The session survey for the 25-04-24

(psql command: SELECT shot_no,"X_discharge_command" FROM operation.discharges WHERE session_id LIKE "48698 %" ORDER BY shot_no ASC LIMIT 200)

Mission="Fast Ion Temperature Measurements"

Staff="P. Macha, M. Tunkl, V. Sedmidubský, T. Brezina & Dirigent"

#48698 (25-04-24 10:21:56)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=400,t_Bt=0,O_Bt='CW',U_cd=350,t_cd=2000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='p_wg',S_gas='He',p_H=20,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,0;6000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --diagnostics.langballpenprobe "r_lp_tip='80',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6',U_lp='-1',R_lp_isat='-1'" --comment "Master test"




























#48699 (25-04-24 10:25:14)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=350,t_cd=2000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='p_wg',S_gas='He',p_H=20,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,0;6000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --diagnostics.langballpenprobe "r_lp_tip='50',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6',U_lp='-1',R_lp_isat='-1'" --comment "Master test"




























#48700 (25-04-24 10:42:09)     ./Dirigent.sh --discharge --operation.discharge "style='standard'" --infrastructure.bt_ecd "U_Bt=800,t_Bt=0,O_Bt='CW',U_cd=350,t_cd=2000,O_cd='CW'" --infrastructure.preionization "S_device='HotCathode',SW_main='on',U_heater=100,U_accel=100" --infrastructure.workinggas "S_mode='p_wg',S_gas='He',p_H=20,U_v=0" --infrastructure.positionstabilization "main_switch='on',radial_switch='on',radial_waveform='1000,0;2000,-5;5000,0;6000,-20;30000,0',vertical_switch='on',vertical_waveform='1000,0;2000,-5;7000,-10;8000,-20;30000,0'" --diagnostics.langballpenprobe "r_lp_tip='50',S_mode_lp='float',R_lp_div_osc='10e3',R_lp_div_nosc='1e6',R_bpp_div_osc='10e3',R_bpp_div_nosc='1e6',U_lp='-1',R_lp_isat='-1'" --comment "BPP DC 50 mm 0 V"