16:41:48 #39415 Discharge/PrepareDischargeEnv@SHM: Command Line Request: RE session 16:41:48 #39415 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:41:50 #39415 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 16:41:50 #39415 /GetReadyTheDischarge: Going with gas pressure 10 16:41:50 #39415 /GetReadyTheDischarge: Going with gas type H 16:41:51 #39415 /GetReadyTheDischarge: Discharge with Hydrogen request 16:4116:41:51 #39415 /GetReadyTheDischarge: Going with Bt_orientation CW 16:41:51 #39415 /GetReadyTheDischarge: Discharge with Bt CW request 16:41:51 #39415 /GetReadyTheDischarge: Going with CD_orientation CW 16:41:51 #39415 /GetReadyTheDischarge: Discharge with CD CW request 16:41:54 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 21.94 V 16:41:58 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 24.55 V 16:41:58 #39415 /GetReadyTheDischarge: Bt capacitor charging started 16:42:01 #39415 /VacuumLog: Chamber: 1.35 mPa, 37.00 C, ForVacuum: 1.45 Pa, Gas: H2, GasValve: 26.29 V 16:42:02 #39415 /GetReadyTheDischarge: Cd capacitor charging started 16:42:02 #39415 /ChargingResistorsAllOFF: Diving into .. 16:42:02 #39415 /GetReadyTheDischarge: U_Bt: 1150, Hrana: 98 16:42:02 #39415 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 16:42:03 #39415 /GetReadyTheDischarge: Charging ... HV=-8 V 16:42:03 #39415 /GetReadyTheDischarge: Charging ... HV=-8 V 16:42:03 #39415 /GetReadyTheDischarge: Charging ... HV=-8 V 16:42:04 #39415 /GetReadyTheDischarge: Charging ... HV=22 V 16:42:04 #39415 /GetReadyTheDischarge: Charging ... HV=22 V 16:42:05 #39415 /GetReadyTheDischarge: Charging ... HV=70 V 16:42:05 #39415 /GetReadyTheDischarge: Charging ... HV=70 V 16:42:06 #39415 /GetReadyTheDischarge: Charging ... HV=70 V 16:42:06 #39415 /GetReadyTheDischarge: Charging ... HV=116 V 16:42:07 #39415 /GetReadyTheDischarge: Charging ... HV=116 V 16:42:07 #39415 /GetReadyTheDischarge: Charging ... HV=163 V 16:42:07 #39415 /GetReadyTheDischarge: Charging ... HV=163 V 16:42:08 #39415 /GetReadyTheDischarge: Charging ... HV=163 V 16:42:08 #39415 /GetReadyTheDischarge: Charging ... HV=209 V 16:42:08 #39415 /VacuumLog: Chamber: 9.22 mPa, 37.00 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 28.50 V 16:42:09 #39415 /GetReadyTheDischarge: Charging ... HV=209 V 16:42:09 #39415 /GetReadyTheDischarge: Charging ... HV=254 V 16:42:10 #39415 /GetReadyTheDischarge: Charging ... HV=254 V 16:42:10 #39415 /GetReadyTheDischarge: Charging ... HV=254 V 16:42:11 #39415 /GetReadyTheDischarge: Charging ... HV=298 V 16:42:11 #39415 /GetReadyTheDischarge: Charging ... HV=298 V 16:42:11 #39415 /GetReadyTheDischarge: Charging ... HV=341 V 16:42:12 #39415 /GetReadyTheDischarge: Charging ... HV=341 V 16:42:12 #39415 /GetReadyTheDischarge: Charging ... HV=380 V , Gas: H2, GasValve: 28.50 V 16:42:13 #39415 /GetReadyTheDischarge: Charging ... HV=380 V 16:42:13 #39415 /GetReadyTheDischarge: Charging ... HV=380 V 16:42:14 #39415 /GetReadyTheDischarge: Charging ... HV=418 V 16:42:14 #39415 /GetReadyTheDischarge: Charging ... HV=418 V 16:42:14 #39415 /GetReadyTheDischarge: Charging ... HV=459 V 16:42:15 #39415 /GetReadyTheDischarge: Charging ... HV=459 V 16:42:15 #39415 /GetReadyTheDischarge: Charging ... HV=459 V 16:42:16 #39415 /GetReadyTheDischarge: Charging ... HV=495 V 16:42:16 #39415 /GetReadyTheDischarge: Charging ... HV=495 V , Gas: H2, GasValve: 28.50 V 16:42:17 #39415 /GetReadyTheDischarge: Charging ... HV=531 V 16:42:17 #39415 /GetReadyTheDischarge: Charging ... HV=531 V 16:42:18 #39415 /GetReadyTheDischarge: Charging ... HV=531 V 16:42:18 #39415 /GetReadyTheDischarge: Charging ... HV=567 V 16:42:18 #39415 /GetReadyTheDischarge: Charging ... HV=567 V 16:42:19 #39415 /GetReadyTheDischarge: Charging ... HV=601 V 16:42:19 #39415 /GetReadyTheDischarge: Charging ... HV=601 V 16:42:20 #39415 /GetReadyTheDischarge: Charging ... HV=601 V 16:42:20 #39415 /GetReadyTheDischarge: Charging ... HV=22 V 16:42:21 #39415 /GetReadyTheDischarge: Charging ... HV=632 V 16:42:21 #39415 /GetReadyTheDischarge: Charging ... HV=666 V 16:42:21 #39415 /GetReadyTheDischarge: Charging ... HV=666 V 16:42:22 #39415 /GetReadyTheDischarge: Charging ... HV=666 V 16:42:22 #39415 /GetReadyTheDischarge: Charging ... HV=699 V 16:42:22 #39415 /GetReadyTheDischarge: Cd slow PowSup 16:42:23 #39415 /ChargingResistorsAllON: Diving into .. 16:42:23 #39415 /GetReadyTheDischarge: Charging ... HV=728 V 16:42:23 #39415 /GetReadyTheDischarge: Cd capacitor charging finished @ 728 V 16:42:23 #39415 /GetReadyTheDischarge: Bt boost PowSup 16:42:23 #39415 /ChargingResistorsAllOFF: Diving into .. 16:42:24 #39415 /GetReadyTheDischarge: Charging ... HV=728 V 16:42:24 #39415 /GetReadyTheDischarge: Charging ... HV=728 V 16:42:24 #39415 /GetReadyTheDischarge: Charging ... HV=744 V 16:42:25 #39415 /GetReadyTheDischarge: Charging ... HV=744 V 16:42:25 #39415 /GetReadyTheDischarge: Charging ... HV=774 V 16:42:26 #39415 /GetReadyTheDischarge: Charging ... HV=774 V 16:42:26 #39415 /GetReadyTheDischarge: Charging ... HV=774 V 16:42:27 #39415 /GetReadyTheDischarge: Charging ... HV=805 V 16:42:27 #39415 /GetReadyTheDischarge: Charging ... HV=805 V 16:42:27 #39415 /GetReadyTheDischarge: Charging ... HV=837 V 16:42:28 #39415 /GetReadyTheDischarge: Charging ... HV=837 V 16:42:28 #39415 /GetReadyTheDischarge: Charging ... HV=837 V 16:42:29 #39415 /GetReadyTheDischarge: Charging ... HV=865 V 16:42:29 #39415 /GetReadyTheDischarge: Charging ... HV=865 V 16:42:30 #39415 /GetReadyTheDischarge: Charging ... HV=896 V 16:42:30 #39415 /GetReadyTheDischarge: Charging ... HV=896 V 16:42:30 #39415 /GetReadyTheDischarge: Charging ... HV=896 V 16:42:31 #39415 /GetReadyTheDischarge: Charging ... HV=924 V 16:42:31 #39415 /GetReadyTheDischarge: Charging ... HV=924 V 16:42:32 #39415 /GetReadyTheDischarge: Charging ... HV=953 V 16:42:32 #39415 /GetReadyTheDischarge: Charging ... HV=953 V 16:42:33 #39415 /GetReadyTheDischarge: Charging ... HV=953 V 16:42:33 #39415 /GetReadyTheDischarge: Charging ... HV=979 V 16:42:33 #39415 /GetReadyTheDischarge: Charging ... HV=979 V 16:42:34 #39415 /GetReadyTheDischarge: Charging ... HV=1005 V 16:42:34 #39415 /VacuumLog: Chamber: 23.10 mPa, 37.00 C, ForVacuum: 5.95 Pa, Gas: H2, GasValve: 28.50 V 16:42:34 #39415 /GetReadyTheDischarge: Charging ... HV=1005 V 16:42:35 #39415 /GetReadyTheDischarge: Charging ... HV=1005 V 16:42:35 #39415 /GetReadyTheDischarge: Charging ... HV=1030 V 16:42:36 #39415 /GetReadyTheDischarge: Charging ... HV=1030 V 16:42:36 #39415 /GetReadyTheDischarge: Charging ... HV=1056 V 16:42:36 #39415 /GetReadyTheDischarge: Charging ... HV=1056 V 16:42:37 #39415 /GetReadyTheDischarge: Charging ... HV=1056 V 16:42:37 #39415 /GetReadyTheDischarge: Charging ... HV=1081 V 16:42:38 #39415 /GetReadyTheDischarge: Charging ... HV=1081 V 16:42:38 #39415 /VacuumLog: Chamber: 23.40 mPa, 37.10 C, ForVacuum: 6.0 Pa, Gas: H2, GasValve: 28.50 V 16:42:38 #39415 /GetReadyTheDischarge: Charging ... HV=1081 V 16:42:38 #39415 /GetReadyTheDischarge: Charging ... HV=1104 V 16:42:39 #39415 /GetReadyTheDischarge: Charging ... HV=1104 V 16:42:39 #39415 /GetReadyTheDischarge: Charging ... HV=1126 V 16:42:40 #39415 /GetReadyTheDischarge: Charging ... HV=1126 V 16:42:40 #39415 /GetReadyTheDischarge: Charging ... HV=1126 V 16:42:41 #39415 /GetReadyTheDischarge: Charging ... HV=1147 V 16:42:41 #39415 /GetReadyTheDischarge: Bt slow PowSup 16:42:41 #39415 /ChargingResistorsAllON: Diving into .. 16:42:41 #39415 /GetReadyTheDischarge: Charging ... HV=1147 V 16:42:42 #39415 /GetReadyTheDischarge: Charging ... HV=1167 V Gas: H2, GasValve: 28.50 V 16:42:42 #39415 /ChargingResistorsAllON: Diving into .. 16:42:42 #39415 /GetReadyTheDischarge: Bt capacitor charging finished @ 1167 V 16:42:43 #39415 /ChargingResistorsAllON: Diving into .. 16:42:43 #39415 /GetReadyTheDischarge: Ascending from .. 16:42:43 #39415 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:42:45 #39415 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:42:45 #39415 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:42:45 #39415 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_MT action on stage with Arming 16:42:45 #39415 /VacuumLog: Chamber: 24.30 mPa, 37.00 C, ForVacuum: 6.1 Pa, Gas: H2, GasValve: 28.50 V 16:42:49 #39415 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:42:49 #39415 /VacuumLog: Chamber: 24.70 mPa, 37.00 C, ForVacuum: 6.15 Pa, Gas: H2, GasValve: 28.50 V 16:42:52 #39415 /VacuumLog: Chamber: 25.00 mPa, 37.10 C, ForVacuum: 6.2 Pa, Gas: H2, GasValve: 28.50 V 16:42:56 #39415 /VacuumLog: Chamber: 25.30 mPa, 37.00 C, ForVacuum: 6.2 Pa, Gas: H2, GasValve: 28.50 V 16:42:59 #39415 /Trigger: Going through .. 16:42:59 #39415 Discharge/HWTrigger: Going through .. 16:42:59 #39415 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:42:59 #39415 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1900 16:42:59 #39415 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3100 16:43:00 #39415 /VacuumLog: Chamber: 25.60 mPa, 37.00 C, ForVacuum: 6.25 Pa, Gas: H2, GasValve: 28.50 V 16:43:03 #39415 /VacuumLog: Chamber: 25.60 mPa, 37.00 C, ForVacuum: 5.95 Pa, Gas: H2, GasValve: 28.50 V 16:43:04 #39415 /ChargingResistorsAllON: Diving into .. 16:43:07 #39415 /VacuumLog: Chamber: 2.10 mPa, 37.10 C, ForVacuum: 4.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:11 #39415 /VacuumLog: Chamber: 1.58 mPa, 37.20 C, ForVacuum: 1.9 Pa, Gas: NULL, GasValve: 0.00 V 16:43:14 #39415 /VacuumLog: Chamber: 1.86 mPa, 37.10 C, ForVacuum: 1.5 Pa, Gas: NULL, GasValve: 0.00 V 16:43:16 #39415 /SecurePostDischargeState: Going through .. 16:43:16 #39415 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:43:18 #39415 /VacuumLog: Chamber: 1.64 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:21 #39415 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:43:21 #39415 /VacuumLog: Chamber: 1.54 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:25 #39415 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 16:43:25 #39415 /VacuumLog: Chamber: 1.48 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:29 #39415 /VacuumLog: Chamber: 1.43 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:32 #39415 /VacuumLog: Chamber: 1.40 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:36 #39415 /VacuumLog: Chamber: 1.38 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:39 #39415 /VacuumLog: Chamber: 1.36 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:43 #39415 /VacuumLog: Chamber: 1.34 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:44 #39415 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 16:43:47 #39415 /VacuumLog: Chamber: 1.33 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:50 #39415 /VacuumLog: Chamber: 1.32 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:54 #39415 /VacuumLog: Chamber: 1.32 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:43:58 #39415 /VacuumLog: Chamber: 1.31 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:01 #39415 /VacuumLog: Chamber: 1.31 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:05 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:09 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:12 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:16 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:20 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:23 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:27 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:31 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:34 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:38 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:41 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:45 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:49 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:52 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:56 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:44:58 #39415 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:44:59 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:03 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:04 #39415 Papouch-St/RawDataAcquiring: Papouch-St: Start of acquiring 16:45:04 #39415 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:45:05 #39415 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:45:07 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:10 #39415 Papouch-St/RawDataAcquiring: Papouch-St: End of acquiring 16:45:10 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:14 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:18 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:21 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:25 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:29 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:32 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:36 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:39 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:43 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:47 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:50 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:54 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:58 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:45:58 #39415 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:46:01 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:46:05 #39415 /DischargeFunction: General Calling FinalDischargeOperations 16:46:05 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.10 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 16:46:09 #39415 /VacuumLog: Chamber: 1.30 mPa, 37.20 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V