16:55:01 #35345 /VacuumLog: Chamber: 0.90 mPa, 43.40 C, ForVacuum: 0.825 Pa, Gas: NULL, GasValve: 0.00 V 16:55:02 #35346 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Fast Ion temperature measurement with electrostatic probes 16:55:02 #35346 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:55:03 #35346 /GetReadyTheDischarge: Going with gas pressure 10 16:55:03 #35346 /GetReadyTheDischarge: Going with gas type H 16:55:03 #35346 /GetReadyTheDischarge: Discharge with Hydrogen request 16:55:03 #35346 /GetReadyTheDischarge: Discharge with 10 mPa request with GetReadyTheDischarge 16:55:03 #35346 /GetReadyTheDischarge: Diving into .. 16:55:03 #35346 /GetReadyTheDischarge: Going with Bt_orientation CW 16:55:03 #35346 /GetReadyTheDischarge: Discharge with Bt CW request 16:55:03 #35346 /GetReadyTheDischarge: Going with CD_orientation CW 16:55:03 #35346 /GetReadyTheDischarge: Discharge with CD CW request 16:55:05 #35346 /VacuumLog: Chamber: 0.90 mPa, 43.40 C, ForVacuum: 0.825 Pa, Gas: H2, GasValve: 21.14 V 16:55:08 #35346 /VacuumLog: Chamber: 1.69 mPa, 43.40 C, ForVacuum: 0.88 Pa, Gas: H2, GasValve: 22.93 V 16:55:10 #35346 /GetReadyTheDischarge: Bt capacitor charging started 16:55:12 #35346 /VacuumLog: Chamber: 6.05 mPa, 43.40 C, ForVacuum: 1.6 Pa, Gas: H2, GasValve: 24.71 V 16:55:15 #35346 /GetReadyTheDischarge: Cd capacitor charging started 16:55:15 #35346 /ChargingResistorsAllOFF: Diving into .. 16:55:15 #35346 /GetReadyTheDischarge: U_Bt: 1200, Hrana: 98 16:55:15 #35346 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 16:55:15 #35346 /GetReadyTheDischarge: Charging ... HV=-6 V 16:55:16 #35346 /GetReadyTheDischarge: Charging ... HV=23 V a, Gas: H2, GasValve: 24.28 V 16:55:16 #35346 /GetReadyTheDischarge: Charging ... HV=-6 V 16:55:17 #35346 /GetReadyTheDischarge: Charging ... HV=28 V 16:55:17 #35346 /GetReadyTheDischarge: Charging ... HV=28 V 16:55:17 #35346 /GetReadyTheDischarge: Charging ... HV=90 V 16:55:18 #35346 /GetReadyTheDischarge: Charging ... HV=90 V 16:55:18 #35346 /GetReadyTheDischarge: Charging ... HV=90 V 16:55:19 #35346 /GetReadyTheDischarge: Charging ... HV=151 V 16:55:19 #35346 /GetReadyTheDischarge: Charging ... HV=151 V 16:55:20 #35346 /GetReadyTheDischarge: Charging ... HV=210 V 16:55:20 #35346 /GetReadyTheDischarge: Charging ... HV=210 V 16:55:21 #35346 /GetReadyTheDischarge: Charging ... HV=267 V 16:55:21 #35346 /GetReadyTheDischarge: Charging ... HV=267 V 16:55:21 #35346 /GetReadyTheDischarge: Charging ... HV=267 V 16:55:22 #35346 /GetReadyTheDischarge: Charging ... HV=322 V 16:55:22 #35346 /GetReadyTheDischarge: Charging ... HV=322 V 16:55:22 #35346 /VacuumLog: Chamber: 10.20 mPa, 43.30 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 24.06 V 16:55:23 #35346 /GetReadyTheDischarge: Charging ... HV=372 V 16:55:23 #35346 /GetReadyTheDischarge: Charging ... HV=372 V 16:55:24 #35346 /GetReadyTheDischarge: Charging ... HV=23 V 16:55:24 #35346 /GetReadyTheDischarge: Charging ... HV=420 V 16:55:24 #35346 /GetReadyTheDischarge: Cd capacitor charging finished @ 420 V 16:55:25 #35346 /GetReadyTheDischarge: Charging ... HV=420 V 16:55:25 #35346 /GetReadyTheDischarge: Charging ... HV=469 V 16:55:25 #35346 /GetReadyTheDischarge: Charging ... HV=469 V 16:55:26 #35346 /GetReadyTheDischarge: Charging ... HV=469 V 16:55:26 #35346 /GetReadyTheDischarge: Charging ... HV=520 V Gas: H2, GasValve: 24.06 V 16:55:27 #35346 /GetReadyTheDischarge: Charging ... HV=520 V 16:55:27 #35346 /GetReadyTheDischarge: Charging ... HV=23 V 16:55:28 #35346 /GetReadyTheDischarge: Charging ... HV=571 V 16:55:28 #35346 /GetReadyTheDischarge: Charging ... HV=571 V 16:55:28 #35346 /GetReadyTheDischarge: Charging ... HV=617 V 16:55:29 #35346 /GetReadyTheDischarge: Charging ... HV=617 V 16:55:29 #35346 /GetReadyTheDischarge: Charging ... HV=661 V 16:55:30 #35346 /GetReadyTheDischarge: Charging ... HV=661 V 16:55:30 #35346 /GetReadyTheDischarge: Charging ... HV=661 V 16:55:31 #35346 /GetReadyTheDischarge: Charging ... HV=706 V 16:55:31 #35346 /GetReadyTheDischarge: Charging ... HV=706 V 16:55:31 #35346 /GetReadyTheDischarge: Charging ... HV=746 V 16:55:32 #35346 /GetReadyTheDischarge: Charging ... HV=746 V 16:55:32 #35346 /GetReadyTheDischarge: Charging ... HV=746 V 16:55:33 #35346 /GetReadyTheDischarge: Charging ... HV=783 V 16:55:33 #35346 /VacuumLog: Chamber: 10.10 mPa, 43.30 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.06 V 16:55:33 #35346 /GetReadyTheDischarge: Charging ... HV=783 V 16:55:34 #35346 /GetReadyTheDischarge: Charging ... HV=819 V 16:55:34 #35346 /GetReadyTheDischarge: Charging ... HV=819 V 16:55:34 #35346 /GetReadyTheDischarge: Charging ... HV=819 V 16:55:35 #35346 /GetReadyTheDischarge: Charging ... HV=853 V 16:55:35 #35346 /GetReadyTheDischarge: Charging ... HV=853 V 16:55:36 #35346 /GetReadyTheDischarge: Charging ... HV=888 V 16:55:36 #35346 /GetReadyTheDischarge: Charging ... HV=888 V 16:55:37 #35346 /GetReadyTheDischarge: Charging ... HV=888 V 16:55:37 #35346 /VacuumLog: Chamber: 10.10 mPa, 43.30 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.06 V 16:55:37 #35346 /GetReadyTheDischarge: Charging ... HV=919 V 16:55:37 #35346 /GetReadyTheDischarge: Charging ... HV=919 V 16:55:38 #35346 /GetReadyTheDischarge: Charging ... HV=951 V 16:55:38 #35346 /GetReadyTheDischarge: Charging ... HV=951 V 16:55:39 #35346 /GetReadyTheDischarge: Charging ... HV=951 V 16:55:39 #35346 /GetReadyTheDischarge: Charging ... HV=979 V 16:55:39 #35346 /GetReadyTheDischarge: Charging ... HV=979 V 16:55:40 #35346 /GetReadyTheDischarge: Charging ... HV=1005 V 16:55:40 #35346 /GetReadyTheDischarge: Charging ... HV=1005 V Gas: H2, GasValve: 24.06 V 16:55:41 #35346 /GetReadyTheDischarge: Charging ... HV=1005 V 16:55:41 #35346 /GetReadyTheDischarge: Charging ... HV=1032 V 16:55:42 #35346 /GetReadyTheDischarge: Charging ... HV=1032 V 16:55:42 #35346 /GetReadyTheDischarge: Charging ... HV=1060 V 16:55:42 #35346 /GetReadyTheDischarge: Charging ... HV=1060 V 16:55:43 #35346 /GetReadyTheDischarge: Charging ... HV=1060 V 16:55:43 #35346 /GetReadyTheDischarge: Charging ... HV=1084 V 16:55:44 #35346 /GetReadyTheDischarge: Charging ... HV=1084 V 16:55:44 #35346 /GetReadyTheDischarge: Charging ... HV=1107 V 16:55:45 #35346 /GetReadyTheDischarge: Charging ... HV=1107 V 16:55:45 #35346 /GetReadyTheDischarge: Charging ... HV=1107 V 16:55:45 #35346 /GetReadyTheDischarge: Charging ... HV=1128 V 16:55:46 #35346 /GetReadyTheDischarge: Charging ... HV=1128 V 16:55:46 #35346 /GetReadyTheDischarge: Charging ... HV=1128 V 16:55:47 #35346 /GetReadyTheDischarge: Charging ... HV=1149 V 16:55:47 #35346 /GetReadyTheDischarge: Charging ... HV=1149 V 16:55:48 #35346 /GetReadyTheDischarge: Charging ... HV=1170 V 16:55:48 #35346 /GetReadyTheDischarge: Charging ... HV=1170 V 16:55:48 #35346 /GetReadyTheDischarge: Charging ... HV=1170 V 16:55:49 #35346 /GetReadyTheDischarge: Charging ... HV=1190 V 16:55:49 #35346 /GetReadyTheDischarge: Bt slow PowSup 16:55:49 #35346 /ChargingResistorsAllON: Diving into .. 16:55:49 #35346 /GetReadyTheDischarge: Charging ... HV=1190 V 16:55:50 #35346 /GetReadyTheDischarge: Charging ... HV=1209 V 16:55:50 #35346 /ChargingResistorsAllON: Diving into .. 16:55:51 #35346 /GetReadyTheDischarge: Bt capacitor charging finished @ 1209 V 16:55:51 #35346 /ChargingResistorsAllON: Diving into .. 16:55:51 #35346 /GetReadyTheDischarge: Ascending from .. 16:55:51 #35346 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:55:51 #35346 TektrMSO64-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:55:51 #35346 RigolDG1032Z-a.golem/LogTheDeviceAction: The FG4ElstatProbes action on stage with Arming 16:55:51 #35346 TektrMSO58-a/LogTheDeviceAction: The 21_PetiProbe_JAetal action on stage with Arming 16:55:54 #35346 /VacuumLog: Chamber: 10.10 mPa, 43.20 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 24.06 V 16:55:55 #35346 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:55:58 #35346 /VacuumLog: Chamber: 10.10 mPa, 43.20 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 24.06 V 16:56:02 #35346 /VacuumLog: Chamber: 10.20 mPa, 43.20 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 24.06 V 16:56:05 #35346 /VacuumLog: Chamber: 10.20 mPa, 43.10 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 24.06 V 16:56:05 #35346 /Trigger: Going through .. 16:56:05 #35346 Discharge/HWTrigger: Going through .. 16:56:05 #35346 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 16:56:05 #35346 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:56:06 #35346 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 16:56:08 #35346 /ChargingResistorsAllON: Diving into .. 16:56:09 #35346 /VacuumLog: Chamber: 7.80 mPa, 43.20 C, ForVacuum: 3.6 Pa, Gas: H2, GasValve: 0.00 V 16:56:11 #35346 /SecurePostDischargeState: Going through .. 16:56:11 #35346 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:56:12 #35346 /VacuumLog: Chamber: 1.23 mPa, 43.20 C, ForVacuum: 1.9 Pa, Gas: NULL, GasValve: 0.00 V 16:56:16 #35346 /VacuumLog: Chamber: 1.12 mPa, 43.20 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 16:56:19 #35346 /VacuumLog: Chamber: 1.08 mPa, 43.20 C, ForVacuum: 0.825 Pa, Gas: NULL, GasValve: 0.00 V 16:56:23 #35346 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:56:23 #35346 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:56:23 #35346 /VacuumLog: Chamber: 1.05 mPa, 43.30 C, ForVacuum: 0.81 Pa, Gas: NULL, GasValve: 0.00 V 16:56:23 #35346 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:56:24 #35346 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:56:24 #35346 /OperatorFunction: General Calling PublishOnStageTasks 16:56:26 #35346 /VacuumLog: Chamber: 1.03 mPa, 43.20 C, ForVacuum: 0.81 Pa, Gas: NULL, GasValve: 0.00 V 16:56:27 #35346 /DoShotHomepage: Ascending from .. 16:56:29 #35346 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:56:29 #35346 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:56:30 #35346 /VacuumLog: Chamber: 1.01 mPa, 43.10 C, ForVacuum: 0.81 Pa, Gas: NULL, GasValve: 0.00 V 16:56:33 #35346 /VacuumLog: Chamber: 0.99 mPa, 43.10 C, ForVacuum: 0.815 Pa, Gas: NULL, GasValve: 0.00 V 16:56:37 #35346 /VacuumLog: Chamber: 0.98 mPa, 43.10 C, ForVacuum: 0.815 Pa, Gas: NULL, GasValve: 0.00 V 16:56:40 #35346 /VacuumLog: Chamber: 0.97 mPa, 43.10 C, ForVacuum: 0.815 Pa, Gas: NULL, GasValve: 0.00 V 16:56:43 #35346 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OTHERS_WAVE end 16:56:43 #35346 /OperatorFunction: General Calling PublishFinally 16:56:44 #35346 /VacuumLog: Chamber: 0.96 mPa, 43.10 C, ForVacuum: 0.815 Pa, Gas: NULL, GasValve: 0.00 V 16:56:46 #35346 /DoShotHomepage: Ascending from ..