17:08:28 #37089 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 17:08:28 #37089 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:08:30 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:08:30 #37089 /GetReadyTheDischarge: Going with gas pressure 15 17:08:30 #37089 /GetReadyTheDischarge: Going with gas type H 17:08:30 #37089 /GetReadyTheDischarge: Discharge with Hydrogen request 17:08:30 #37089 /GetReadyTheDischarge: Discharge with 15 mPa request charge 17:08:30 #37089 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 17:08:30 #37089 /GetReadyTheDischarge: Diving into .. 17:08:30 #37089 /GetReadyTheDischarge: Going with Bt_orientation CW 17:08:30 #37089 /GetReadyTheDischarge: Discharge with Bt CW request 17:08:31 #37089 /GetReadyTheDischarge: Going with CD_orientation CW 17:08:31 #37089 /GetReadyTheDischarge: Discharge with CD CW request 17:08:33 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:33 #37089 /GetReadyTheDischarge: Bt capacitor charging not requested 17:08:33 #37089 /GetReadyTheDischarge: Cd capacitor charging not requested 17:08:33 #37089 /GetReadyTheDischarge: U_Bt: 00, Hrana: 98 17:08:33 #37089 /GetReadyTheDischarge: U_Et: 0, Hrana: 98 17:08:34 #37089 /ChargingResistorsAllON: Diving into .. 17:08:34 #37089 /GetReadyTheDischarge: Ascending from .. 17:08:37 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:40 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:44 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:48 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:50 #37089 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:08:51 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:52 #37089 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:08:52 #37089 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:08:55 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:08:56 #37089 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:08:59 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:09:02 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:09:06 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:09:07 #37089 /Trigger: Going through .. 17:09:07 #37089 Discharge/HWTrigger: Going through .. 17:09:07 #37089 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 17:09:07 #37089 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:09:07 #37089 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 17:09:10 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.20 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 20.66 V 17:09:12 #37089 /ChargingResistorsAllON: Diving into .. 17:09:13 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: H2, GasValve: 0.00 V 17:09:15 #37089 /SecurePostDischargeState: Going through .. 17:09:15 #37089 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:09:17 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:20 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.00 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:24 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.00 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:28 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.00 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:29 #37089 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:09:31 #37089 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 17:09:31 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.00 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:32 #37089 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 17:09:35 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:38 #37089 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:09:39 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.00 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:42 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:46 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:50 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:53 #37089 /VacuumLog: Chamber: 34400.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:09:57 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:10:00 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.20 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:10:04 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:10:08 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.20 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V 17:10:09 #37089 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:10:11 #37089 /DischargeFunction: General Calling FinalDischargeOperations 17:10:11 #37089 /VacuumLog: Chamber: 34500.00 mPa, 34.10 C, ForVacuum: 1450.0 Pa, Gas: NULL, GasValve: 0.00 V