15:15:01 #39405 Discharge/PrepareDischargeEnv@SHM: Command Line Request: RE session 15:15:01 #39405 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:15:03 #39405 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 15:15:04 #39405 /GetReadyTheDischarge: Going with gas pressure 10 15:15:04 #39405 /GetReadyTheDischarge: Going with gas type H 15:15:04 #39405 /GetReadyTheDischarge: Discharge with Hydrogen requ15:15:04 #39405 /15:15:04 #39405 /GetReadyTheDischarge: Discharge with 10 mPa req15:15:04 #39405 /G15:15:04 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.40 C, ForVac15:15:04 #39405 /GetReadyTheDischarge: Going with CD_orientation CW 15:15:04 #39405 /GetReadyTheDischarge: Discharge with CD CW request 15:15:07 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.40 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 21.94 V 15:15:11 #39405 /GetReadyTheDischarge: Bt capacitor charging started 15:15:11 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.40 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 24.56 V 15:15:15 #39405 /VacuumLog: Chamber: 1.46 mPa, 36.40 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 26.30 V 15:15:15 #39405 /GetReadyTheDischarge: Cd capacitor charging started 15:15:15 #39405 /ChargingResistorsAllOFF: Diving into .. 15:15:15 #39405 /GetReadyTheDischarge: U_Bt: 1150, Hrana: 98 15:15:15 #39405 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 15:15:16 #39405 /GetReadyTheDischarge: Charging ... HV=-12 V 15:15:16 #39405 /GetReadyTheDischarge: Charging ... HV=-3 V 15:15:17 #39405 /GetReadyTheDischarge: Charging ... HV=-3 V 15:15:17 #39405 /GetReadyTheDischarge: Charging ... HV=-3 V 15:15:17 #39405 /GetReadyTheDischarge: Charging ... HV=39 V 15:15:18 #39405 /GetReadyTheDischarge: Charging ... HV=39 V 15:15:18 #39405 /GetReadyTheDischarge: Charging ... HV=88 V 15:15:19 #39405 /GetReadyTheDischarge: Charging ... HV=88 V Gas: H2, GasValve: 28.36 V 15:15:19 #39405 /GetReadyTheDischarge: Charging ... HV=88 V 15:15:20 #39405 /GetReadyTheDischarge: Charging ... HV=134 V 15:15:20 #39405 /GetReadyTheDischarge: Charging ... HV=134 V 15:15:20 #39405 /GetReadyTheDischarge: Charging ... HV=180 V 15:15:21 #39405 /GetReadyTheDischarge: Charging ... HV=180 V 15:15:21 #39405 /GetReadyTheDischarge: Charging ... HV=180 V 15:15:22 #39405 /GetReadyTheDischarge: Charging ... HV=226 V 15:15:22 #39405 /GetReadyTheDischarge: Charging ... HV=226 V 15:15:23 #39405 /GetReadyTheDischarge: Charging ... HV=270 V 15:15:23 #39405 /GetReadyTheDischarge: Charging ... HV=21 V 15:15:24 #39405 /GetReadyTheDischarge: Charging ... HV=270 V 15:15:24 #39405 /GetReadyTheDischarge: Charging ... HV=315 V 15:15:24 #39405 /GetReadyTheDischarge: Charging ... HV=315 V 15:15:25 #39405 /GetReadyTheDischarge: Charging ... HV=355 V 15:15:25 #39405 /GetReadyTheDischarge: Charging ... HV=355 V 15:15:26 #39405 /GetReadyTheDischarge: Charging ... HV=394 V 15:15:26 #39405 /GetReadyTheDischarge: Charging ... HV=394 V 15:15:27 #39405 /GetReadyTheDischarge: Charging ... HV=394 V 15:15:27 #39405 /GetReadyTheDischarge: Charging ... HV=432 V 15:15:27 #39405 /GetReadyTheDischarge: Charging ... HV=432 V 15:15:28 #39405 /GetReadyTheDischarge: Charging ... HV=473 V 15:15:28 #39405 /GetReadyTheDischarge: Charging ... HV=473 V 15:15:29 #39405 /GetReadyTheDischarge: Charging ... HV=473 V 15:15:29 #39405 /GetReadyTheDischarge: Charging ... HV=508 V 15:15:29 #39405 /VacuumLog: Chamber: 21.10 mPa, 36.40 C, ForVacuum: 5.45 Pa, Gas: H2, GasValve: 28.36 V 15:15:30 #39405 /GetReadyTheDischarge: Charging ... HV=508 V 15:15:30 #39405 /GetReadyTheDischarge: Charging ... HV=544 V 15:15:31 #39405 /GetReadyTheDischarge: Charging ... HV=544 V 15:15:31 #39405 /GetReadyTheDischarge: Charging ... HV=544 V 15:15:31 #39405 /GetReadyTheDischarge: Charging ... HV=580 V 15:15:32 #39405 /GetReadyTheDischarge: Charging ... HV=580 V 15:15:32 #39405 /GetReadyTheDischarge: Charging ... HV=612 V 15:15:33 #39405 /GetReadyTheDischarge: Charging ... HV=612 V 15:15:33 #39405 /GetReadyTheDischarge: Charging ... HV=643 V Gas: H2, GasValve: 28.36 V 15:15:34 #39405 /GetReadyTheDischarge: Charging ... HV=643 V 15:15:34 #39405 /GetReadyTheDischarge: Charging ... HV=643 V 15:15:35 #39405 /GetReadyTheDischarge: Charging ... HV=678 V 15:15:35 #39405 /GetReadyTheDischarge: Charging ... HV=678 V 15:15:35 #39405 /GetReadyTheDischarge: Charging ... HV=710 V 15:15:36 #39405 /GetReadyTheDischarge: Cd capacitor charging finished @ 710 V 15:15:36 #39405 /GetReadyTheDischarge: Charging ... HV=710 V 15:15:36 #39405 /GetReadyTheDischarge: Charging ... HV=710 V 15:15:37 #39405 /GetReadyTheDischarge: Charging ... HV=740 V 15:15:37 #39405 /GetReadyTheDischarge: Charging ... HV=740 V 15:15:38 #39405 /GetReadyTheDischarge: Charging ... HV=21 V 15:15:38 #39405 /GetReadyTheDischarge: Charging ... HV=771 V 15:15:38 #39405 /GetReadyTheDischarge: Charging ... HV=771 V 15:15:39 #39405 /GetReadyTheDischarge: Charging ... HV=802 V 15:15:39 #39405 /GetReadyTheDischarge: Charging ... HV=802 V 15:15:40 #39405 /GetReadyTheDischarge: Charging ... HV=834 V 15:15:40 #39405 /GetReadyTheDischarge: Charging ... HV=834 V 15:15:41 #39405 /GetReadyTheDischarge: Charging ... HV=834 V 15:15:41 #39405 /GetReadyTheDischarge: Charging ... HV=862 V 15:15:41 #39405 /GetReadyTheDischarge: Charging ... HV=862 V 15:15:42 #39405 /GetReadyTheDischarge: Charging ... HV=893 V 15:15:42 #39405 /GetReadyTheDischarge: Charging ... HV=893 V 15:15:43 #39405 /GetReadyTheDischarge: Charging ... HV=893 V 15:15:43 #39405 /GetReadyTheDischarge: Charging ... HV=921 V 15:15:44 #39405 /GetReadyTheDischarge: Charging ... HV=921 V 15:15:44 #39405 /VacuumLog: Chamber: 24.40 mPa, 36.40 C, ForVacuum: 6.1 Pa, Gas: H2, GasValve: 28.36 V 15:15:44 #39405 /GetReadyTheDischarge: Charging ... HV=949 V 15:15:44 #39405 /GetReadyTheDischarge: Charging ... HV=949 V 15:15:45 #39405 /GetReadyTheDischarge: Charging ... HV=949 V 15:15:45 #39405 /GetReadyTheDischarge: Charging ... HV=977 V 15:15:46 #39405 /GetReadyTheDischarge: Charging ... HV=21 V 15:15:46 #39405 /GetReadyTheDischarge: Charging ... HV=1002 V 15:15:47 #39405 /GetReadyTheDischarge: Charging ... HV=1002 V 15:15:47 #39405 /GetReadyTheDischarge: Charging ... HV=1002 V 15:15:47 #39405 /GetReadyTheDischarge: Charging ... HV=1026 V 15:15:48 #39405 /VacuumLog: Chamber: 24.80 mPa, 36.40 C, ForVacuum: 6.15 Pa, Gas: H2, GasValve: 28.36 V 15:15:48 #39405 /GetReadyTheDischarge: Charging ... HV=1026 V 15:15:48 #39405 /GetReadyTheDischarge: Charging ... HV=1053 V 15:15:49 #39405 /GetReadyTheDischarge: Charging ... HV=1053 V 15:15:49 #39405 /GetReadyTheDischarge: Charging ... HV=1053 V 15:15:50 #39405 /GetReadyTheDischarge: Charging ... HV=1078 V 15:15:50 #39405 /GetReadyTheDischarge: Charging ... HV=1078 V 15:15:50 #39405 /GetReadyTheDischarge: Charging ... HV=1101 V 15:15:51 #39405 /GetReadyTheDischarge: Charging ... HV=1101 V 15:15:51 #39405 /GetReadyTheDischarge: Charging ... HV=1101 V 15:15:51 #39405 /VacuumLog: Chamber: 25.30 mPa, 36.40 C, ForVacuum: 6.25 Pa, Gas: H2, GasValve: 28.36 V 15:15:52 #39405 /GetReadyTheDischarge: Charging ... HV=1123 V 15:15:52 #39405 /GetReadyTheDischarge: Charging ... HV=21 V 15:15:53 #39405 /GetReadyTheDischarge: Charging ... HV=1123 V 15:15:53 #39405 /GetReadyTheDischarge: Charging ... HV=1143 V 15:15:53 #39405 /GetReadyTheDischarge: Bt slow PowSup 15:15:53 #39405 /ChargingResistorsAllON: Diving into .. 15:15:54 #39405 /GetReadyTheDischarge: Charging ... HV=1143 V 15:15:54 #39405 /GetReadyTheDischarge: Charging ... HV=1165 V 15:15:54 #39405 /ChargingResistorsAllON: Diving into .. 15:15:55 #39405 /GetReadyTheDischarge: Bt capacitor charging finished @ 1165 V 15:15:55 #39405 /ChargingResistorsAllON: Diving into .. 15:15:55 #39405 /VacuumLog: Chamber: 25.70 mPa, 36.40 C, ForVacuum: 6.25 Pa, Gas: H2, GasValve: 28.36 V 15:15:55 #39405 /GetReadyTheDischarge: Ascending from .. 15:15:55 #39405 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:15:57 #39405 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:15:57 #39405 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 15:15:57 #39405 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:15:59 #39405 /VacuumLog: Chamber: 26.10 mPa, 36.40 C, ForVacuum: 6.3 Pa, Gas: H2, GasValve: 28.36 V 15:16:01 #39405 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:16:02 #39405 /VacuumLog: Chamber: 26.50 mPa, 36.30 C, ForVacuum: 6.35 Pa, Gas: H2, GasValve: 28.36 V 15:16:06 #39405 /VacuumLog: Chamber: 27.00 mPa, 36.40 C, ForVacuum: 6.4 Pa, Gas: H2, GasValve: 28.36 V 15:16:10 #39405 /VacuumLog: Chamber: 27.30 mPa, 36.40 C, ForVacuum: 6.45 Pa, Gas: H2, GasValve: 28.36 V 15:16:12 #39405 /Trigger: Going through .. 15:16:12 #39405 Discharge/HWTrigger: Going through .. 15:16:12 #39405 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 15:16:12 #39405 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1900 15:16:12 #39405 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3100 15:16:13 #39405 /VacuumLog: Chamber: 27.80 mPa, 36.50 C, ForVacuum: 6.5 Pa, Gas: H2, GasValve: 28.36 V 15:16:16 #39405 /ChargingResistorsAllON: Diving into .. 15:16:17 #39405 /VacuumLog: Chamber: 28.80 mPa, 36.40 C, ForVacuum: 6.25 Pa, Gas: H2, GasValve: 0.00 V 15:16:20 #39405 /VacuumLog: Chamber: 1.64 mPa, 36.40 C, ForVacuum: 3.25 Pa, Gas: NULL, GasValve: 0.00 V 15:16:24 #39405 /VacuumLog: Chamber: 1.46 mPa, 36.40 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 15:16:28 #39405 /VacuumLog: Chamber: 1.39 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:29 #39405 /SecurePostDischargeState: Going through .. 15:16:29 #39405 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:16:31 #39405 /VacuumLog: Chamber: 1.35 mPa, 36.50 C, ForVacuum: 1.4 Pa, Gas: NULL, GasValve: 0.00 V 15:16:33 #39405 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:16:35 #39405 /VacuumLog: Chamber: 1.32 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:37 #39405 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 15:16:39 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:42 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:46 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:50 #39405 /VacuumLog: Chamber: 1.28 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:53 #39405 /VacuumLog: Chamber: 1.28 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:16:56 #39405 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 15:16:57 #39405 /VacuumLog: Chamber: 1.28 mPa, 36.40 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:01 #39405 /VacuumLog: Chamber: 1.28 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:04 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:08 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:12 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:15 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:19 #39405 /VacuumLog: Chamber: 1.29 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:23 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:26 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:30 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:34 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:37 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:41 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:45 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:48 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.50 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:52 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:55 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:17:59 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:03 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:06 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:10 #39405 /VacuumLog: Chamber: 1.32 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:14 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:17 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:19 #39405 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:18:21 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:25 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:25 #39405 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 15:18:25 #39405 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:18:26 #39405 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:18:28 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:31 #39405 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 15:18:32 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:35 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:39 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:43 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:46 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:50 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:54 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:18:57 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:01 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:05 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:08 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:12 #39405 /VacuumLog: Chamber: 1.31 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:16 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:19 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:20 #39405 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:19:23 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:26 #39405 /DischargeFunction: General Calling FinalDischargeOperations 15:19:26 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 15:19:30 #39405 /VacuumLog: Chamber: 1.30 mPa, 36.60 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V