19:16:31 #37100 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 19:16:31 #37100 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 19:16:32 #37100 /VacuumLog: Chamber: 0.57 mPa, 35.20 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 19:16:33 #37100 /GetReadyTheDischarge: Going with gas pressure 15 19:16:33 #37100 /GetReadyTheDischarge: Going with gas type H 19:16:33 #37100 /GetReadyTheDischarge: Discharge with Hydrogen request 19:16:33 #37100 /GetReadyTheDischarge: Discharge with 15 mPa request TheDischarge 19:16:33 #37100 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 19:16:33 #37100 /GetReadyTheDischarge: Diving into .. 19:16:33 #37100 /GetReadyTheDischarge: Going with Bt_orientation CW 19:16:33 #37100 /GetReadyTheDischarge: Discharge with Bt CW request 19:16:34 #37100 /GetReadyTheDischarge: Going with CD_orientation CW 19:16:34 #37100 /GetReadyTheDischarge: Discharge with CD CW request 19:16:36 #37100 /VacuumLog: Chamber: 0.57 mPa, 35.20 C, ForVacuum: 1.65 Pa, Gas: H2, GasValve: 23.50 V 19:16:36 #37100 /GetReadyTheDischarge: Bt capacitor charging not requested 19:16:36 #37100 /GetReadyTheDischarge: Cd capacitor charging not requested 19:16:36 #37100 /GetReadyTheDischarge: U_Bt: 00, Hrana: 98 19:16:36 #37100 /GetReadyTheDischarge: U_Et: 0, Hrana: 98 19:16:37 #37100 /ChargingResistorsAllON: Diving into .. 19:16:37 #37100 /GetReadyTheDischarge: Ascending from .. 19:16:40 #37100 /VacuumLog: Chamber: 4.14 mPa, 35.20 C, ForVacuum: 1.95 Pa, Gas: H2, GasValve: 26.27 V 19:16:43 #37100 /VacuumLog: Chamber: 24.60 mPa, 35.20 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 25.95 V 19:16:47 #37100 /VacuumLog: Chamber: 12.30 mPa, 35.20 C, ForVacuum: 5.7 Pa, Gas: H2, GasValve: 25.31 V 19:16:49 #37100 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 19:16:51 #37100 /VacuumLog: Chamber: 15.70 mPa, 35.20 C, ForVacuum: 5.45 Pa, Gas: H2, GasValve: 25.85 V 19:16:51 #37100 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 19:16:51 #37100 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 19:16:54 #37100 /VacuumLog: Chamber: 15.80 mPa, 35.20 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.85 V 19:16:55 #37100 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 19:16:58 #37100 /VacuumLog: Chamber: 15.70 mPa, 35.20 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.85 V 19:17:02 #37100 /VacuumLog: Chamber: 15.60 mPa, 35.20 C, ForVacuum: 5.6 Pa, Gas: H2, GasValve: 25.85 V 19:17:05 #37100 /VacuumLog: Chamber: 15.60 mPa, 35.20 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.85 V 19:17:06 #37100 /Trigger: Going through .. 19:17:06 #37100 Discharge/HWTrigger: Going through .. 19:17:06 #37100 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 19:17:06 #37100 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 19:17:06 #37100 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 19:17:09 #37100 /VacuumLog: Chamber: 15.60 mPa, 35.20 C, ForVacuum: 5.55 Pa, Gas: H2, GasValve: 25.85 V 19:17:10 #37100 /ChargingResistorsAllON: Diving into .. 19:17:13 #37100 /VacuumLog: Chamber: 3.33 mPa, 35.20 C, ForVacuum: 5.15 Pa, Gas: H2, GasValve: 0.00 V 19:17:13 #37100 /SecurePostDischargeState: Going through .. 19:17:13 #37100 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 19:17:16 #37100 /VacuumLog: Chamber: 0.74 mPa, 35.20 C, ForVacuum: 2.3 Pa, Gas: NULL, GasValve: 0.00 V 19:17:18 #37100 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 19:17:20 #37100 /VacuumLog: Chamber: 0.68 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:20 #37100 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 19:17:21 #37100 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 19:17:24 #37100 /VacuumLog: Chamber: 0.66 mPa, 35.20 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 19:17:27 #37100 /VacuumLog: Chamber: 0.64 mPa, 35.20 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 19:17:30 #37100 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 19:17:31 #37100 /VacuumLog: Chamber: 0.63 mPa, 35.20 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 19:17:35 #37100 /VacuumLog: Chamber: 0.62 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:38 #37100 /VacuumLog: Chamber: 0.61 mPa, 35.10 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:42 #37100 /VacuumLog: Chamber: 0.60 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:46 #37100 /VacuumLog: Chamber: 0.60 mPa, 35.10 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:49 #37100 /VacuumLog: Chamber: 0.59 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:53 #37100 /VacuumLog: Chamber: 0.60 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:17:57 #37100 /VacuumLog: Chamber: 0.59 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:18:00 #37100 /VacuumLog: Chamber: 0.59 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:18:04 #37100 /VacuumLog: Chamber: 0.58 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:18:07 #37100 /VacuumLog: Chamber: 0.58 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:18:11 #37100 /VacuumLog: Chamber: 0.58 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 19:18:12 #37100 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 19:18:14 #37100 /DischargeFunction: General Calling FinalDischargeOperations 19:18:14 #37100 /VacuumLog: Chamber: 0.58 mPa, 35.20 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V