Tokamak GOLEM - Shot Database - 22978

[Template source]
[WebLog]
Date: 2017-01-17 - 10:40:41
Session: SessionPreparation/2017/
Comment: GraduateSchoolEvent - Discharge comment; groep 3 hogere druk, rest zelfd

    Basic parameters: (compare)

  • Gas pressure pch:0.25->11.84 mPa (request: 12 mPa) WIKI
  • Working gas: H
  • Preionization: Upper el. gun
  • Chamber temperature: 22.90 C
  • CBt capacitors charged to: 1100 V, triggered 5.0 ms WIKI
  • CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors charged to: 600 V, triggered 9.5 ms WIKI
  • CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • Max saturation of iron core transformator: 85% WIKI
  • Probability of breakdown: 97% WIKI
  • Time since session beginning: 1:32:09 h

    Plasma parameters:

WIKI
WIKI
WIKI
WIKI
WIKI

Data Acquisition Systems (DAS):


TektronixDPO

NIstandard

Papouch_St

NIoctopus

Diagnostics:


Interferometer

Spectrometer

FastCamera

HXR

Analysis:


ShotHomepage

AdvancedAnalysis

Students:

Guests:

Acknowledgement:


Thanks to the specific help and

Diagnostics

Analysis

DAS

Vacuum log

Other

Navigation