Tokamak GOLEM - Shot Database - 25449

[Template source]
[WebLog]
Date: 2017-12-13 - 14:42:04
Session: TrainingCourses/Universities/Uni_Padova/17
Comment: GUESTS - As before, with preion

    Basic parameters: (compare)

  • Gas pressure pch:0.59->4.02 mPa (request: 4 mPa) WIKI
  • Working gas: H
  • Preionization: Upper el. gun
  • Chamber temperature: 24.30 C
  • CBt capacitors charged to: 600 V, triggered 5.0 ms WIKI
  • CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors charged to: 500 V, triggered 6.0 ms WIKI
  • CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • Max saturation of iron core transformator: 95% WIKI
  • Level of noise (dBt) in room: 0.007 V
  • Probability of breakdown: 62% WIKI
  • Time since session beginning: 0:45:15 h