Fri Nov 22 15:01:24 CET 2013 ============== action: acquisition ======================= Frimake: *** No rule to make target `acquisition'. Stop. real 0m0.001s user 0m0.001s sys 0m0.000s real 0m0.002s user 0m0.001s sys 0m0.000s Fri Nov 22 15:01:24 CET 2013 ============== action: clean ======================= === acquisition done === Time: .0041s make: *** No rule to make target `clean'. Stop. Fri Nov 22 15:01:24 CET 2013 ============== action: analysis ======================= make: Entering directory `/golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON' make: *** No rule to make target `clean'. Stop. make: Leaving directory `/golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON' real 0m0.001s user 0m0.001s sys 0m0.000s === analysis done === Time: .0024s === plots === Time: .0336s Fri Nov 22 15:01:42 CET 2013 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON Spectrometer - impurity content calculation including time 0.389137983322 Loaded data of HR+C1886 loaded data calc inst fun calc inst fun finished standart chi2 22.9633702148 3.9434289438 [ 1. 0.9299 13.6749 19.5944 20.8121 17.7909 0.8967 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. 1. ] 3.9434289438 [ 0.9965 2.1503 4.1877 15.7052 15.3376 10.8188 5.2678 2.6946 5.2547 0.8252 5.2201 0.604 ] CalcProjections done chi2 temp: 8.63045762005 chi2 dens: 54.8254189444 fmin_bfgs ion H concentration = 0.00 ion O concentration = 0.03 ion He concentration = 0.01 ion C concentration = 0.00 ion N concentration = 0.05 ion M1 concentration = 0.68 ion MIV concentration = 0.42 flattop temperatute 27.1 chi2 temp: 8.63045762005 chi2 dens: 54.8254189444 including time 0.326920032501 no electron temperature /usr/lib64/python2.7/site-packages/numpy/core/_methods.py:57: RuntimeWarning: invalid value encountered in double_scalars ret = ret / float(rcount) /golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON/IDA.py:174: RuntimeWarning: divide by zero encountered in double_scalars amplitude[i] = sum(spect)/sum(photod) /golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON/IDA.py:206: RuntimeWarning: invalid value encountered in multiply photoData[i] *= amplitude[i] /golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON/IDA.py:209: RuntimeWarning: invalid value encountered in multiply photod[:] = interp(photoT,photoT+shift,photod )*amplitude[i] /usr/lib64/python2.7/site-packages/numpy/lib/function_base.py:993: RuntimeWarning: invalid value encountered in subtract return a[slice1]-a[slice2] including time 0.325742006302 Loaded data of HR+C1886 photodiode alpha was not found IDA start Traceback (most recent call last): File "main.py", line 602, in main() File "main.py", line 593, in main IntegLightAnalyz(wavelength,plasma_start,plasma_end, SpectrometerData,PhotodiodesData) File "/golem/database/operation/tasks/Experiments/BreakdownStudies/General/221113_1458/150028/analysis/Radiation/1212Impurities_TO.ON/IDA.py", line 296, in IntegLightAnalyz chi2 = norm(T*g-b)**2/len(b) File "/usr/lib64/python2.7/site-packages/scipy/linalg/misc.py", line 116, in norm a = np.asarray_chkfinite(a) File "/usr/lib64/python2.7/site-packages/numpy/lib/function_base.py", line 590, in asarray_chkfinite "array must not contain infs or NaNs") ValueError: array must not contain infs or NaNs real 0m11.523s user 0m10.997s sys 0m0.350s === postanalysis === Time: 11.52s