Automatic mode activated. Input configuration: Setting.json Output configuration: SettingOut.json Shot number is: 0 List of active spectrometers from JSON (5): 0 HR+C1886 alias IRVISUV 1 HR+C1834 alias Halpha 2 HR+C0732 alias VIS 3 HR+C2729 alias IR 4 HR2+C1103 alias UV Connected to spectrometer [0] Spectrometer[0] model: HR2000PLUS Spectrometer[0] serial number: HR2+C1103 Connected to spectrometer [1] Spectrometer[1] model: HR2000PLUS Spectrometer[1] serial number: HR+C1834 Connected to spectrometer [2] Spectrometer[2] model: HR2000PLUS Spectrometer[2] serial number: HR+C0732 Connected to spectrometer [3] Spectrometer[3] model: HR2000PLUS Spectrometer[3] serial number: HR+C2729 Connected to spectrometer [4] Spectrometer[4] model: HR2000PLUS Spectrometer[4] serial number: HR+C1886 Setting spectrometer HR+C1886 (IRVISUV) Firmware: 12344 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C1834 (Halpha) Firmware: 12344 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C0732 (VIS) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR+C2729 (IR) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Setting spectrometer HR2+C1103 (UV) Firmware: 12345 High Delay is 0 (set is 0), Low Delay is 1000 (set is 1000) Spectrometer strobe is enabled Setting integration time: Trigger mode is Software (0) Integration time is 2000 us Spectrum length is 2048 Specta count is 20 Spectrum was acquired to set spectrometer Trigger mode is Hardware Done Collecting spectra Acquisition statistic for spectrometer HR+C1886 (IRVISUV) Temperature: 32.4354 °C Average time: 2.09994 ms Delay relative to the first finished spectrometer: 0 ms Acquisition statistic for spectrometer HR+C1834 (Halpha) Temperature: 32.4979 °C Average time: 1.99659 ms Delay relative to the first finished spectrometer: 0.015251 ms Acquisition statistic for spectrometer HR+C0732 (VIS) Temperature: 32.5604 °C Average time: 2.21633 ms Delay relative to the first finished spectrometer: 0.015898 ms Acquisition statistic for spectrometer HR+C2729 (IR) Temperature: 31.3105 °C Average time: 2.21571 ms Delay relative to the first finished spectrometer: -0.011429 ms Acquisition statistic for spectrometer HR2+C1103 (UV) Temperature: 31.998 °C Average time: 2.001 ms Delay relative to the first finished spectrometer: -6e-06 ms Saving output configuration JSON to SettingOut.json