #38959 /GetReadyTheDischarge: Charging ... HV=76 V 16:18:03 #38959 /GetReadyTheDischarge: Charging ... HV=76 V 16:18:04 #38959 /GetReadyTheDischarge: Charging ... HV=122 V 16:18:04 #38959 /GetReadyTheDischarge: Charging ... HV=122 V 16:18:05 #38959 /GetReadyTheDischarge: Charging ... HV=122 V , Gas: H2, GasValve: 25.56 V 16:18:05 #38959 /GetReadyTheDischarge: Charging ... HV=169 V 16:18:05 #38959 /GetReadyTheDischarge: Charging ... HV=169 V 16:18:06 #38959 /GetReadyTheDischarge: Charging ... HV=215 V 16:18:06 #38959 /GetReadyTheDischarge: Charging ... HV=215 V 16:18:07 #38959 /GetReadyTheDischarge: Charging ... HV=261 V 16:18:07 #38959 /GetReadyTheDischarge: Charging ... HV=261 V 16:18:08 #38959 /GetReadyTheDischarge: Charging ... HV=261 V 16:18:08 #38959 /GetReadyTheDischarge: Charging ... HV=306 V 16:18:09 #38959 /GetReadyTheDischarge: Charging ... HV=306 V 16:18:09 #38959 /GetReadyTheDischarge: Charging ... HV=348 V 16:18:09 #38959 /GetReadyTheDischarge: Charging ... HV=348 V 16:18:10 #38959 /GetReadyTheDischarge: Charging ... HV=348 V 16:18:10 #38959 /GetReadyTheDischarge: Charging ... HV=387 V 16:18:11 #38959 /GetReadyTheDischarge: Charging ... HV=387 V 16:18:11 #38959 /GetReadyTheDischarge: Charging ... HV=426 V 16:18:11 #38959 /VacuumLog: Chamber: 18.10 mPa, 37.80 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 25.56 V 16:18:12 #38959 /GetReadyTheDischarge: Charging ... HV=426 V 16:18:12 #38959 /GetReadyTheDischarge: Charging ... HV=426 V 16:18:12 #38959 /GetReadyTheDischarge: Charging ... HV=466 V 16:18:13 #38959 /GetReadyTheDischarge: Charging ... HV=466 V 16:18:13 #38959 /GetReadyTheDischarge: Charging ... HV=503 V 16:18:14 #38959 /GetReadyTheDischarge: Charging ... HV=503 V 16:18:14 #38959 /GetReadyTheDischarge: Charging ... HV=503 V 16:18:15 #38959 /GetReadyTheDischarge: Charging ... HV=540 V 16:18:15 #38959 /GetReadyTheDischarge: Charging ... HV=540 V 16:18:15 #38959 /VacuumLog: Chamber: 18.20 mPa, 37.80 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 25.56 V 16:18:16 #38959 /GetReadyTheDischarge: Charging ... HV=576 V 16:18:16 #38959 /GetReadyTheDischarge: Charging ... HV=576 V 16:18:16 #38959 /GetReadyTheDischarge: Charging ... HV=576 V 16:18:17 #38959 /GetReadyTheDischarge: Charging ... HV=609 V 16:18:17 #38959 /GetReadyTheDischarge: Charging ... HV=609 V 16:18:18 #38959 /GetReadyTheDischarge: Charging ... HV=640 V 16:18:18 #38959 /GetReadyTheDischarge: Charging ... HV=640 V 16:18:19 #38959 /GetReadyTheDischarge: Charging ... HV=675 V 16:18:19 #38959 /GetReadyTheDischarge: Charging ... HV=675 V , Gas: H2, GasValve: 25.56 V 16:18:19 #38959 /GetReadyTheDischarge: Charging ... HV=675 V 16:18:20 #38959 /GetReadyTheDischarge: Charging ... HV=708 V 16:18:20 #38959 /GetReadyTheDischarge: Cd capacitor charging finished @ 708 V 16:18:20 #38959 /GetReadyTheDischarge: Charging ... HV=708 V 16:18:21 #38959 /GetReadyTheDischarge: Charging ... HV=738 V 16:18:21 #38959 /GetReadyTheDischarge: Charging ... HV=22 V 16:18:22 #38959 /GetReadyTheDischarge: Charging ... HV=738 V 16:18:22 #38959 /GetReadyTheDischarge: Charging ... HV=770 V 16:18:23 #38959 /GetReadyTheDischarge: Charging ... HV=770 V 16:18:23 #38959 /GetReadyTheDischarge: Charging ... HV=801 V 16:18:23 #38959 /GetReadyTheDischarge: Charging ... HV=801 V 16:18:24 #38959 /GetReadyTheDischarge: Charging ... HV=801 V 16:18:24 #38959 /GetReadyTheDischarge: Charging ... HV=833 V 16:18:25 #38959 /GetReadyTheDischarge: Charging ... HV=833 V 16:18:25 #38959 /GetReadyTheDischarge: Charging ... HV=862 V 16:18:26 #38959 /GetReadyTheDischarge: Charging ... HV=862 V 16:18:26 #38959 /GetReadyTheDischarge: Charging ... HV=862 V 16:18:26 #38959 /GetReadyTheDischarge: Charging ... HV=893 V 16:18:27 #38959 /GetReadyTheDischarge: Charging ... HV=22 V 16:18:27 #38959 /GetReadyTheDischarge: Charging ... HV=921 V 16:18:28 #38959 /GetReadyTheDischarge: Charging ... HV=921 V 16:18:28 #38959 /GetReadyTheDischarge: Charging ... HV=921 V 16:18:28 #38959 /GetReadyTheDischarge: Charging ... HV=951 V 16:18:29 #38959 /GetReadyTheDischarge: Charging ... HV=951 V 16:18:29 #38959 /GetReadyTheDischarge: Charging ... HV=951 V 16:18:30 #38959 /VacuumLog: Chamber: 18.50 mPa, 37.80 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.56 V 16:18:30 #38959 /GetReadyTheDischarge: Charging ... HV=978 V 16:18:30 #38959 /GetReadyTheDischarge: Charging ... HV=978 V 16:18:31 #38959 /GetReadyTheDischarge: Charging ... HV=1003 V 16:18:31 #38959 /GetReadyTheDischarge: Charging ... HV=1003 V 16:18:31 #38959 /GetReadyTheDischarge: Charging ... HV=1029 V 16:18:32 #38959 /GetReadyTheDischarge: Charging ... HV=1029 V 16:18:32 #38959 /GetReadyTheDischarge: Charging ... HV=1029 V 16:18:33 #38959 /GetReadyTheDischarge: Charging ... HV=1056 V 16:18:33 #38959 /GetReadyTheDischarge: Charging ... HV=1056 V 16:18:33 #38959 /VacuumLog: Chamber: 18.60 mPa, 37.80 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.56 V 16:18:34 #38959 /GetReadyTheDischarge: Charging ... HV=1056 V 16:18:34 #38959 /GetReadyTheDischarge: Charging ... HV=1081 V 16:18:34 #38959 /GetReadyTheDischarge: Charging ... HV=1081 V 16:18:35 #38959 /GetReadyTheDischarge: Charging ... HV=1104 V 16:18:35 #38959 /GetReadyTheDischarge: Charging ... HV=1104 V 16:18:36 #38959 /GetReadyTheDischarge: Charging ... HV=1104 V 16:18:36 #38959 /GetReadyTheDischarge: Charging ... HV=1127 V 16:18:37 #38959 /GetReadyTheDischarge: Charging ... HV=1127 V 16:18:37 #38959 /GetReadyTheDischarge: Charging ... HV=1148 V 16:18:37 #38959 /GetReadyTheDischarge: Bt slow PowSup 16:18:37 #38959 /ChargingResistorsAllON: Diving into .. 16:18:38 #38959 /GetReadyTheDischarge: Charging ... HV=1148 V 16:18:38 #38959 /GetReadyTheDischarge: Charging ... HV=1167 V 16:18:38 #38959 /ChargingResistorsAllON: Diving into .. 16:18:39 #38959 /GetReadyTheDischarge: Bt capacitor charging finished @ 1167 V 16:18:39 #38959 /ChargingResistorsAllON: Diving into .. 16:18:39 #38959 /GetReadyTheDischarge: Ascending from .. 16:18:39 #38959 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:18:41 #38959 /VacuumLog: Chamber: 18.70 mPa, 37.80 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.56 V 16:18:41 #38959 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:18:41 #38959 TektrMSO64-a/LogTheDeviceAction: The TunnelProbe action on stage with Arming 16:18:41 #38959 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:18:41 #38959 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 16:18:44 #38959 /VacuumLog: Chamber: 18.80 mPa, 37.80 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 25.56 V 16:18:48 #38959 /VacuumLog: Chamber: 18.90 mPa, 37.90 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.56 V 16:18:52 #38959 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:18:52 #38959 /VacuumLog: Chamber: 19.10 mPa, 37.90 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 25.56 V 16:18:55 #38959 /VacuumLog: Chamber: 19.20 mPa, 37.80 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 25.56 V 16:18:59 #38959 /VacuumLog: Chamber: 19.30 mPa, 37.80 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 25.56 V 16:19:02 #38959 /Trigger: Going through .. 16:19:02 #38959 Discharge/HWTrigger: Going through .. 16:19:02 #38959 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:19:02 #38959 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1900 16:19:02 #38959 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3100 16:19:03 #38959 /VacuumLog: Chamber: 19.50 mPa, 37.80 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 25.56 V 16:19:06 #38959 /VacuumLog: Chamber: 19.80 mPa, 37.80 C, ForVacuum: 4.65 Pa, Gas: H2, GasValve: 25.56 V 16:19:07 #38959 /ChargingResistorsAllON: Diving into .. 16:19:09 #38959 /SecurePostDischargeState: Going through .. 16:19:09 #38959 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:19:10 #38959 /VacuumLog: Chamber: 1.64 mPa, 37.90 C, ForVacuum: 3.35 Pa, Gas: NULL, GasValve: 0.00 V 16:19:14 #38959 /VacuumLog: Chamber: 1.22 mPa, 38.00 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 16:19:14 #38959 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:19:17 #38959 /VacuumLog: Chamber: 1.14 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:18 #38959 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 16:19:18 #38959 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:19:18 #38959 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:19:21 #38959 /VacuumLog: Chamber: 1.09 mPa, 38.00 C, ForVacuum: 0.98 Pa, Gas: NULL, GasValve: 0.00 V 16:19:24 #38959 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 16:19:24 #38959 /VacuumLog: Chamber: 1.06 mPa, 38.00 C, ForVacuum: 0.99 Pa, Gas: NULL, GasValve: 0.00 V 16:19:28 #38959 /VacuumLog: Chamber: 1.03 mPa, 38.00 C, ForVacuum: 0.995 Pa, Gas: NULL, GasValve: 0.00 V 16:19:32 #38959 /VacuumLog: Chamber: 1.01 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:35 #38959 /VacuumLog: Chamber: 0.99 mPa, 38.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:39 #38959 /VacuumLog: Chamber: 0.98 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:43 #38959 /VacuumLog: Chamber: 0.97 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:46 #38959 /VacuumLog: Chamber: 0.96 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:50 #38959 /VacuumLog: Chamber: 0.95 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:54 #38959 /VacuumLog: Chamber: 0.95 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:19:57 #38959 /VacuumLog: Chamber: 0.94 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:01 #38959 /VacuumLog: Chamber: 0.94 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:04 #38959 /VacuumLog: Chamber: 0.94 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:07 #38959 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:20:08 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:12 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:15 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:19 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:22 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:26 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:30 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:33 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:37 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:41 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:44 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:48 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:52 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:55 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:20:59 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:21:02 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:21:06 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:21:09 #38959 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:21:10 #38959 /VacuumLog: Chamber: 0.93 mPa, 38.00 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:21:14 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 16:21:16 #38959 /DischargeFunction: General Calling FinalDischargeOperations 16:21:17 #38959 /VacuumLog: Chamber: 0.93 mPa, 37.90 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V