16:49:30 #36369 Discharge/PrepareDischargeEnv@SHM: Command Line Request: EDU 16:49:31 #36369 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 16:49:31 #36369 /GetReadyTheDischarge: Going with gas pressure 16 16:49:31 #36369 /GetReadyTheDischarge: Going with gas type H 16:49:31 #36369 /GetReadyTheDischarge: Discharge with Hydrogen request 16:49:31 #36369 /GetReadyTheDischarge: Discharge with 16 mPa request with GetReadyTheDischarge 16:49:31 #36369 /GetReadyTheDischarge: Diving into .. 16:49:31 #36369 /GetReadyTheDischarge: Going with Bt_orientation CW 16:49:31 #36369 /GetReadyTheDischarge: Discharge with Bt CW request 16:49:31 #36369 /GetReadyTheDischarge: Going with CD_orientation CW 16:49:31 #36369 /GetReadyTheDischarge: Discharge with CD CW request 16:49:33 #36369 /VacuumLog: Chamber: 2.16 mPa, 39.70 C, ForVacuum: 0.505 Pa, Gas: H2, GasValve: 23.52 V 16:49:37 #36369 /VacuumLog: Chamber: 27.50 mPa, 39.60 C, ForVacuum: 2.35 Pa, Gas: H2, GasValve: 20.62 V 16:49:38 #36369 /GetReadyTheDischarge: Bt capacitor charging started 16:49:40 #36369 /VacuumLog: Chamber: 13.10 mPa, 39.70 C, ForVacuum: 2.95 Pa, Gas: H2, GasValve: 21.22 V 16:49:43 #36369 /GetReadyTheDischarge: Cd capacitor charging started 16:49:43 #36369 /ChargingResistorsAllOFF: Diving into .. 16:49:43 #36369 /GetReadyTheDischarge: U_Bt: 450, Hrana: 98 16:49:43 #36369 /GetReadyTheDischarge: U_Et: 650, Hrana: 98 16:49:43 #36369 /GetReadyTheDischarge: Charging ... HV=-17 V 16:49:44 #36369 /GetReadyTheDischarge: Charging ... HV=-17 V 16:49:44 #36369 /VacuumLog: Chamber: 17.10 mPa, 39.70 C, ForVacuum: 2.95 Pa, Gas: H2, GasValve: 21.24 V 16:49:44 #36369 /GetReadyTheDischarge: Charging ... HV=-10 V 16:49:45 #36369 /GetReadyTheDischarge: Charging ... HV=-10 V 16:49:45 #36369 /GetReadyTheDischarge: Charging ... HV=22 V 16:49:45 #36369 /GetReadyTheDischarge: Charging ... HV=22 V 16:49:46 #36369 /GetReadyTheDischarge: Charging ... HV=22 V 16:49:46 #36369 /GetReadyTheDischarge: Charging ... HV=57 V 16:49:47 #36369 /GetReadyTheDischarge: Charging ... HV=57 V 16:49:47 #36369 /GetReadyTheDischarge: Charging ... HV=93 V 16:49:48 #36369 /GetReadyTheDischarge: Charging ... HV=93 V a, Gas: H2, GasValve: 21.28 V 16:49:48 #36369 /GetReadyTheDischarge: Charging ... HV=125 V 16:49:48 #36369 /GetReadyTheDischarge: Charging ... HV=125 V 16:49:49 #36369 /GetReadyTheDischarge: Charging ... HV=125 V 16:49:49 #36369 /GetReadyTheDischarge: Charging ... HV=159 V 16:49:50 #36369 /GetReadyTheDischarge: Charging ... HV=159 V 16:49:50 #36369 /GetReadyTheDischarge: Charging ... HV=191 V 16:49:51 #36369 /GetReadyTheDischarge: Charging ... HV=191 V 16:49:51 #36369 /GetReadyTheDischarge: Charging ... HV=191 V 16:49:52 #36369 /GetReadyTheDischarge: Charging ... HV=225 V 16:49:52 #36369 /GetReadyTheDischarge: Charging ... HV=225 V 16:49:52 #36369 /GetReadyTheDischarge: Charging ... HV=257 V 16:49:53 #36369 /GetReadyTheDischarge: Charging ... HV=257 V 16:49:53 #36369 /GetReadyTheDischarge: Charging ... HV=257 V 16:49:54 #36369 /GetReadyTheDischarge: Charging ... HV=286 V 16:49:54 #36369 /GetReadyTheDischarge: Charging ... HV=286 V 16:49:55 #36369 /GetReadyTheDischarge: Charging ... HV=318 V 16:49:55 #36369 /GetReadyTheDischarge: Charging ... HV=318 V 16:49:56 #36369 /GetReadyTheDischarge: Charging ... HV=318 V 16:49:56 #36369 /GetReadyTheDischarge: Charging ... HV=346 V 16:49:56 #36369 /GetReadyTheDischarge: Charging ... HV=346 V 16:49:57 #36369 /GetReadyTheDischarge: Charging ... HV=374 V 16:49:57 #36369 /GetReadyTheDischarge: Charging ... HV=374 V 16:49:58 #36369 /GetReadyTheDischarge: Charging ... HV=374 V 16:49:58 #36369 /GetReadyTheDischarge: Charging ... HV=400 V Gas: H2, GasValve: 21.28 V 16:49:59 #36369 /GetReadyTheDischarge: Charging ... HV=400 V 16:49:59 #36369 /GetReadyTheDischarge: Charging ... HV=427 V 16:49:59 #36369 /GetReadyTheDischarge: Charging ... HV=427 V 16:50:00 #36369 /GetReadyTheDischarge: Charging ... HV=454 V 16:50:00 #36369 /GetReadyTheDischarge: Bt capacitor charging finished @ 454 V 16:50:00 #36369 /GetReadyTheDischarge: Charging ... HV=454 V 16:50:01 #36369 /GetReadyTheDischarge: Charging ... HV=454 V 16:50:01 #36369 /GetReadyTheDischarge: Charging ... HV=533 V 16:50:02 #36369 /GetReadyTheDischarge: Charging ... HV=533 V 16:50:02 #36369 /GetReadyTheDischarge: Charging ... HV=750 V , Gas: H2, GasValve: 21.28 V 16:50:02 #36369 /ChargingResistorsAllON: Diving into .. 16:50:03 #36369 /GetReadyTheDischarge: Cd capacitor charging finished @ 750 V 16:50:03 #36369 /ChargingResistorsAllON: Diving into .. 16:50:03 #36369 /GetReadyTheDischarge: Ascending from .. 16:50:03 #36369 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 16:50:03 #36369 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:50:03 #36369 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 16:50:03 #36369 TektrMSO64-a/LogTheDeviceAction: The 21_PetiProbe_KHetal action on stage with Arming 16:50:03 #36369 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 16:50:05 #36369 /VacuumLog: Chamber: 14.60 mPa, 39.60 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 21.28 V 16:50:05 #36369 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 16:50:09 #36369 /VacuumLog: Chamber: 14.50 mPa, 39.60 C, ForVacuum: 2.7 Pa, Gas: H2, GasValve: 21.28 V 16:50:12 #36369 /VacuumLog: Chamber: 14.40 mPa, 39.60 C, ForVacuum: 2.7 Pa, Gas: H2, GasValve: 21.28 V 16:50:15 #36369 /Trigger: Going through .. 16:50:15 #36369 Discharge/HWTrigger: Going through .. 16:50:16 #36369 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 16:50:16 #36369 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 16:50:16 #36369 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 16:50:16 #36369 /VacuumLog: Chamber: 14.40 mPa, 39.60 C, ForVacuum: 2.7 Pa, Gas: H2, GasValve: 21.28 V 16:50:18 #36369 /ChargingResistorsAllON: Diving into .. 16:50:19 #36369 /VacuumLog: Chamber: 13.70 mPa, 39.60 C, ForVacuum: 2.7 Pa, Gas: NULL, GasValve: 0.00 V 16:50:21 #36369 /SecurePostDischargeState: Going through .. 16:50:21 #36369 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 16:50:23 #36369 /VacuumLog: Chamber: 0.90 mPa, 39.70 C, ForVacuum: 1.25 Pa, Gas: NULL, GasValve: 0.00 V 16:50:24 #36369 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 16:50:24 #36369 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 16:50:24 #36369 Papouch-Za/LOC_RawDataAcquiring: Papouch-Za: Start of acquiring 16:50:27 #36369 /VacuumLog: Chamber: 0.70 mPa, 39.70 C, ForVacuum: 0.605 Pa, Gas: NULL, GasValve: 0.00 V 16:50:30 #36369 /VacuumLog: Chamber: 0.64 mPa, 39.70 C, ForVacuum: 0.475 Pa, Gas: NULL, GasValve: 0.00 V 16:50:34 #36369 /VacuumLog: Chamber: 0.62 mPa, 39.70 C, ForVacuum: 0.45 Pa, Gas: NULL, GasValve: 0.00 V 16:50:37 #36369 /VacuumLog: Chamber: 0.60 mPa, 39.70 C, ForVacuum: 0.45 Pa, Gas: NULL, GasValve: 0.00 V 16:50:41 #36369 /VacuumLog: Chamber: 0.59 mPa, 39.70 C, ForVacuum: 0.45 Pa, Gas: NULL, GasValve: 0.00 V 16:50:44 #36369 /VacuumLog: Chamber: 0.58 mPa, 39.70 C, ForVacuum: 0.455 Pa, Gas: NULL, GasValve: 0.00 V 16:50:44 #36369 Papouch-Za/LOC_RawDataAcquiring: Papouch-Za: End of acquiring 16:50:48 #36369 /VacuumLog: Chamber: 0.57 mPa, 39.70 C, ForVacuum: 0.46 Pa, Gas: NULL, GasValve: 0.00 V 16:50:50 #36369 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 16:50:50 #36369 /DischargeFunction: General Calling PublishOnStageTasks 16:50:51 #36369 /VacuumLog: Chamber: 0.56 mPa, 39.70 C, ForVacuum: 0.46 Pa, Gas: NULL, GasValve: 0.00 V 16:50:54 #36369 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 16:50:54 #36369 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 16:50:55 #36369 /VacuumLog: Chamber: 0.56 mPa, 39.70 C, ForVacuum: 0.465 Pa, Gas: NULL, GasValve: 0.00 V 16:50:57 #36369 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 16:50:58 #36369 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 16:50:58 #36369 /VacuumLog: Chamber: 0.56 mPa, 39.60 C, ForVacuum: 0.465 Pa, Gas: NULL, GasValve: 0.00 V 16:51:02 #36369 /VacuumLog: Chamber: 0.55 mPa, 39.70 C, ForVacuum: 0.465 Pa, Gas: NULL, GasValve: 0.00 V 16:51:05 #36369 /VacuumLog: Chamber: 0.60 mPa, 39.60 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V 16:51:09 #36369 /VacuumLog: Chamber: 0.55 mPa, 39.60 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V 16:51:13 #36369 /VacuumLog: Chamber: 0.55 mPa, 39.60 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V 16:51:16 #36369 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 16:51:16 #36369 /DischargeFunction: General Calling PublishFinally 16:51:16 #36369 /VacuumLog: Chamber: 0.54 mPa, 39.60 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V 16:51:20 #36369 /VacuumLog: Chamber: 0.54 mPa, 39.60 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V