11:43:37 #45866 PingAllDevices: 11:43:38 #45866 CheckAbilityToMakeDischarge: Ping OK 11:43:38 #45866 LogTheFunctionAction: The Function PrepareEnvironment@SHM on stage .. 11:43:39 #45866 PrepareDischargeEnv@SHM: ./Dirigent.sh \ \n--discharge --operation.discharge "style='standard',vacuum_shot='45832'" \\n--infrastructure.bt_ecd "U_Bt=300,t_Bt=0,U_cd=300,t_cd=500,O_Bt='CW',O_cd='CW'" \\n--infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=120,U_accel=100" \\n--infrastructure.workinggas "S_mode='U_v',S_gas='H',p_H=10,U_v=21" \\n--comment 'Master 11:43:39 #45867 PrepareDischargeEnv@SHM: Command Line Request: Replacing the capacitor from US-13.5 mF to SILKO-24 mF 11:43:39 #45867 Relay: #1@Miscellaneous (Engage12V_24V_intosystem@Miscellaneous) goes ON .. 11:43:39 #45867 Relay: #1@Miscellaneous (Engage12V_24V_intosystem@Miscellaneous) goes ON .. 11:43:39 #45867 Relay: #7@MiscII (SignalTowerOrangeGreen@MiscII) goes ON .. 11:43:39 #45867 Relay: #1@Vacuum (Majak@Vacuum) goes ON .. 11:43:39 #45867 GetReadyTheDischarge: Going with gas type H 11:43:39 #45867 Relay: #12@Vacuum (H2-pipe@Vacuum) goes ON .. 11:43:39 #45867 GetReadyTheDischarge: Going with gas pressure requested via U_v request 11:46:52 #45867 VacuumLog: p_ch=0.95/10 mPa,T_ch=34.2 C,p_fv=2.1 Pa,Gas: NULL,U_wg=0.0 V 11:46:53 #45867 GetReadyTheDischarge: Diving into .. 11:46:53 #45867 GetReadyTheDischarge: Discharge with Bt CW request 11:46:53 #45867 GetReadyTheDischarge: Discharge with CD CW request 11:43:42 #45867 Relay: #2@Miscellaneous (Preionization-Heater@Miscellaneous) goes ON .. 11:43:43 #45867 Relay: #3@PowerSupplies (ShortCircuits@PowerSupplies) goes ON .. 11:46:56 #45867 VacuumLog: p_ch=13.50/10 mPa,T_ch=34.2 C,p_fv=7.5 Pa,Gas: NULL,U_wg=21.0 V 11:43:44 #45867 Relay: #4@Miscellaneous (Preionization-Engage@Miscellaneous) goes ON .. 11:43:45 #45867 Relay: #2@PowerSupplies (PowerSupplyHVcontactor@PowerSupplies) goes ON .. 11:43:46 #45867 GetReadyTheDischarge: We have got 21 V for -1 mPa request 11:47:00 #45867 VacuumLog: p_ch=25.90/10 mPa,T_ch=34.2 C,p_fv=9.0 Pa,Gas: NULL,U_wg=21.0 V 11:47:00 #45867 GetReadyTheDischarge: Bt capacitor charging started 11:43:47 #45867 Relay: #3@PowerSupplies (ShortCircuits@PowerSupplies) goes ON .. 11:43:50 #45867 Relay: #2@PowerSupplies (PowerSupplyHVcontactor@PowerSupplies) goes ON .. 11:47:03 #45867 VacuumLog: p_ch=28.60/10 mPa,T_ch=34.1 C,p_fv=9.2 Pa,Gas: NULL,U_wg=21.0 V 11:47:05 #45867 GetReadyTheDischarge: Cd capacitor charging started 11:47:05 #45867 ChargingResistorsAllOFF: Diving into .. 11:47:05 #45867 GetReadyTheDischarge: U_Bt: 300, Hrana: 98 11:47:05 #45867 GetReadyTheDischarge: U_Et: 300, Hrana: 98 11:47:06 #45867 GetReadyTheDischarge: Charging ... HV=123 V /300 V@UBt & 300 V@Ucd 11:47:06 #45867 GetReadyTheDischarge: Charging ... HV=123 V /300 V@UBt & 300 V@Ucd 11:47:06 #45867 GetReadyTheDischarge: Charging ... HV=156 V /300 V@UBt & 300 V@Ucd 11:47:07 #45867 GetReadyTheDischarge: Charging ... HV=156 V /300 V@UBt & 300 V@Ucd 11:47:07 #45867 GetReadyTheDischarge: Charging ... HV=199 V /300 V@UBt & 300 V@Ucd 11:47:08 #45867 GetReadyTheDischarge: Charging ... HV=199 V /300 V@UBt & 300 V@Ucd 11:47:08 #45867 GetReadyTheDischarge: Charging ... HV=199 V /300 V@UBt & 300 V@Ucd 11:47:09 #45867 GetReadyTheDischarge: Charging ... HV=243 V /300 V@UBt & 300 V@Ucd 11:47:09 #45867 GetReadyTheDischarge: Charging ... HV=243 V /300 V@UBt & 300 V@Ucd 11:47:10 #45867 GetReadyTheDischarge: Charging ... HV=284 V /300 V@UBt & 300 V@Ucd 11:47:10 #45867 GetReadyTheDischarge: Charging ... HV=284 V /300 V@UBt & 300 V@Ucd 11:47:10 #45867 VacuumLog: p_ch=30.10/10 mPa,T_ch=34.3 C,p_fv=9.3 Pa,Gas: NULL,U_wg=21.0 V 11:47:11 #45867 GetReadyTheDischarge: Charging ... HV=326 V /300 V@UBt & 300 V@Ucd 11:47:11 #45867 ChargingResistorsAllON: Diving into .. 11:47:11 #45867 GetReadyTheDischarge: Bt capacitor charging finished @ 326 V 11:47:11 #45867 ChargingResistorsAllON: Diving into .. erSupplies) goes OFF .. 11:47:12 #45867 GetReadyTheDischarge: Cd capacitor charging finished @ 326 V 11:47:12 #45867 ChargingResistorsAllON: Diving into .. 11:47:13 #45867 GetReadyTheDischarge: Ascending from .. 11:44:00 #45867 Relay: #8@MiscII (SignalTowerRed@MiscII) goes ON .. 11:44:00 #45867 LogTheDeviceAction: The TektrMSO56-a.sh action on stage with Arming 11:47:14 #45867 VacuumLog: p_ch=30.40/10 mPa,T_ch=34.2 C,p_fv=9.3 Pa,Gas: NULL,U_wg=21.0 V 11:47:17 #45867 VacuumLog: p_ch=30.80/10 mPa,T_ch=34.2 C,p_fv=9.4 Pa,Gas: NULL,U_wg=21.0 V 11:47:21 #45867 VacuumLog: p_ch=31.10/10 mPa,T_ch=34.3 C,p_fv=9.4 Pa,Gas: NULL,U_wg=21.0 V 11:47:24 #45867 VacuumLog: p_ch=31.20/10 mPa,T_ch=34.3 C,p_fv=9.5 Pa,Gas: NULL,U_wg=21.0 V 11:47:26 #45867 Trigger: Going through .. 11:47:26 #45867 HWTrigger: Going through .. 11:47:26 #45867 HWTrigger: Going with trigger Tch3 - TBt 0 11:47:26 #45867 HWTrigger: Going with trigger Tch4 - Tcd 500 11:47:28 #45867 VacuumLog: p_ch=31.10/10 mPa,T_ch=34.1 C,p_fv=9.5 Pa,Gas: NULL,U_wg=21.0 V 11:44:15 #45867 SecurePostDischargeState: Going through .. 11:44:15 #45867 Relay: #2@PowerSupplies (PowerSupplyHVcontactor@PowerSupplies) goes OFF .. 11:44:15 #45867 Relay: #4@Miscellaneous (Preionization-Engage@Miscellaneous) goes OFF .. 11:44:15 #45867 Relay: #2@Miscellaneous (Preionization-Heater@Miscellaneous) goes OFF .. 11:44:15 #45867 Relay: #1@Miscellaneous (Engage12V_24V_intosystem@Miscellaneous) goes OFF .. 11:44:15 #45867 Relay: #3@PowerSupplies (ShortCircuits@PowerSupplies) goes OFF .. 11:44:15 #45867 Relay: #1@Miscellaneous (Engage12V_24V_intosystem@Miscellaneous) goes OFF .. 11:44:15 #45867 Relay: #1@Vacuum (Majak@Vacuum) goes OFF .. 11:44:16 #45867 Relay: #7@MiscII (SignalTowerOrangeGreen@MiscII) goes OFF .. 11:44:16 #45867 Relay: #3@Miscellaneous (Preionization-Shortcut@Miscellaneous) goes OFF .. 11:44:16 #45867 Relay: #8@MiscII (SignalTowerRed@MiscII) goes OFF .. 11:44:16 #45867 Relay: #2@PowerSupplies (PowerSupplyHVcontactor@PowerSupplies) goes OFF .. 11:47:29 #45867 ChargingResistorsAllON: Diving into .. 11:44:17 #45867 Relay: #12@Vacuum (H2-pipe@Vacuum) goes OFF .. 11:44:17 #45867 Relay: #13@Vacuum (He-pipe@Vacuum) goes OFF .. 11:44:17 #45867 Relay: #12@Vacuum (H2-pipe@Vacuum) goes OFF .. 11:44:18 #45867 Relay: #13@Vacuum (He-pipe@Vacuum) goes OFF .. 11:44:18 #45867 Relay: #3@PowerSupplies (ShortCircuits@PowerSupplies) goes OFF .. 11:47:32 #45867 VacuumLog: p_ch=4.44/10 mPa,T_ch=34.2 C,p_fv=4.2 Pa,Gas: NULL,U_wg=0.0 V 11:47:35 #45867 VacuumLog: p_ch=1.53/10 mPa,T_ch=34.3 C,p_fv=2.1 Pa,Gas: NULL,U_wg=0.0 V 11:47:37 #45867 SecurePostDischargeState: Going through .. 11:47:39 #45867 VacuumLog: p_ch=1.30/10 mPa,T_ch=34.3 C,p_fv=1.9 Pa,Gas: NULL,U_wg=0.0 V 11:47:42 #45867 VacuumLog: p_ch=1.23/10 mPa,T_ch=34.2 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:47:46 #45867 VacuumLog: p_ch=1.19/10 mPa,T_ch=34.3 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:47:49 #45867 VacuumLog: p_ch=1.15/10 mPa,T_ch=34.2 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:47:53 #45867 VacuumLog: p_ch=1.12/10 mPa,T_ch=34.2 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:47:56 #45867 VacuumLog: p_ch=1.10/10 mPa,T_ch=34.3 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:48:00 #45867 VacuumLog: p_ch=1.08/10 mPa,T_ch=34.2 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:48:04 #45867 VacuumLog: p_ch=1.06/10 mPa,T_ch=34.3 C,p_fv=2.0 Pa,Gas: NULL,U_wg=0.0 V 11:48:07 #45867 VacuumLog: p_ch=1.04/10 mPa,T_ch=34.1 C,p_fv=2.1 Pa,Gas: NULL,U_wg=0.0 V 11:48:11 #45867 VacuumLog: p_ch=1.03/10 mPa,T_ch=34.3 C,p_fv=2.1 Pa,Gas: NULL,U_wg=0.0 V