Thu Oct 12 20:01:58 CEST 2017 ============== action: acquisition ======================= real 0m0.001s user 0m0.000s sys 0m0.000s === acquisition done === Time: .0019s Thu Oct 12 20:01:58 CEST 2017 ============== action: analysis ======================= Performing advanced discharge analysis I 0.00446425 B 0.33831 P 21.5502 n 0.0 R 0.4 Aspect 0.25 confinent time = 0.0 real 0m0.778s user 0m0.736s sys 0m0.036s === analysis done === Time: .7790s Thu Oct 12 20:01:59 CEST 2017 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Training/2017/121017_1955/195934/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis Thumain.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan main.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan convert: Ignoring bad adaptive filter type `plot_2.png' @ warning/png.c/MagickPNGWarningHandler/1669. convert: IDAT: CRC error `plot_2.png' @ error/png.c/MagickPNGErrorHandler/1643. convert: corrupt image `plot_2.png' @ error/png.c/ReadPNGImage/3973. convert: no images defined `plot_2.png' @ error/convert.c/ConvertImageCommand/3210. /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... convert: improper image header `plot_3.png' @ error/png.c/ReadPNGImage/3927. convert: no images defined `plot_3.png' @ error/convert.c/ConvertImageCommand/3210. correction on plasma position failed Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.36s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.68s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.79s plotting time 1.00s ===== plotting done ===== plotting time 0.94s real 0m6.434s user 0m5.120s sys 0m0.248s === postanalysis === Time: 6,435s correction on plasma position failed Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.05s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.52s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.77s plotting time 1.12s ===== plotting done ===== plotting time 0.78s real 0m6.295s user 0m5.284s sys 0m0.256s Thu Oct 12 20:02:05 CEST 2017 ============== action: clean ======================= make: *** No rule to make target 'clean'. Stop. make: Entering directory '/golem/database/operation/tasks/Training/2017/121017_1955/195934/analysis/Basics/0612AdvancedAnalysis.ON' make: *** No rule to make target 'clean'. Stop. make: Leaving directory '/golem/database/operation/tasks/Training/2017/121017_1955/195934/analysis/Basics/0612AdvancedAnalysis.ON' === plots === Time: 6,300s Thu Oct 12 20:02:25 CEST 2017 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Training/2017/121017_1955/195934/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis main.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... correction on plasma position failed Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24872/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.11s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.38s Some mistake during get_data: Missing file: /golem/database/operation/shots/24872/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.63s plotting time 0.62s ===== plotting done ===== plotting time 0.65s real 0m4.761s user 0m4.168s sys 0m0.208s === postanalysis === Time: 4,763s