14:01:47 #39309 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Exkurze NIRM, KDAIZ 14:01:48 #39309 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 14:01:49 #39309 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 14:01:50 #39309 /GetReadyTheDischarge: Going with gas pressure 10 14:01:50 #39309 /GetReadyTheDischarge: Going with gas type H 14:01:50 #39309 /GetReadyTheDischarge: Discharge with Hydrogen request 14:01:50 #39309 /GetReadyTheDischarge: Discharge with 10 mPa request 14:01:51 #39309 /VacuumLog: Chamber: 1.48 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: H2, GasValve: 0.00 V ge: Discharge with Bt CW request 14:01:50 #39309 /GetReadyTheDischarge: Going with CD_orientation CW 14:01:50 #39309 /GetReadyTheDischarge: Discharge with CD CW request 14:01:54 #39309 /VacuumLog: Chamber: 1.48 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: H2, GasValve: 22.75 V 14:01:57 #39309 /GetReadyTheDischarge: Bt capacitor charging started 14:01:58 #39309 /VacuumLog: Chamber: 2.39 mPa, 36.00 C, ForVacuum: 1.9 Pa, Gas: H2, GasValve: 24.39 V 14:02:01 #39309 /GetReadyTheDischarge: Cd capacitor charging started 14:02:01 #39309 /ChargingResistorsAllOFF: Diving into .. 14:02:02 #39309 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 14:02:02 #39309 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 14:02:02 #39309 /GetReadyTheDischarge: Charging ... HV=-15 V 14:02:02 #39309 /GetReadyTheDischarge: Charging ... HV=-10 V 14:02:03 #39309 /GetReadyTheDischarge: Charging ... HV=-10 V 14:02:03 #39309 /GetReadyTheDischarge: Charging ... HV=26 V 14:02:04 #39309 /GetReadyTheDischarge: Charging ... HV=26 V 14:02:04 #39309 /GetReadyTheDischarge: Charging ... HV=26 V 14:02:04 #39309 /GetReadyTheDischarge: Charging ... HV=74 V 14:02:05 #39309 /GetReadyTheDischarge: Charging ... HV=74 V 14:02:05 #39309 /VacuumLog: Chamber: 13.90 mPa, 36.20 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 25.41 V 14:02:05 #39309 /GetReadyTheDischarge: Charging ... HV=120 V 14:02:06 #39309 /GetReadyTheDischarge: Charging ... HV=120 V 14:02:06 #39309 /GetReadyTheDischarge: Charging ... HV=120 V 14:02:07 #39309 /GetReadyTheDischarge: Charging ... HV=166 V 14:02:07 #39309 /GetReadyTheDischarge: Charging ... HV=166 V 14:02:08 #39309 /GetReadyTheDischarge: Charging ... HV=212 V 14:02:08 #39309 /GetReadyTheDischarge: Charging ... HV=212 V 14:02:08 #39309 /GetReadyTheDischarge: Charging ... HV=212 V 14:02:09 #39309 /GetReadyTheDischarge: Charging ... HV=257 V , Gas: H2, GasValve: 25.41 V 14:02:09 #39309 /GetReadyTheDischarge: Charging ... HV=257 V 14:02:10 #39309 /GetReadyTheDischarge: Charging ... HV=301 V 14:02:10 #39309 /GetReadyTheDischarge: Charging ... HV=301 V 14:02:11 #39309 /GetReadyTheDischarge: Charging ... HV=301 V 14:02:11 #39309 /GetReadyTheDischarge: Charging ... HV=343 V 14:02:12 #39309 /GetReadyTheDischarge: Charging ... HV=343 V 14:02:12 #39309 /GetReadyTheDischarge: Charging ... HV=383 V 14:02:12 #39309 /GetReadyTheDischarge: Charging ... HV=383 V 14:02:13 #39309 /GetReadyTheDischarge: Charging ... HV=421 V Gas: H2, GasValve: 25.41 V 14:02:13 #39309 /GetReadyTheDischarge: Charging ... HV=421 V 14:02:14 #39309 /GetReadyTheDischarge: Charging ... HV=421 V 14:02:14 #39309 /GetReadyTheDischarge: Charging ... HV=460 V 14:02:14 #39309 /GetReadyTheDischarge: Cd capacitor charging finished @ 460 V 14:02:15 #39309 /GetReadyTheDischarge: Charging ... HV=460 V 14:02:15 #39309 /GetReadyTheDischarge: Charging ... HV=497 V 14:02:16 #39309 /GetReadyTheDischarge: Charging ... HV=497 V 14:02:16 #39309 /GetReadyTheDischarge: Charging ... HV=497 V 14:02:16 #39309 /GetReadyTheDischarge: Charging ... HV=536 V , Gas: H2, GasValve: 25.41 V 14:02:17 #39309 /GetReadyTheDischarge: Charging ... HV=536 V 14:02:17 #39309 /GetReadyTheDischarge: Charging ... HV=575 V 14:02:18 #39309 /GetReadyTheDischarge: Charging ... HV=575 V 14:02:18 #39309 /GetReadyTheDischarge: Charging ... HV=575 V 14:02:18 #39309 /GetReadyTheDischarge: Charging ... HV=610 V 14:02:19 #39309 /GetReadyTheDischarge: Charging ... HV=610 V 14:02:19 #39309 /GetReadyTheDischarge: Charging ... HV=645 V 14:02:20 #39309 /GetReadyTheDischarge: Charging ... HV=645 V 14:02:20 #39309 /GetReadyTheDischarge: Charging ... HV=645 V 14:02:21 #39309 /GetReadyTheDischarge: Charging ... HV=683 V 14:02:21 #39309 /GetReadyTheDischarge: Charging ... HV=683 V 14:02:21 #39309 /GetReadyTheDischarge: Charging ... HV=716 V 14:02:22 #39309 /GetReadyTheDischarge: Charging ... HV=716 V 14:02:22 #39309 /GetReadyTheDischarge: Charging ... HV=716 V 14:02:23 #39309 /GetReadyTheDischarge: Charging ... HV=749 V 14:02:23 #39309 /GetReadyTheDischarge: Charging ... HV=749 V 14:02:24 #39309 /GetReadyTheDischarge: Charging ... HV=780 V 14:02:24 #39309 /GetReadyTheDischarge: Charging ... HV=780 V 14:02:24 #39309 /GetReadyTheDischarge: Charging ... HV=780 V 14:02:25 #39309 /GetReadyTheDischarge: Charging ... HV=810 V 14:02:25 #39309 /ChargingResistorsAllON: Diving into .. 14:02:25 #39309 /GetReadyTheDischarge: Bt capacitor charging finished @ 810 V 14:02:26 #39309 /ChargingResistorsAllON: Diving into .. 14:02:26 #39309 /GetReadyTheDischarge: Ascending from .. 14:02:26 #39309 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 14:02:27 #39309 /VacuumLog: Chamber: 14.10 mPa, 36.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 25.41 V 14:02:28 #39309 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:02:28 #39309 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:02:28 #39309 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 14:02:31 #39309 /VacuumLog: Chamber: 14.20 mPa, 36.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 25.41 V 14:02:34 #39309 /VacuumLog: Chamber: 14.30 mPa, 36.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 25.41 V 14:02:38 #39309 /VacuumLog: Chamber: 14.40 mPa, 36.00 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 25.41 V 14:02:38 #39309 /Trigger: Going through .. 14:02:39 #39309 Discharge/HWTrigger: Going through .. 14:02:39 #39309 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 14:02:39 #39309 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 14:02:39 #39309 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 14:02:42 #39309 /VacuumLog: Chamber: 11.60 mPa, 36.00 C, ForVacuum: 4.55 Pa, Gas: H2, GasValve: 25.41 V 14:02:43 #39309 /ChargingResistorsAllON: Diving into .. 14:02:45 #39309 /SecurePostDischargeState: Going through .. 14:02:45 #39309 /VacuumLog: Chamber: 3.09 mPa, 36.00 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 0.00 V 14:02:46 #39309 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 14:02:49 #39309 /VacuumLog: Chamber: 1.66 mPa, 36.00 C, ForVacuum: 2.2 Pa, Gas: NULL, GasValve: 0.00 V 14:02:51 #39309 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 14:02:52 #39309 /VacuumLog: Chamber: 1.60 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:02:56 #39309 /VacuumLog: Chamber: 1.56 mPa, 36.00 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:00 #39309 /VacuumLog: Chamber: 1.53 mPa, 36.00 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:02 #39309 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 14:03:03 #39309 /VacuumLog: Chamber: 1.52 mPa, 36.00 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:07 #39309 /VacuumLog: Chamber: 1.50 mPa, 36.00 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:11 #39309 /VacuumLog: Chamber: 1.49 mPa, 36.00 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:14 #39309 /VacuumLog: Chamber: 1.49 mPa, 36.10 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:18 #39309 /VacuumLog: Chamber: 1.48 mPa, 36.10 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:22 #39309 /VacuumLog: Chamber: 1.48 mPa, 36.10 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 14:03:25 #39309 /VacuumLog: Chamber: 1.48 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:03:29 #39309 /VacuumLog: Chamber: 1.47 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:03:33 #39309 /VacuumLog: Chamber: 1.47 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:03:34 #39309 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 14:03:36 #39309 /VacuumLog: Chamber: 1.47 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:03:40 #39309 /VacuumLog: Chamber: 1.47 mPa, 36.10 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 14:03:40 #39309 /DischargeFunction: General Calling FinalDischargeOperations