15:52:41 #36956 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Rail probe 15:52:41 #36956 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:52:42 #36956 /VacuumLog: Chamber: 66.20 mPa, 28.80 C, ForVacuum: 6.6 Pa, Gas: NULL, GasValve: 0.00 V 15:52:43 #36956 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 15:52:43 #36956 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge GetReadyTheDischarge: Going with gas type H 15:52:43 15:52:43 #36956 /GetReadyTheDischarge: Discharge with Hydrogen request 15:52:44 #3615:52:44 #36956 /GetReadyTheDischarge: Discharge with 10 mPa request 15:52:44 #36956 /GetReadyTheDischarge: Going with CD_orientation CW 15:52:44 #36956 /GetReadyTheDischarge: Discharge with CD CW request 15:52:44 #36956 /GetReadyTheDischarge: It is a dummy discharge - without Charger action 15:52:46 #36956 /VacuumLog: Chamber: 54.30 mPa, 28.90 C, ForVacuum: 6.35 Pa, Gas: H2, GasValve: 11.54 V 15:52:49 #36956 /GetReadyTheDischarge: Ascending from .. 15:52:50 #36956 /VacuumLog: Chamber: 45.40 mPa, 28.80 C, ForVacuum: 6.15 Pa, Gas: H2, GasValve: 3.93 V 15:52:53 #36956 /VacuumLog: Chamber: 37.30 mPa, 28.80 C, ForVacuum: 5.95 Pa, Gas: H2, GasValve: -4.88 V 15:52:57 #36956 /VacuumLog: Chamber: 32.20 mPa, 28.80 C, ForVacuum: 5.8 Pa, Gas: H2, GasValve: -9.63 V 15:53:00 #36956 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:53:01 #36956 /VacuumLog: Chamber: 28.60 mPa, 28.90 C, ForVacuum: 5.65 Pa, Gas: H2, GasValve: -13.67 V 15:53:02 #36956 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:53:02 #36956 TektrMSO58-a/LogTheDeviceAction: The BallPenProbeFluctPot action on stage with Arming 15:53:02 #36956 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:53:02 #36956 RigolDG1032Z-a.golem/LogTheDeviceAction: The FG4ElstatProbes action on stage with Arming 15:53:02 #36956 TektrMSO64-a/LogTheDeviceAction: The LangRailProbesSweptWithFalco action on stage with Arming 15:53:04 #36956 /VacuumLog: Chamber: 25.70 mPa, 28.90 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: -13.67 V 15:53:06 #36956 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:53:08 #36956 /VacuumLog: Chamber: 23.50 mPa, 28.90 C, ForVacuum: 5.45 Pa, Gas: H2, GasValve: -13.67 V 15:53:12 #36956 /VacuumLog: Chamber: 21.60 mPa, 28.90 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: -13.67 V 15:53:15 #36956 /VacuumLog: Chamber: 20.00 mPa, 28.90 C, ForVacuum: 5.3 Pa, Gas: H2, GasValve: -13.67 V 15:53:18 #36956 /Trigger: Going through .. 15:53:18 #36956 Discharge/HWTrigger: Going through .. 15:53:18 #36956 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 15:53:18 #36956 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 15:53:18 #36956 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 15:53:19 #36956 /VacuumLog: Chamber: 18.50 mPa, 28.90 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: -13.67 V 15:53:23 #36956 /VacuumLog: Chamber: 17.30 mPa, 28.90 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: -13.67 V 15:53:24 #36956 /ChargingResistorsAllON: Diving into .. 15:53:26 #36956 /VacuumLog: Chamber: 16.20 mPa, 28.90 C, ForVacuum: 5.05 Pa, Gas: H2, GasValve: 0.00 V 15:53:26 #36956 /SecurePostDischargeState: Going through .. 15:53:26 #36956 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:53:30 #36956 /VacuumLog: Chamber: 15.20 mPa, 28.90 C, ForVacuum: 5.0 Pa, Gas: NULL, GasValve: 0.00 V 15:53:31 #36956 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:53:34 #36956 /VacuumLog: Chamber: 14.30 mPa, 28.90 C, ForVacuum: 4.95 Pa, Gas: NULL, GasValve: 0.00 V 15:53:37 #36956 TektrMSO58-a/getdata: TektrMSO58-a: Start of acquiring 15:53:37 #36956 /VacuumLog: Chamber: 13.50 mPa, 29.00 C, ForVacuum: 4.85 Pa, Gas: NULL, GasValve: 0.00 V 15:53:37 #36956 TektrMSO58-a/getdata: TektrMSO58-a: End of acquiring 15:53:41 #36956 /VacuumLog: Chamber: 12.80 mPa, 28.90 C, ForVacuum: 4.8 Pa, Gas: NULL, GasValve: 0.00 V 15:53:43 #36956 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:53:44 #36956 /VacuumLog: Chamber: 12.20 mPa, 28.90 C, ForVacuum: 4.75 Pa, Gas: NULL, GasValve: 0.00 V 15:53:47 #36956 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:53:48 #36956 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:53:48 #36956 /VacuumLog: Chamber: 11.60 mPa, 28.90 C, ForVacuum: 4.7 Pa, Gas: NULL, GasValve: 0.00 V 15:53:52 #36956 /VacuumLog: Chamber: 11.00 mPa, 28.90 C, ForVacuum: 4.6 Pa, Gas: NULL, GasValve: 0.00 V 15:53:55 #36956 /VacuumLog: Chamber: 10.50 mPa, 28.90 C, ForVacuum: 4.55 Pa, Gas: NULL, GasValve: 0.00 V 15:53:59 #36956 /VacuumLog: Chamber: 10.10 mPa, 28.90 C, ForVacuum: 4.5 Pa, Gas: NULL, GasValve: 0.00 V 15:54:03 #36956 /VacuumLog: Chamber: 9.76 mPa, 28.80 C, ForVacuum: 4.45 Pa, Gas: NULL, GasValve: 0.00 V 15:54:06 #36956 /VacuumLog: Chamber: 9.45 mPa, 29.00 C, ForVacuum: 4.4 Pa, Gas: NULL, GasValve: 0.00 V 15:54:10 #36956 /VacuumLog: Chamber: 9.18 mPa, 28.90 C, ForVacuum: 4.35 Pa, Gas: NULL, GasValve: 0.00 V 15:54:13 #36956 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:54:13 #36956 /VacuumLog: Chamber: 8.94 mPa, 28.90 C, ForVacuum: 4.35 Pa, Gas: NULL, GasValve: 0.00 V 15:54:15 #36956 /DischargeFunction: General Calling FinalDischargeOperations 15:54:17 #36956 /VacuumLog: Chamber: 8.72 mPa, 28.90 C, ForVacuum: 4.3 Pa, Gas: NULL, GasValve: 0.00 V