\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem No: 33986 - the only fully opensource tokamak

Tokamak GOLEM - Shot Database - 33986

[Web log]
The date of discharge execution20-10-27 11:02:12 [Shot logbook]
The session missionSandBox --> SW development
The session ID33984
The discharge commentPlasma discharge
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 1000 --Ucd 450 --Tcd 2000 --preionization 1 --gas H --pressure 10 --Bt_orientation CW --CD_orientation CW --vacuum_shot 33980 --comment "Plasma discharge"

    Technological parameters:

    Plasma parameters:

  • Discharge duration: \(\tau\sub{p}\)=6.45 ms
  • Loop voltage:\(\overline{U\sub{loop}}\)\(\)=9.39 V; \(\maximum{{\tau \in [discharge]}U\sub{loop}}\)=17.47 V
  • Toroidal magnetic field: \(\overline{B\sub{t}}\)=0.17 T; \(\max_{\tau \in [discharge]}B\sub{t}\)=0.24 T
  • Plasma current: \(\overline{I\sub{p}}\)=1.44 kA; \(\max_{\tau \in [discharge]}I\sub{p}\)=1.83 kA

Basic diagnostics

Data Acquisition Systems (DAS)

HXRdiagnostics

data dir
PetiProbe

data dir
PlasmaPosition

data dir
StandardDAS

data dir

Diagnostics Systems

BasicDiagnostics

data dir
FastExCameras

data dir
HXRprobes

data dir
LimiterMirnovCoils

data dir
PetiProbe

data dir

Analysis

0. wave:

BasicDiagnostics

data dir
Homepage

data dir
1. wave:

InnerStabilization

data dir
2. wave:

Infrastructure

Chamber

data dir
Charger

data dir
Discharge

data dir
Operator

data dir

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @

Diagnostics

Analysis

DASs

Vacuum log

Other

Navigation