Flukes

[Template source] [Log]

Graphs (signal was smoothed !!): [Source]

Flukes


Fluke 0 - Current drive primary winding current

  • Range: +- 600.0 A
  • Sensitivity: 5.0 mV / 1A

Fluke 1 - Toroidal magnetic field coils current

  • Range: +- 6000.0 A
  • Sensitivity: 0.5 mV / 1A

Fluke 2 - Breakdown primary winding current

  • Range: +- 600.0 A
  • Sensitivity: 5.0 mV / 1A

Fluke 3 - Stabilization horizont. mag. field coils current

  • Range: +- 600.0 A
  • Sensitivity: 5.0 mV / 1A

Fluke 4 - Stabilization vert. mag. field coils current

  • Range: +- 600.0 A
  • Sensitivity: 5.0 mV / 1A

Fluke 5 - Misc current

  • Range: +- 600.0 A
  • Sensitivity: 5.0 mV / 1A

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

current_breakdown_coils (txt,xls,img,...) I_breakdown_coils Current [A] Current in breakdown coils
current_cd_coils (txt,xls,img,...) I_current_drive_coils Current [A] Current in current drive coils
current_stabilization_coils (txt,xls,img,...) I_stabilization_coils Current [A] Current in stabilization coils
current_toroidal_coils (txt,xls,img,...) I_toroidal_coils Current [A] Current in toroidal coils

Menu

Navigation