Test Bt a fake trigrovani s bypass kabelem .. testy
Basic parameters:
(
compare
)
Gas pressure p
ch
:
0.76
->
20.39
mPa (request: 20 mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
25.30
C
C
B
t
capacitors charged to:
1200 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
500 V
, triggered
5.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Level of noise
(dBt)
in room:
0.008 V
Probability of breakdown:
94%
WIKI
Time since session beginning: 0:27:34 h
Plasma parameters:
Plasma life time
8.2
[ms] (from
6.9
to
15.1
)
Mean toroidal magnetic field Bt:
0.24
T
WIKI
Mean plasma current:
1.54
kA
WIKI
Mean Uloop:
12.10
V
WIKI
Break down voltage:
11.5
V
WIKI
Ohmic heating power:
18.57
kW
Q edge:
6.9
WIKI
Electron temperature:
14.5
eV
WIKI
Line electron density:
N/A
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO3014
NIstandard
TektronixMSO58
Diagnostics:
Spectrometer
Analysis:
ShotHomepage
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✓
Spectrometer
Analysis
✓
ShotHomepage
DAS
✓
TektronixDPO
✓
NIstandard
✕
TektronixMSO
Vacuum log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 31MB
Navigation
current
next
|
previous
|