16:14:09 #39306 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Exkurze 16:14:09 #39306 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:14:11 #39306 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:14:11 #39306 /VacuumLog: Chamber: 1.23 mPa, 32.70 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:14:11 #39306 /GetReadyTheDischarge: Going with gas pressure 24 16:14:11 #39306 /GetReadyTheDischarge: Going with gas type H 16:14:11 #39306 /GetReadyTheDischarge: Discharge with Hydrogen request 16:14:11 #39306 /GetReadyTheDischarge: Discharge with 24 mPa request 16:14:11 #39306 /GetReadyTheDischarge: Discharge with Bt CW request 16:14:12 #39306 /GetReadyTheDischarge: Going with CD_orientation CW 16:14:12 #39306 /GetReadyTheDischarge: Discharge with CD CW request 16:14:15 #39306 /VacuumLog: Chamber: 1.23 mPa, 32.70 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 25.77 V 16:14:18 #39306 /VacuumLog: Chamber: 53.20 mPa, 32.80 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 30.03 V 16:14:19 #39306 /GetReadyTheDischarge: Bt capacitor charging started 16:14:22 #39306 /VacuumLog: Chamber: 4.23 mPa, 32.70 C, ForVacuum: 7.15 Pa, Gas: H2, GasValve: 20.62 V 16:14:23 #39306 /GetReadyTheDischarge: Cd capacitor charging started 16:14:23 #39306 /ChargingResistorsAllOFF: Diving into .. 16:14:23 #39306 /GetReadyTheDischarge: U_Bt: 850, Hrana: 98 16:14:23 #39306 /GetReadyTheDischarge: U_Et: 500, Hrana: 98 16:14:23 #39306 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:24 #39306 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:24 #39306 /GetReadyTheDischarge: Charging ... HV=-11 V 16:14:25 #39306 /GetReadyTheDischarge: Charging ... HV=16 V 16:14:25 #39306 /GetReadyTheDischarge: Charging ... HV=16 V 16:14:26 #39306 /VacuumLog: Chamber: 8.03 mPa, 32.70 C, ForVacuum: 2.8 Pa, Gas: H2, GasValve: 26.42 V 16:14:26 #39306 /GetReadyTheDischarge: Charging ... HV=65 V 16:14:26 #39306 /GetReadyTheDischarge: Charging ... HV=65 V 16:14:26 #39306 /GetReadyTheDischarge: Charging ... HV=65 V 16:14:27 #39306 /GetReadyTheDischarge: Charging ... HV=113 V 16:14:27 #39306 /GetReadyTheDischarge: Charging ... HV=113 V 16:14:28 #39306 /GetReadyTheDischarge: Charging ... HV=160 V 16:14:28 #39306 /GetReadyTheDischarge: Charging ... HV=160 V 16:14:29 #39306 /GetReadyTheDischarge: Charging ... HV=160 V 16:14:29 #39306 /GetReadyTheDischarge: Charging ... HV=207 V 16:14:29 #39306 /VacuumLog: Chamber: 37.00 mPa, 32.70 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 27.65 V 16:14:29 #39306 /GetReadyTheDischarge: Charging ... HV=207 V 16:14:30 #39306 /GetReadyTheDischarge: Charging ... HV=253 V 16:14:30 #39306 /GetReadyTheDischarge: Charging ... HV=253 V 16:14:31 #39306 /GetReadyTheDischarge: Charging ... HV=298 V 16:14:31 #39306 /GetReadyTheDischarge: Charging ... HV=298 V 16:14:32 #39306 /GetReadyTheDischarge: Charging ... HV=298 V 16:14:32 #39306 /GetReadyTheDischarge: Charging ... HV=341 V 16:14:33 #39306 /GetReadyTheDischarge: Charging ... HV=341 V 16:14:33 #39306 /GetReadyTheDischarge: Charging ... HV=381 V Gas: H2, GasValve: 27.65 V 16:14:33 #39306 /GetReadyTheDischarge: Charging ... HV=381 V 16:14:34 #39306 /GetReadyTheDischarge: Charging ... HV=381 V 16:14:34 #39306 /GetReadyTheDischarge: Charging ... HV=420 V 16:14:35 #39306 /GetReadyTheDischarge: Charging ... HV=420 V 16:14:35 #39306 /GetReadyTheDischarge: Charging ... HV=461 V 16:14:36 #39306 /GetReadyTheDischarge: Charging ... HV=461 V 16:14:36 #39306 /GetReadyTheDischarge: Charging ... HV=461 V 16:14:36 #39306 /GetReadyTheDischarge: Charging ... HV=498 V 16:14:37 #39306 /GetReadyTheDischarge: Cd slow PowSup 16:14:37 #39306 /ChargingResistorsAllON: Diving into .. 16:14:37 #39306 /GetReadyTheDischarge: Charging ... HV=22 V 16:14:37 #39306 /GetReadyTheDischarge: Charging ... HV=533 V 16:14:38 #39306 /GetReadyTheDischarge: Cd capacitor charging finished @ 533 V 16:14:38 #39306 /GetReadyTheDischarge: Bt boost PowSup 16:14:38 #39306 /ChargingResistorsAllOFF: Diving into .. 16:14:38 #39306 /GetReadyTheDischarge: Charging ... HV=533 V 16:14:39 #39306 /GetReadyTheDischarge: Charging ... HV=544 V 16:14:39 #39306 /GetReadyTheDischarge: Charging ... HV=544 V 16:14:39 #39306 /GetReadyTheDischarge: Charging ... HV=576 V 16:14:40 #39306 /GetReadyTheDischarge: Charging ... HV=576 V 16:14:40 #39306 /GetReadyTheDischarge: Charging ... HV=576 V Gas: H2, GasValve: 27.65 V 16:14:41 #39306 /GetReadyTheDischarge: Charging ... HV=22 V 16:14:41 #39306 /GetReadyTheDischarge: Charging ... HV=612 V 16:14:41 #39306 /GetReadyTheDischarge: Charging ... HV=612 V 16:14:42 #39306 /GetReadyTheDischarge: Charging ... HV=648 V 16:14:42 #39306 /GetReadyTheDischarge: Charging ... HV=648 V 16:14:43 #39306 /GetReadyTheDischarge: Charging ... HV=686 V 16:14:43 #39306 /GetReadyTheDischarge: Charging ... HV=686 V 16:14:44 #39306 /GetReadyTheDischarge: Charging ... HV=686 V 16:14:44 #39306 /GetReadyTheDischarge: Charging ... HV=721 V 16:14:44 #39306 /GetReadyTheDischarge: Charging ... HV=721 V 16:14:45 #39306 /GetReadyTheDischarge: Charging ... HV=754 V 16:14:45 #39306 /GetReadyTheDischarge: Charging ... HV=754 V 16:14:46 #39306 /GetReadyTheDischarge: Charging ... HV=754 V 16:14:46 #39306 /GetReadyTheDischarge: Charging ... HV=787 V 16:14:47 #39306 /GetReadyTheDischarge: Charging ... HV=787 V 16:14:47 #39306 /GetReadyTheDischarge: Charging ... HV=818 V 16:14:47 #39306 /GetReadyTheDischarge: Charging ... HV=818 V 16:14:48 #39306 /GetReadyTheDischarge: Charging ... HV=818 V 16:14:48 #39306 /GetReadyTheDischarge: Charging ... HV=849 V 16:14:48 #39306 /GetReadyTheDischarge: Bt slow PowSup 16:14:48 #39306 /ChargingResistorsAllON: Diving into .. 16:14:49 #39306 /GetReadyTheDischarge: Charging ... HV=849 V 16:14:49 #39306 /GetReadyTheDischarge: Charging ... HV=878 V 16:14:50 #39306 /ChargingResistorsAllON: Diving into .. 16:14:50 #39306 /GetReadyTheDischarge: Bt capacitor charging finished @ 878 V 16:14:50 #39306 /ChargingResistorsAllON: Diving into .. 16:14:50 #39306 /GetReadyTheDischarge: Ascending from .. 16:14:50 #39306 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:14:51 #39306 /VacuumLog: Chamber: 42.90 mPa, 32.70 C, ForVacuum: 7.3 Pa, Gas: H2, GasValve: 27.65 V 16:14:52 #39306 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:14:52 #39306 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:14:52 #39306 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:14:55 #39306 /VacuumLog: Chamber: 43.30 mPa, 32.70 C, ForVacuum: 7.35 Pa, Gas: H2, GasValve: 27.65 V 16:14:58 #39306 /VacuumLog: Chamber: 43.60 mPa, 32.70 C, ForVacuum: 7.35 Pa, Gas: H2, GasValve: 27.65 V 16:15:02 #39306 /VacuumLog: Chamber: 44.00 mPa, 32.70 C, ForVacuum: 7.4 Pa, Gas: H2, GasValve: 27.65 V 16:15:03 #39306 /Trigger: Going through .. 16:15:03 #39306 Discharge/HWTrigger: Going through .. 16:15:03 #39306 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:15:03 #39306 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 0 16:15:03 #39306 Discharge/HWTrigger: Going with trigger Tch5 - Tist 5000 16:15:06 #39306 /VacuumLog: Chamber: 43.60 mPa, 32.70 C, ForVacuum: 7.4 Pa, Gas: H2, GasValve: 27.65 V 16:15:07 #39306 /ChargingResistorsAllON: Diving into .. 16:15:09 #39306 /VacuumLog: Chamber: 16.10 mPa, 32.70 C, ForVacuum: 6.9 Pa, Gas: H2, GasValve: 0.00 V 16:15:10 #39306 /SecurePostDischargeState: Going through .. 16:15:10 #39306 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:15:13 #39306 /VacuumLog: Chamber: 1.67 mPa, 32.70 C, ForVacuum: 2.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:15 #39306 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:15:17 #39306 /VacuumLog: Chamber: 1.49 mPa, 32.80 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:15:20 #39306 /VacuumLog: Chamber: 1.39 mPa, 32.70 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 16:15:24 #39306 /VacuumLog: Chamber: 1.34 mPa, 32.70 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 16:15:26 #39306 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:15:28 #39306 /VacuumLog: Chamber: 1.31 mPa, 32.70 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 16:15:31 #39306 /VacuumLog: Chamber: 1.28 mPa, 32.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:35 #39306 /VacuumLog: Chamber: 1.26 mPa, 32.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:38 #39306 /VacuumLog: Chamber: 1.25 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:42 #39306 /VacuumLog: Chamber: 1.24 mPa, 32.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:46 #39306 /VacuumLog: Chamber: 1.23 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:49 #39306 /VacuumLog: Chamber: 1.22 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:53 #39306 /VacuumLog: Chamber: 1.22 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:15:57 #39306 /VacuumLog: Chamber: 1.22 mPa, 32.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:16:00 #39306 /VacuumLog: Chamber: 1.21 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:16:02 #39306 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:16:04 #39306 /VacuumLog: Chamber: 1.21 mPa, 32.80 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:16:08 #39306 /VacuumLog: Chamber: 1.21 mPa, 32.70 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 16:16:09 #39306 /DischargeFunction: General Calling FinalDischargeOperations