\(\def\sub#1{_\mathrm{#1}}\def\sup#1{^\mathrm{#1}}\def\maximum#1{max_#1}\) Golem #36450

Tokamak GOLEM - Shot Database - #36450

The date of discharge execution21-04-07 17:23:38 [Shot logbook]
The session missionGOLEM --> EDU
The session ID36424
The discharge commentBiasing probe 20mm inner with respect to #36443, double rake probe 65 mm whole session, petiprobe 70 mm whole session
Discharge command./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 0 --comment "Biasing probe 20mm inner with respect to #36443, double rake probe 65 mm whole session, petiprobe 70 mm whole session" --diagnostics_biasingelectrode "5000,0;8000,20;11000,-20;14000,0" --ScanDefinition "36443 36444 36445 36446 36448 36449"

     Technological parameters

    No Plasma:

Basic Diagnostics    

On stage diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 

         



 

         



 

         



 

Other diagnostics

Data flowmeasurement →digitization →analysis →
NameExperiment setupData acquistition systemRaw dataAnalysis results
         



 

         



 

         



 

Name Python3 Gnuplot Octave Matlab Mathematica

Infrastructure







Scan issues

for 36443 36444 36445 36446 36448 36449 + 36450







#36443     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe test, plasma - full steam" --diagnostics_biasingelectrode "5000,0;8000,-20;11000,20;14000,0" --ScanDefinition ""
#36444     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe test, plasma - full steam 5mm inner " --diagnostics_biasingelectrode "5000,0;8000,-20;11000,20;14000,0" --ScanDefinition ""
#36445     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe 10mm inner, rake probe 65 " --diagnostics_biasingelectrode "5000,0;8000,-20;11000,20;14000,0" --ScanDefinition ""
#36446     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe 15mm inner, rake probe 65 " --diagnostics_biasingelectrode "5000,0;8000,-20;11000,20;14000,0" --ScanDefinition ""
#36448     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe 20mm inner, rake probe 65 " --diagnostics_biasingelectrode "5000,0;8000,-20;11000,20;14000,0" --ScanDefinition ""
#36449     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 10 --comment "Biasing probe 20mm inner, rake probe 65, changed polarity " --diagnostics_biasingelectrode "5000,0;8000,20;11000,-20;14000,0" --ScanDefinition ""
#36450     ./Dirigent.sh --discharge --UBt 800 --TBt 0 --Ucd 450 --Tcd 1000 --preionization 1 --gas H --pressure 0 --comment "Biasing probe 20mm inner with respect to #36443, double rake probe 65 mm whole session, petiprobe 70 mm whole session" --diagnostics_biasingelectrode "5000,0;8000,20;11000,-20;14000,0" --ScanDefinition "36443 36444 36445 36446 36448 36449"

Acknowledgement


Thanks to the specific help

The tokamak GOLEM controll SW @