13:48:57 #36497 Discharge/PrepareDischargeEnv@SHM: Command Line Request: 13:48:58 #36497 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 13:48:58 #36497 /GetReadyTheDischarge: Going with gas pressure 10 13:48:58 #36497 /GetReadyTheDischarge: Going with gas type H 13:48:58 #36497 /GetReadyTheDischarge: Discharge with Hydrogen request 13:48:58 #36497 /GetReadyTheDischarge: Discharge with 10 mPa request with GetReadyTheDischarge 13:48:58 #36497 /GetReadyTheDischarge: Diving into .. 13:48:58 #36497 /GetReadyTheDischarge: Going with Bt_orientation CW 13:48:58 #36497 /GetReadyTheDischarge: Discharge with Bt CW request 13:48:59 #36497 /GetReadyTheDischarge: Going with CD_orientation CW 13:48:59 #36497 /GetReadyTheDischarge: Discharge with CD CW request 13:48:59 #36497 /VacuumLog: Chamber: 0.41 mPa, 32.70 C, ForVacuum: 0.405 Pa, Gas: H2, GasValve: 21.22 V 13:49:03 #36497 /VacuumLog: Chamber: 8.59 mPa, 32.70 C, ForVacuum: 0.9 Pa, Gas: H2, GasValve: 22.23 V 13:49:06 #36497 /GetReadyTheDischarge: Bt capacitor charging started 13:49:06 #36497 /VacuumLog: Chamber: 14.00 mPa, 32.70 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 20.98 V 13:49:10 #36497 /VacuumLog: Chamber: 10.70 mPa, 32.70 C, ForVacuum: 2.95 Pa, Gas: H2, GasValve: 20.65 V 13:49:10 #36497 /GetReadyTheDischarge: Cd capacitor charging started 13:49:10 #36497 /ChargingResistorsAllOFF: Diving into .. 13:49:10 #36497 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 13:49:10 #36497 /GetReadyTheDischarge: U_Et: 450, Hrana: 98 13:49:11 #36497 /GetReadyTheDischarge: Charging ... HV=-15 V 13:49:11 #36497 /GetReadyTheDischarge: Charging ... HV=-15 V 13:49:11 #36497 /GetReadyTheDischarge: Charging ... HV=-15 V 13:49:12 #36497 /GetReadyTheDischarge: Charging ... HV=3 V 13:49:12 #36497 /GetReadyTheDischarge: Charging ... HV=3 V 13:49:13 #36497 /GetReadyTheDischarge: Charging ... HV=37 V 13:49:13 #36497 /GetReadyTheDischarge: Charging ... HV=37 V 13:49:14 #36497 /GetReadyTheDischarge: Charging ... HV=37 V 13:49:14 #36497 /VacuumLog: Chamber: 10.20 mPa, 32.80 C, ForVacuum: 2.75 Pa, Gas: H2, GasValve: 20.59 V 13:49:14 #36497 /GetReadyTheDischarge: Charging ... HV=71 V 13:49:14 #36497 /GetReadyTheDischarge: Charging ... HV=71 V 13:49:15 #36497 /GetReadyTheDischarge: Charging ... HV=106 V 13:49:15 #36497 /GetReadyTheDischarge: Charging ... HV=106 V 13:49:16 #36497 /GetReadyTheDischarge: Charging ... HV=106 V 13:49:16 #36497 /GetReadyTheDischarge: Charging ... HV=138 V 13:49:17 #36497 /GetReadyTheDischarge: Charging ... HV=138 V 13:49:17 #36497 /GetReadyTheDischarge: Charging ... HV=171 V 13:49:17 #36497 /GetReadyTheDischarge: Charging ... HV=171 V Gas: H2, GasValve: 20.59 V 13:49:18 #36497 /GetReadyTheDischarge: Charging ... HV=204 V 13:49:18 #36497 /GetReadyTheDischarge: Charging ... HV=204 V 13:49:19 #36497 /GetReadyTheDischarge: Charging ... HV=204 V 13:49:19 #36497 /GetReadyTheDischarge: Charging ... HV=236 V 13:49:20 #36497 /GetReadyTheDischarge: Charging ... HV=236 V 13:49:20 #36497 /GetReadyTheDischarge: Charging ... HV=267 V 13:49:21 #36497 /GetReadyTheDischarge: Charging ... HV=267 V 13:49:21 #36497 /GetReadyTheDischarge: Charging ... HV=267 V 13:49:21 #36497 /GetReadyTheDischarge: Charging ... HV=298 V 13:49:22 #36497 /GetReadyTheDischarge: Charging ... HV=298 V 13:49:22 #36497 /GetReadyTheDischarge: Charging ... HV=328 V 13:49:23 #36497 /GetReadyTheDischarge: Charging ... HV=328 V 13:49:23 #36497 /GetReadyTheDischarge: Charging ... HV=328 V 13:49:24 #36497 /GetReadyTheDischarge: Charging ... HV=356 V 13:49:24 #36497 /GetReadyTheDischarge: Charging ... HV=356 V 13:49:24 #36497 /VacuumLog: Chamber: 9.81 mPa, 32.70 C, ForVacuum: 2.6 Pa, Gas: H2, GasValve: 20.59 V 13:49:24 #36497 /GetReadyTheDischarge: Charging ... HV=383 V 13:49:25 #36497 /GetReadyTheDischarge: Charging ... HV=383 V 13:49:25 #36497 /GetReadyTheDischarge: Charging ... HV=383 V 13:49:26 #36497 /GetReadyTheDischarge: Charging ... HV=409 V 13:49:26 #36497 /GetReadyTheDischarge: Charging ... HV=409 V 13:49:27 #36497 /GetReadyTheDischarge: Charging ... HV=435 V 13:49:27 #36497 /GetReadyTheDischarge: Charging ... HV=435 V 13:49:28 #36497 /GetReadyTheDischarge: Charging ... HV=435 V 13:49:28 #36497 /GetReadyTheDischarge: Charging ... HV=464 V Gas: H2, GasValve: 20.59 V 13:49:28 #36497 /GetReadyTheDischarge: Cd capacitor charging finished @ 464 V 13:49:28 #36497 /GetReadyTheDischarge: Charging ... HV=464 V 13:49:29 #36497 /GetReadyTheDischarge: Charging ... HV=487 V 13:49:29 #36497 /GetReadyTheDischarge: Charging ... HV=487 V 13:49:30 #36497 /GetReadyTheDischarge: Charging ... HV=514 V 13:49:30 #36497 /GetReadyTheDischarge: Charging ... HV=514 V 13:49:31 #36497 /GetReadyTheDischarge: Charging ... HV=514 V 13:49:31 #36497 /GetReadyTheDischarge: Charging ... HV=539 V 13:49:31 #36497 /GetReadyTheDischarge: Charging ... HV=539 V 13:49:32 #36497 /VacuumLog: Chamber: 9.70 mPa, 32.80 C, ForVacuum: 2.55 Pa, Gas: H2, GasValve: 20.59 V 13:49:32 #36497 /GetReadyTheDischarge: Charging ... HV=19 V 13:49:32 #36497 /GetReadyTheDischarge: Charging ... HV=565 V 13:49:33 #36497 /GetReadyTheDischarge: Charging ... HV=565 V 13:49:33 #36497 /GetReadyTheDischarge: Charging ... HV=590 V 13:49:34 #36497 /GetReadyTheDischarge: Charging ... HV=590 V 13:49:34 #36497 /GetReadyTheDischarge: Charging ... HV=590 V 13:49:34 #36497 /GetReadyTheDischarge: Charging ... HV=613 V 13:49:35 #36497 /GetReadyTheDischarge: Charging ... HV=613 V 13:49:35 #36497 /GetReadyTheDischarge: Charging ... HV=635 V Gas: H2, GasValve: 20.59 V 13:49:36 #36497 /GetReadyTheDischarge: Charging ... HV=635 V 13:49:36 #36497 /GetReadyTheDischarge: Charging ... HV=635 V 13:49:36 #36497 /GetReadyTheDischarge: Charging ... HV=657 V 13:49:37 #36497 /GetReadyTheDischarge: Charging ... HV=657 V 13:49:37 #36497 /GetReadyTheDischarge: Charging ... HV=681 V 13:49:38 #36497 /GetReadyTheDischarge: Charging ... HV=681 V 13:49:38 #36497 /GetReadyTheDischarge: Charging ... HV=681 V 13:49:39 #36497 /GetReadyTheDischarge: Charging ... HV=703 V 13:49:39 #36497 /GetReadyTheDischarge: Charging ... HV=703 V Gas: H2, GasValve: 20.59 V 13:49:39 #36497 /GetReadyTheDischarge: Charging ... HV=724 V 13:49:40 #36497 /GetReadyTheDischarge: Charging ... HV=724 V 13:49:40 #36497 /GetReadyTheDischarge: Charging ... HV=724 V 13:49:41 #36497 /GetReadyTheDischarge: Charging ... HV=743 V 13:49:41 #36497 /GetReadyTheDischarge: Charging ... HV=743 V 13:49:42 #36497 /GetReadyTheDischarge: Charging ... HV=762 V 13:49:42 #36497 /GetReadyTheDischarge: Charging ... HV=762 V 13:49:42 #36497 /GetReadyTheDischarge: Charging ... HV=762 V 13:49:43 #36497 /GetReadyTheDischarge: Charging ... HV=781 V 13:49:43 #36497 /GetReadyTheDischarge: Charging ... HV=781 V 13:49:44 #36497 /GetReadyTheDischarge: Charging ... HV=781 V 13:49:44 #36497 /GetReadyTheDischarge: Charging ... HV=800 V 13:49:44 #36497 /ChargingResistorsAllON: Diving into .. 13:49:45 #36497 /GetReadyTheDischarge: Bt capacitor charging finished @ 800 V 13:49:45 #36497 /ChargingResistorsAllON: Diving into .. 13:49:45 #36497 /GetReadyTheDischarge: Ascending from .. 13:49:45 #36497 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 13:49:45 #36497 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 13:49:45 #36497 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 13:49:45 #36497 TektrMSO58-a/LogTheDeviceAction: The 21_RunAways_JCetal action on stage with Arming 13:49:46 #36497 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 13:49:46 #36497 /VacuumLog: Chamber: 9.60 mPa, 32.80 C, ForVacuum: 2.55 Pa, Gas: H2, GasValve: 20.59 V 13:49:49 #36497 /VacuumLog: Chamber: 9.61 mPa, 32.80 C, ForVacuum: 2.55 Pa, Gas: H2, GasValve: 20.59 V 13:49:53 #36497 /VacuumLog: Chamber: 9.61 mPa, 32.80 C, ForVacuum: 2.5 Pa, Gas: H2, GasValve: 20.59 V 13:49:56 #36497 /Trigger: Going through .. 13:49:56 #36497 Discharge/HWTrigger: Going through .. 13:49:56 #36497 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 13:49:56 #36497 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 13:49:56 #36497 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 13:49:57 #36497 /VacuumLog: Chamber: 9.60 mPa, 32.80 C, ForVacuum: 2.5 Pa, Gas: H2, GasValve: 20.59 V 13:49:59 #36497 /ChargingResistorsAllON: Diving into .. 13:50:00 #36497 /VacuumLog: Chamber: 7.18 mPa, 32.80 C, ForVacuum: 2.35 Pa, Gas: NULL, GasValve: 0.00 V 13:50:01 #36497 /SecurePostDischargeState: Going through .. 13:50:01 #36497 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 13:50:04 #36497 /VacuumLog: Chamber: 0.80 mPa, 32.80 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 13:50:04 #36497 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 13:50:07 #36497 /VacuumLog: Chamber: 0.64 mPa, 32.80 C, ForVacuum: 0.47 Pa, Gas: NULL, GasValve: 0.00 V 13:50:11 #36497 /VacuumLog: Chamber: 0.59 mPa, 32.80 C, ForVacuum: 0.39 Pa, Gas: NULL, GasValve: 0.00 V 13:50:13 #36497 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 13:50:13 #36497 /DischargeFunction: General Calling PublishOnStageTasks 13:50:14 #36497 /VacuumLog: Chamber: 0.55 mPa, 32.80 C, ForVacuum: 0.38 Pa, Gas: NULL, GasValve: 0.00 V 13:50:18 #36497 /VacuumLog: Chamber: 0.53 mPa, 32.90 C, ForVacuum: 0.385 Pa, Gas: NULL, GasValve: 0.00 V 13:50:21 #36497 /VacuumLog: Chamber: 0.51 mPa, 32.80 C, ForVacuum: 0.385 Pa, Gas: NULL, GasValve: 0.00 V 13:50:25 #36497 /VacuumLog: Chamber: 0.50 mPa, 33.00 C, ForVacuum: 0.39 Pa, Gas: NULL, GasValve: 0.00 V 13:50:27 #36497 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 13:50:27 #36497 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 13:50:27 #36497 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 13:50:27 #36497 /DischargeFunction: General Calling PublishFinally 13:50:29 #36497 /VacuumLog: Chamber: 0.49 mPa, 32.90 C, ForVacuum: 0.39 Pa, Gas: NULL, GasValve: 0.00 V 13:50:32 #36497 /VacuumLog: Chamber: 0.48 mPa, 32.80 C, ForVacuum: 0.39 Pa, Gas: NULL, GasValve: 0.00 V 13:50:36 #36497 /VacuumLog: Chamber: 0.49 mPa, 32.80 C, ForVacuum: 0.395 Pa, Gas: NULL, GasValve: 0.00 V