17:08:38 #35861 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Edge Plasma physics studies via electrostatic probes 17:08:38 #35861 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:08:38 #35861 /GetReadyTheDischarge: Going with gas pressure 16 17:08:38 #35861 /GetReadyTheDischarge: Going with gas type H 17:08:38 17:08:38 #35861 /GetReadyTheDischarge: Discharge with Hydrogen request 17:08:38 #35861 /GetReadyTheDischarge: Discharge with 16 mPa request 17:08:39 #35817:08:39 #35861 /VacuumLog: Chamber: 0.28 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: H2, GasValve: 0.00 V e with CD CW request 17:08:42 #35861 /VacuumLog: Chamber: 2.51 mPa, 36.80 C, ForVacuum: 0.565 Pa, Gas: H2, GasValve: 25.29 V 17:08:46 #35861 /GetReadyTheDischarge: Bt capacitor charging started 17:08:46 #35861 /VacuumLog: Chamber: 33.10 mPa, 36.80 C, ForVacuum: 3.4 Pa, Gas: H2, GasValve: 25.27 V 17:08:50 #35861 /VacuumLog: Chamber: 13.90 mPa, 36.80 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 23.16 V 17:08:50 #35861 /GetReadyTheDischarge: Cd capacitor charging started 17:08:50 #35861 /ChargingResistorsAllOFF: Diving into .. 17:08:50 #35861 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 17:08:50 #35861 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 17:08:51 #35861 /GetReadyTheDischarge: Charging ... HV=-8 V 17:08:51 #35861 /GetReadyTheDischarge: Charging ... HV=-2 V 17:08:51 #35861 /GetReadyTheDischarge: Charging ... HV=-2 V 17:08:52 #35861 /GetReadyTheDischarge: Charging ... HV=-2 V 17:08:52 #35861 /GetReadyTheDischarge: Charging ... HV=46 V 17:08:53 #35861 /GetReadyTheDischarge: Charging ... HV=46 V 17:08:53 #35861 /GetReadyTheDischarge: Charging ... HV=109 V 17:08:54 #35861 /GetReadyTheDischarge: Charging ... HV=109 V 17:08:54 #35861 /GetReadyTheDischarge: Charging ... HV=0 V 17:08:54 #35861 /GetReadyTheDischarge: Charging ... HV=170 V 17:08:55 #35861 /GetReadyTheDischarge: Charging ... HV=170 V 17:08:55 #35861 /GetReadyTheDischarge: Charging ... HV=229 V 17:08:56 #35861 /GetReadyTheDischarge: Charging ... HV=229 V 17:08:56 #35861 /GetReadyTheDischarge: Charging ... HV=286 V 17:08:57 #35861 /VacuumLog: Chamber: 15.70 mPa, 36.70 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 23.42 V 17:08:57 #35861 /GetReadyTheDischarge: Charging ... HV=286 V 17:08:57 #35861 /GetReadyTheDischarge: Charging ... HV=286 V 17:08:57 #35861 /GetReadyTheDischarge: Charging ... HV=341 V 17:08:58 #35861 /GetReadyTheDischarge: Charging ... HV=341 V 17:08:58 #35861 /GetReadyTheDischarge: Charging ... HV=391 V 17:08:59 #35861 /GetReadyTheDischarge: Charging ... HV=391 V 17:08:59 #35861 /GetReadyTheDischarge: Charging ... HV=391 V 17:09:00 #35861 /GetReadyTheDischarge: Charging ... HV=440 V 17:09:00 #35861 /GetReadyTheDischarge: Charging ... HV=440 V 17:09:00 #35861 /VacuumLog: Chamber: 15.50 mPa, 36.80 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 23.42 V 17:09:01 #35861 /GetReadyTheDischarge: Charging ... HV=487 V 17:09:01 #35861 /GetReadyTheDischarge: Cd capacitor charging finished @ 487 V 17:09:01 #35861 /GetReadyTheDischarge: Charging ... HV=487 V 17:09:01 #35861 /GetReadyTheDischarge: Charging ... HV=487 V 17:09:02 #35861 /GetReadyTheDischarge: Charging ... HV=533 V 17:09:02 #35861 /GetReadyTheDischarge: Charging ... HV=533 V 17:09:03 #35861 /GetReadyTheDischarge: Charging ... HV=583 V 17:09:03 #35861 /GetReadyTheDischarge: Charging ... HV=583 V 17:09:04 #35861 /GetReadyTheDischarge: Charging ... HV=583 V 17:09:04 #35861 /GetReadyTheDischarge: Charging ... HV=628 V , Gas: H2, GasValve: 23.42 V 17:09:04 #35861 /GetReadyTheDischarge: Charging ... HV=628 V 17:09:05 #35861 /GetReadyTheDischarge: Charging ... HV=675 V 17:09:05 #35861 /GetReadyTheDischarge: Charging ... HV=675 V 17:09:06 #35861 /GetReadyTheDischarge: Charging ... HV=675 V 17:09:06 #35861 /GetReadyTheDischarge: Charging ... HV=718 V 17:09:07 #35861 /GetReadyTheDischarge: Charging ... HV=0 V 17:09:07 #35861 /GetReadyTheDischarge: Charging ... HV=758 V 17:09:07 #35861 /GetReadyTheDischarge: Charging ... HV=758 V 17:09:08 #35861 /GetReadyTheDischarge: Charging ... HV=758 V 17:09:08 #35861 /GetReadyTheDischarge: Charging ... HV=796 V 17:09:08 #35861 /GetReadyTheDischarge: Bt slow PowSup 17:09:08 #35861 /ChargingResistorsAllON: Diving into .. 17:09:09 #35861 /GetReadyTheDischarge: Charging ... HV=796 V 17:09:09 #35861 /GetReadyTheDischarge: Charging ... HV=832 V 17:09:10 #35861 /ChargingResistorsAllON: Diving into .. 17:09:10 #35861 /GetReadyTheDischarge: Bt capacitor charging finished @ 832 V 17:09:10 #35861 /ChargingResistorsAllON: Diving into .. 17:09:11 #35861 /GetReadyTheDischarge: Ascending from .. 17:09:11 #35861 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:09:11 #35861 TektrMSO64-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:09:11 #35861 RigolDG1032Z-a.golem/LogTheDeviceAction: The FG4ElstatProbes action on stage with Arming 17:09:11 #35861 TektrMSO64-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:09:11 #35861 TektrMSO58-a/LogTheDeviceAction: The 21_PetiProbe_KHetal action on stage with Arming 17:09:11 #35861 /VacuumLog: Chamber: 15.20 mPa, 36.70 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 23.42 V 17:09:14 #35861 /VacuumLog: Chamber: 15.20 mPa, 36.70 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 23.42 V 17:09:15 #35861 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:09:18 #35861 /VacuumLog: Chamber: 15.20 mPa, 36.70 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 23.42 V 17:09:21 #35861 /VacuumLog: Chamber: 15.20 mPa, 36.70 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 23.42 V 17:09:25 #35861 /Trigger: Going through .. 17:09:25 #35861 Discharge/HWTrigger: Going through .. 17:09:25 #35861 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 17:09:25 #35861 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:09:25 #35861 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 17:09:28 #35861 /ChargingResistorsAllON: Diving into .. 17:09:29 #35861 /VacuumLog: Chamber: 13.40 mPa, 36.70 C, ForVacuum: 4.25 Pa, Gas: NULL, GasValve: 0.00 V 17:09:30 #35861 /SecurePostDischargeState: Going through .. 17:09:30 #35861 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:09:32 #35861 /VacuumLog: Chamber: 0.58 mPa, 36.70 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 17:09:33 #35861 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:09:33 #35861 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 17:09:33 #35861 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 17:09:34 #35861 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 17:09:34 #35861 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 17:09:36 #35861 /VacuumLog: Chamber: 0.49 mPa, 36.70 C, ForVacuum: 0.545 Pa, Gas: NULL, GasValve: 0.00 V 17:09:39 #35861 /VacuumLog: Chamber: 0.45 mPa, 36.80 C, ForVacuum: 0.405 Pa, Gas: NULL, GasValve: 0.00 V 17:09:43 #35861 /VacuumLog: Chamber: 0.43 mPa, 36.80 C, ForVacuum: 0.395 Pa, Gas: NULL, GasValve: 0.00 V 17:09:47 #35861 /VacuumLog: Chamber: 0.41 mPa, 36.80 C, ForVacuum: 0.405 Pa, Gas: NULL, GasValve: 0.00 V 17:09:50 #35861 /VacuumLog: Chamber: 0.39 mPa, 36.80 C, ForVacuum: 0.41 Pa, Gas: NULL, GasValve: 0.00 V 17:09:54 #35861 /VacuumLog: Chamber: 0.38 mPa, 36.80 C, ForVacuum: 0.415 Pa, Gas: NULL, GasValve: 0.00 V 17:09:54 #35861 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 17:09:54 #35861 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 17:09:57 #35861 /VacuumLog: Chamber: 0.37 mPa, 36.80 C, ForVacuum: 0.42 Pa, Gas: NULL, GasValve: 0.00 V 17:10:01 #35861 /VacuumLog: Chamber: 0.36 mPa, 36.80 C, ForVacuum: 0.42 Pa, Gas: NULL, GasValve: 0.00 V 17:10:01 #35861 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:10:01 #35861 /DischargeFunction: General Calling PublishOnStageTasks 17:10:04 #35861 /VacuumLog: Chamber: 0.35 mPa, 36.80 C, ForVacuum: 0.42 Pa, Gas: NULL, GasValve: 0.00 V 17:10:07 #35861 /DoShotHomepage: Ascending from .. 17:10:08 #35861 /VacuumLog: Chamber: 0.35 mPa, 36.80 C, ForVacuum: 0.42 Pa, Gas: NULL, GasValve: 0.00 V 17:10:09 #35861 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 17:10:09 #35861 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 17:10:11 #35861 /VacuumLog: Chamber: 0.34 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:15 #35861 /VacuumLog: Chamber: 0.34 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:19 #35861 /VacuumLog: Chamber: 0.33 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:22 #35861 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OTHERS_WAVE end 17:10:22 #35861 /VacuumLog: Chamber: 0.33 mPa, 36.70 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:26 #35861 /VacuumLog: Chamber: 0.32 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:28 #35861 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ANALYSIS end 17:10:28 #35861 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@INFRASTRUCTURE end 17:10:28 #35861 /DischargeFunction: General Calling PublishFinally 17:10:29 #35861 /VacuumLog: Chamber: 0.32 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:33 #35861 /VacuumLog: Chamber: 0.32 mPa, 36.80 C, ForVacuum: 0.425 Pa, Gas: NULL, GasValve: 0.00 V 17:10:33 #35861 /DoShotHomepage: Ascending from ..