Golem shot: 3648

2010-09-24 - 092117

Basic parameters:
  • Chamber pressure pchamber : 6.46->5.62 mPa (request: 20 mp)
  • Chamber temperature: 92 grad C
  • CBt capacitors (23 mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 353 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.69 over 4.25 to 13.94 [ms]
  • Mean toroidal magnetic field Bt: 0.196 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: 7.8 V
  • Break down voltage: 13.1 V
  • Plasma total charge: 4.5 C
  • Ohmic heating power: 8.6 kW
  • Q edge: 16.1
  • Central electron temperature: 12.0 eV

Thanks to the specific help and