Tokamak GOLEM - Shot Database - 26057

[Template source]
[WebLog]
Date: 2018-02-01 - 07:26:33
Session: TrainingCourses/PlasmaSchools/ASPNF.th/18
Comment: TrainingCourses/PlasmaSchools/ASPNF.th/18/0118Group_6 - Group nb. 6

    Basic parameters: (compare)

  • Gas pressure pch:0.61->2.57 mPa (request: 4 mPa) WIKI
  • Working gas: H
  • Preionization: Upper el. gun
  • Chamber temperature: 25.00 C
  • CBt capacitors charged to: 600 V, triggered 5.0 ms WIKI
  • CBD capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • CCD capacitors charged to: 500 V, triggered 6.0 ms WIKI
  • CST capacitors charged to: 0 V, triggered 5.0 ms WIKI
  • Max saturation of iron core transformator: 95% WIKI
  • Level of noise (dBt) in room: 0.007 V
  • Probability of breakdown: 2% WIKI
  • Time since session beginning: 0:43:47 h
WIKI
WIKI
WIKI
WIKI

Data Acquisition Systems (DAS):


TektronixDPO

RigolDS

RigolDS

NIstandard

Papouch_Za

Papouch_St

Diagnostics:


Interferometer

Spectrometer

FastCamera

Analysis:


HistoricalAnalysis

ShotHomepage

AdvancedAnalysis

Impurities_TO

Students:

Guests:

Acknowledgement:


Thanks to the specific help and

Diagnostics

Analysis

DAS

Vacuum log

Other

Navigation