18:13:47 #37095 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 18:13:48 #37095 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 18:13:50 #37095 /GetReadyTheDischarge: Going with gas pressure 15 18:13:50 #37095 /GetReadyTheDischarge: Going with gas type H 18:13:50 #37095 /GetReadyTheDischarge: Discharge with Hydrogen request 18:13:50 #37095 /GetReadyTheDischarge: Discharge with 15 mPa request TheDischarge 18:13:50 #37095 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 18:13:50 #37095 /GetReadyTheDischarge: Diving into .. 18:13:50 #37095 /GetReadyTheDischarge: Going with Bt_orientation CW 18:13:50 #37095 /GetReadyTheDischarge: Discharge with Bt CW request 18:13:50 #37095 /GetReadyTheDischarge: Going with CD_orientation CW 18:13:51 #37095 /GetReadyTheDischarge: Discharge with CD CW request 18:13:51 #37095 /VacuumLog: Chamber: 0.76 mPa, 34.90 C, ForVacuum: 1.85 Pa, Gas: H2, GasValve: 22.03 V 18:13:53 #37095 /GetReadyTheDischarge: Bt capacitor charging not requested 18:13:53 #37095 /GetReadyTheDischarge: Cd capacitor charging not requested 18:13:53 #37095 /GetReadyTheDischarge: U_Bt: 00, Hrana: 98 18:13:53 #37095 /GetReadyTheDischarge: U_Et: 0, Hrana: 98 18:13:54 #37095 /ChargingResistorsAllON: Diving into .. 18:13:54 #37095 /GetReadyTheDischarge: Ascending from .. 18:13:55 #37095 /VacuumLog: Chamber: 2.91 mPa, 34.90 C, ForVacuum: 2.05 Pa, Gas: H2, GasValve: 24.65 V 18:13:58 #37095 /VacuumLog: Chamber: 14.40 mPa, 34.90 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 25.82 V 18:14:02 #37095 /VacuumLog: Chamber: 15.10 mPa, 34.80 C, ForVacuum: 5.5 Pa, Gas: H2, GasValve: 25.17 V 18:14:05 #37095 /VacuumLog: Chamber: 15.00 mPa, 34.90 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.30 V 18:14:06 #37095 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 18:14:08 #37095 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:14:08 #37095 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 18:14:09 #37095 /VacuumLog: Chamber: 15.10 mPa, 34.90 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.30 V 18:14:12 #37095 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 18:14:13 #37095 /VacuumLog: Chamber: 15.00 mPa, 34.80 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.30 V 18:14:16 #37095 /VacuumLog: Chamber: 15.00 mPa, 34.90 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.30 V 18:14:20 #37095 /VacuumLog: Chamber: 15.10 mPa, 34.80 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.30 V 18:14:23 #37095 /Trigger: Going through .. 18:14:23 #37095 Discharge/HWTrigger: Going through .. 18:14:23 #37095 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 18:14:23 #37095 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 18:14:23 #37095 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 18:14:24 #37095 /VacuumLog: Chamber: 15.10 mPa, 34.80 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.30 V 18:14:27 #37095 /ChargingResistorsAllON: Diving into .. 18:14:27 #37095 /VacuumLog: Chamber: 15.10 mPa, 34.90 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.30 V 18:14:30 #37095 /SecurePostDischargeState: Going through .. 18:14:30 #37095 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 18:14:31 #37095 /VacuumLog: Chamber: 1.13 mPa, 34.80 C, ForVacuum: 3.7 Pa, Gas: NULL, GasValve: 0.00 V 18:14:34 #37095 /VacuumLog: Chamber: 0.96 mPa, 34.80 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 18:14:35 #37095 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 18:14:37 #37095 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 18:14:37 #37095 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 18:14:38 #37095 /VacuumLog: Chamber: 0.92 mPa, 34.80 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 18:14:42 #37095 /VacuumLog: Chamber: 0.90 mPa, 34.80 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 18:14:44 #37095 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 18:14:45 #37095 /VacuumLog: Chamber: 0.88 mPa, 34.80 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 18:14:49 #37095 /VacuumLog: Chamber: 0.86 mPa, 34.80 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 18:14:53 #37095 /VacuumLog: Chamber: 0.85 mPa, 34.80 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 18:14:56 #37095 /VacuumLog: Chamber: 0.84 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:00 #37095 /VacuumLog: Chamber: 0.83 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:04 #37095 /VacuumLog: Chamber: 0.82 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:07 #37095 /VacuumLog: Chamber: 0.82 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:11 #37095 /VacuumLog: Chamber: 0.81 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:15 #37095 /VacuumLog: Chamber: 0.81 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:18 #37095 /VacuumLog: Chamber: 0.80 mPa, 34.90 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:22 #37095 /VacuumLog: Chamber: 0.80 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:25 #37095 /VacuumLog: Chamber: 0.79 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:29 #37095 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 18:15:29 #37095 /VacuumLog: Chamber: 0.79 mPa, 34.80 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 18:15:30 #37095 /DischargeFunction: General Calling FinalDischargeOperations