Čt lis 27 18:03:57 CET 2014 ============== action: acquisition ======================= real 0m0.001s user 0m0.001s sys 0m0.000s === acquisition done === Time: .0020s Čt lis 27 18:03:57 CET 2014 ============== action: analysis ======================= Performing advanced discharge analysis confinent time failed Loading of constant failed: /golem/database/operation/shots/17794/diagnostics/Microwaves/0712Interferometer.ON/results/electron_density_mean error: [Errno 2] No such file or directory: '/golem/database/operation/shots/17794/diagnostics/Microwaves/0712Interferometer.ON/results/electron_density_mean' real 0m0.699s user 0m0.648s sys 0m0.042s === analysis done === Time: .7000s ČtČt lis 27 18:03:59 CET 2014 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Experiments/HTS/QuenchProtectionStudies/271114_1717/180234/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis main.py:70: RuntimeWarning: invalid value encountered in less ind_plasma = (tvec > start) & ( tvec < end) main.py:70: RuntimeWarning: invalid value encountered in greater ind_plasma = (tvec > start) & ( tvec < end) real 0m0.826s user 0m0.700s sys 0m0.056s Čt lis 27 18:03:59 CET 2014 ============== action: clean ======================= make: *** No rule to make target `clean'. Stop. make: Entering directory `/golem/database/operation/tasks/Experiments/HTS/QuenchProtectionStudies/271114_1717/180234/analysis/Basics/0612AdvancedAnalysis.ON' make: *** No rule to make target `clean'. Stop. make: Leaving directory `/golem/database/operation/tasks/Experiments/HTS/QuenchProtectionStudies/271114_1717/180234/analysis/Basics/0612AdvancedAnalysis.ON' === plots === Time: ,8312s main.py:70: RuntimeWarning: invalid value encountered in less ind_plasma = (tvec > start) & ( tvec < end) main.py:70: RuntimeWarning: invalid value encountered in greater ind_plasma = (tvec > start) & ( tvec < end) real 0m0.901s user 0m0.693s sys 0m0.052s === postanalysis === Time: ,9267s Čt lis 27 18:04:15 CET 2014 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Experiments/HTS/QuenchProtectionStudies/271114_1717/180234/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis main.py:70: RuntimeWarning: invalid value encountered in less ind_plasma = (tvec > start) & ( tvec < end) main.py:70: RuntimeWarning: invalid value encountered in greater ind_plasma = (tvec > start) & ( tvec < end) real 0m0.451s user 0m0.385s sys 0m0.032s === postanalysis === Time: ,4528s