Golem shot: 3576

2010-09-16 - 143024

Basic parameters:
  • Chamber pressure pchamber : 1.68->22.83 mPa (request: 20 mp)
  • Chamber temperature: 1 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 585 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.95 over 7.05 to 15.00 [ms]
  • Mean toroidal magnetic field Bt: 0.390 T
  • Mean plasma current: 3.8 kA
  • Mean Uloop: 10.6 V
  • Break down voltage: 14.2 V
  • Plasma total charge: 26.7 C
  • Ohmic heating power: 40.3 kW
  • Q edge: 9.3
  • Central electron temperature: 32.0 eV

Thanks to the specific help and