Golem shot: 3579

2010-09-16 - 155734

Basic parameters:
  • Chamber pressure pchamber : 1.58->20.66 mPa (request: 20 mp)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 800 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 2,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 245 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 7.99 over 7.01 to 15.00 [ms]
  • Mean toroidal magnetic field Bt: 0.381 T
  • Mean plasma current: 3.5 kA
  • Mean Uloop: 10.2 V
  • Break down voltage: 14.0 V
  • Plasma total charge: 24.4 C
  • Ohmic heating power: 35.7 kW
  • Q edge: 9.8
  • Central electron temperature: 30.0 eV

Thanks to the specific help and