10:33:57 #36978 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position studies 10:33:57 #36978 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 10:33:59 #36978 /VacuumLog: Chamber: 1.25 mPa, 31.10 C, ForVacuum: 2.15 Pa, Gas: NULL, GasValve: 0.00 V 10:33:59 #36978 /GetReadyTheDischarge: Going with gas pressure 10 10:33:59 #36978 /GetReadyTheDischarge: Going with gas type H 10:33:59 #36978 /GetReadyTheDischarge: Discharge with Hydrogen request 10:33:59 #36978 /GetReadyTheDischarge: Discharge with 10 mPa request TheDischarge 10:33:59 #36978 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 10:33:59 #36978 /GetReadyTheDischarge: Diving into .. 10:33:59 #36978 /GetReadyTheDischarge: Going with Bt_orientation CW 10:33:59 #36978 /GetReadyTheDischarge: Discharge with Bt CW request 10:34:00 #36978 /GetReadyTheDischarge: Going with CD_orientation CW 10:34:00 #36978 /GetReadyTheDischarge: Discharge with CD CW request 10:34:00 #36978 /GetReadyTheDischarge: It is a dummy discharge - without Charger action 10:34:02 #36978 /VacuumLog: Chamber: 1.25 mPa, 31.10 C, ForVacuum: 2.15 Pa, Gas: H2, GasValve: 21.96 V 10:34:05 #36978 /GetReadyTheDischarge: Ascending from .. 10:34:06 #36978 /VacuumLog: Chamber: 2.91 mPa, 31.10 C, ForVacuum: 2.3 Pa, Gas: H2, GasValve: 23.65 V 10:34:09 #36978 /VacuumLog: Chamber: 12.90 mPa, 31.10 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 24.25 V 10:34:13 #36978 /VacuumLog: Chamber: 12.50 mPa, 31.10 C, ForVacuum: 5.35 Pa, Gas: H2, GasValve: 23.15 V 10:34:17 #36978 /VacuumLog: Chamber: 10.80 mPa, 31.10 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 23.13 V 10:34:20 #36978 /VacuumLog: Chamber: 10.60 mPa, 31.10 C, ForVacuum: 4.95 Pa, Gas: H2, GasValve: 23.13 V 10:34:24 #36978 /VacuumLog: Chamber: 10.40 mPa, 31.10 C, ForVacuum: 4.9 Pa, Gas: H2, GasValve: 23.13 V 10:34:27 #36978 /VacuumLog: Chamber: 10.30 mPa, 31.10 C, ForVacuum: 4.85 Pa, Gas: H2, GasValve: 23.13 V 10:34:30 #36978 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 10:34:31 #36978 /VacuumLog: Chamber: 10.20 mPa, 31.10 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 23.13 V 10:34:31 #36978 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:34:31 #36978 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 10:34:35 #36978 /VacuumLog: Chamber: 10.10 mPa, 31.10 C, ForVacuum: 4.8 Pa, Gas: H2, GasValve: 23.13 V 10:34:35 #36978 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 10:34:38 #36978 /VacuumLog: Chamber: 10.00 mPa, 31.10 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 23.13 V 10:34:42 #36978 /VacuumLog: Chamber: 9.99 mPa, 31.10 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 23.13 V 10:34:45 #36978 /VacuumLog: Chamber: 9.95 mPa, 31.00 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 23.13 V 10:34:46 #36978 /Trigger: Going through .. 10:34:46 #36978 Discharge/HWTrigger: Going through .. 10:34:46 #36978 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 10:34:46 #36978 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 10:34:46 #36978 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 10:34:49 #36978 /VacuumLog: Chamber: 9.91 mPa, 31.10 C, ForVacuum: 4.7 Pa, Gas: H2, GasValve: 23.13 V 10:34:51 #36978 /ChargingResistorsAllON: Diving into .. 10:34:53 #36978 /VacuumLog: Chamber: 2.82 mPa, 31.10 C, ForVacuum: 4.35 Pa, Gas: H2, GasValve: 0.00 V 10:34:53 #36978 /SecurePostDischargeState: Going through .. 10:34:53 #36978 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 10:34:56 #36978 /VacuumLog: Chamber: 1.39 mPa, 31.10 C, ForVacuum: 2.5 Pa, Gas: NULL, GasValve: 0.00 V 10:34:58 #36978 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 10:35:00 #36978 /VacuumLog: Chamber: 1.35 mPa, 31.00 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 10:35:00 #36978 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 10:35:01 #36978 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 10:35:04 #36978 /VacuumLog: Chamber: 1.32 mPa, 31.10 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 10:35:07 #36978 /VacuumLog: Chamber: 1.31 mPa, 31.00 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 10:35:10 #36978 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 10:35:11 #36978 /VacuumLog: Chamber: 1.29 mPa, 31.00 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 10:35:14 #36978 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 10:35:15 #36978 /VacuumLog: Chamber: 1.28 mPa, 31.10 C, ForVacuum: 2.1 Pa, Gas: NULL, GasValve: 0.00 V 10:35:16 #36978 /DischargeFunction: General Calling FinalDischargeOperations