Navigation
current
next
|
previous
|
GOLEM
»
Shot #29831
»
Tokamak GOLEM - Shot Database - 29831
[Template source]
[WebLog]
Date:
2019-03-07 -
10:44:34
Session:
Training/2019
Comment:
Stabilization ĺog shrink again again again
Basic parameters:
(
compare
)
Gas pressure p
ch
:
0.55
->
9.78
mPa (request: 10 mPa)
WIKI
Working gas:
H
Preionization: Upper el. gun
Chamber temperature:
31.30
C
C
B
t
capacitors charged to:
1300 V
, triggered
5.0 ms
WIKI
C
BD
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
C
CD
capacitors charged to:
450 V
, triggered
5.0 ms
WIKI
C
ST
capacitors charged to:
0 V
, triggered
5.0 ms
WIKI
Level of noise
(dBt)
in room:
0.053 V
Probability of breakdown:
95%
WIKI
Time since session beginning: 3:34:44 h
Plasma parameters:
Plasma life time
20.7
[ms] (from
7.2
to
28.0
)
Mean toroidal magnetic field Bt:
0.40
T
WIKI
Mean plasma current:
3.80
kA
WIKI
Mean Uloop:
5.33
V
WIKI
Break down voltage:
10.4
V
WIKI
Ohmic heating power:
20.28
kW
Q edge:
4.7
WIKI
Electron temperature:
45.7
eV
WIKI
Line electron density:
5.35
[10^17.m^-2]
WIKI
WIKI
WIKI
WIKI
WIKI
WIKI
basicdiagn processing evolution:
raw
→
integrated
→
final
Basic diagnostics:
loop_voltage
,
plasma_current
,
toroidal_field
,
photodiode
,
hxr
,
other diagnostics
Data Acquisition Systems (DAS):
TektronixDPO3014
Papouch_Ja
NIstandard
NIturbo_RT
Papouch_Za
TektronixMSO58
Papouch_St
Papouch_Ko
NIoctopus
Diagnostics:
Interferometer
Spectrometer
Bolometers_BL
FastCamera
Analysis:
HistoricalAnalysis
ShotHomepage
AdvancedAnalysis
Impurities_TO
Students:
Guests:
Acknowledgement:
Thanks to the specific help
and
Diagnostics
✓
Interferometer
✓
Spectrometer
✕
Bolometers_BL
✓
FastCamera
Analysis
✓
HistoricalAnalysis
✓
ShotHomepage
✓
AdvancedAnalysis
✓
Impurities_TO
DAS
✓
TektronixDPO
✓
Papouch_Ja
✓
NIstandard
✕
NIturbo_RT
✓
Papouch_Za
✕
TektronixMSO
✓
Papouch_St
✓
Papouch_Ko
✓
NIoctopus
Vacuum log
Other
Data
References
About
Wiki
Utilities
Navigation
Next
Previous
Current
Go to shot
[Main template]
Disk usage: 78MB
Navigation
current
next
|
previous
|