Mon Nov 6 21:11:14 CET 2017 ============== action: acquisition ======================= real 0m0.001s user 0m0.000s sys 0m0.000s === acquisition done === Time: .0019s Mon Nov 6 21:11:14 CET 2017 ============== action: analysis ======================= Performing advanced discharge analysis I 0.00451466 B 0.322621 P 30.7352 n 0.118931 R 0.4 Aspect 0.25 confinent time = 0.903872145503 real 0m0.583s user 0m0.532s sys 0m0.044s === analysis done === Time: .5838s Mon Nov 6 21:11:14 CET 2017 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Training/2017/061117_1647/210827/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis Monmain.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan main.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... convert: Expected 8192 bytes; found 8090 bytes `plot_3.png' @ warning/png.c/MagickPNGWarningHandler/1669. convert: Read Exception `plot_3.png' @ error/png.c/MagickPNGErrorHandler/1643. convert: corrupt image `plot_3.png' @ error/png.c/ReadPNGImage/3973. convert: no images defined `plot_3.png' @ error/convert.c/ConvertImageCommand/3210. correction on plasma position failed Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.32s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.57s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.82s plotting time 0.85s ===== plotting done ===== plotting time 0.77s real 0m6.055s user 0m5.412s sys 0m0.324s === postanalysis === Time: 6,056s correction on plasma position failed Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.23s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.40s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.94s plotting time 0.81s ===== plotting done ===== plotting time 0.63s real 0m5.753s user 0m5.324s sys 0m0.316s Mon Nov 6 21:11:21 CET 2017 ============== action: clean ======================= make: *** No rule to make target 'clean'. Stop. make: Entering directory '/golem/database/operation/tasks/Training/2017/061117_1647/210827/analysis/Basics/0612AdvancedAnalysis.ON' make: *** No rule to make target 'clean'. Stop. make: Leaving directory '/golem/database/operation/tasks/Training/2017/061117_1647/210827/analysis/Basics/0612AdvancedAnalysis.ON' === plots === Time: 5,758s Mon Nov 6 21:11:30 CET 2017 !!! ============== action: postanalysis ======================= LOCAL_PATH /golem/database/operation/tasks/Training/2017/061117_1647/210827/analysis/Basics/0612AdvancedAnalysis.ON Performing advanced discharge postanalysis main.py:187: RuntimeWarning: invalid value encountered in greater safety_factor[safety_factor > 2* nanmedian(safety_factor[ind_plasma])] = nan /golem/database/pygolem_lite/modules.py:342: RuntimeWarning: invalid value encountered in divide if dy/amax(abs(array(yrange))) < 1e-6: # constant line ... correction on plasma position failed Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/plasma_radius !!!! electron_density correction failed !!! Missing file: /golem/database/operation/shots/24998/diagnostics/Magnetic/0612PlasmaPosition_TO.ON/results/R_position plotting time 1.08s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//temperature plotting time 0.41s Some mistake during get_data: Missing file: /golem/database/operation/shots/24998/analysis/Radiation/1212Impurities_TO.ON/data//TotalPower plotting time 0.55s plotting time 0.61s ===== plotting done ===== plotting time 0.64s real 0m4.604s user 0m4.092s sys 0m0.192s === postanalysis === Time: 4,606s