Spectrometer

[Template source] [Log]

Parameters:

  • Spectrometer: Ocean Optics Spectrometer
  • Serial Number: HR+C1886
  • Date and time (GMT): Thu Dec 13 18:48:50 2018
  • Number of spectra: 29
  • Resolution [px]: 2048
  • Integration time [ms]: 1.67
  • Acquisition time [ms]: 1.66
  • Board temperature [C]: 24.123
  • Time stamps [ms]: [ 1. 3.2952 4.2319 6.5395 7.4824 9.7793 10.8541 13.1586 14.2312 16.5297 17.6042 19.9066 20.8556 23.1571 24.2294 26.5305 27.6061 29.9049 30.8549 33.1586 34.2321 36.53 37.605 39.9079 40.9814 43.2817 44.231 46.532 47.6063]
  • Noise RMS [counts]: 10.0

Data [Source]

Measured spectra
# All identified spectral lines

Spectra

Spectra

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data (txt) spectra.txt_Data_.txt None Spectral resolved radiation

Accessible data: [data_configuration.cfg] [config.py] - (more details, all data)

Identifier

File name

Units

Description

spectrometr:data_calib (txt) spectrum_calibrated None Spectral resolved radiation, relativey calibrated