Tokamak GOLEM - Shot Database - 11086

[Template source]
[WebLog]
Date: 2013-02-28 - 20:30:48
Session:StrayFields [new]
Comment: opakujeme pro jiny proud komorou

Machine failure: Failure (BtMax) < 0.01T);

    Basic parameters: (compare)

  • Gas pressure pch:0.83->0.83 mPa (request: 15 mPa) WIKI
  • Working gas: None
  • Preionization: OFF
  • Chamber temperature: N/A C
  • CBt capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • CBD capacitors changed to: 0 V, triggered 8.0 ms WIKI
  • CCD capacitors changed to: 300 V, triggered 5.0 ms WIKI
  • CST capacitors changed to: 0 V, triggered 5.0 ms WIKI
  • Probability of breakdown: 0% WIKI
  • Time since session beginning: 0:31:27 h
WIKI