17:00:15 #37130 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Plasma position stabilization 17:00:16 #37130 /VacuumLog: Chamber: 0.52 mPa, 44.30 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:00:16 #37130 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 17:00:18 #37130 /GetReadyTheDischarge: Going with gas pressure 17 17:00:18 #37130 /GetReadyTheDischarge: Going with gas type H 17:00:18 #37130 /GetReadyTheDischarge: Discharge with Hydrogen request 17:00:18 #37130 /GetReadyTheDischarge: Discharge with 17 mPa request TheDischarge 17:00:18 #37130 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 17:00:18 #37130 /GetReadyTheDischarge: Diving into .. 17:00:18 #37130 /GetReadyTheDischarge: Going with Bt_orientation CW 17:00:18 #37130 /GetReadyTheDischarge: Discharge with Bt CW request 17:00:18 #37130 /GetReadyTheDischarge: Going with CD_orientation CW 17:00:18 #37130 /GetReadyTheDischarge: Discharge with CD CW request 17:00:19 #37130 /VacuumLog: Chamber: 0.52 mPa, 44.30 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 22.41 V 17:00:23 #37130 /VacuumLog: Chamber: 3.00 mPa, 44.30 C, ForVacuum: 1.55 Pa, Gas: H2, GasValve: 25.62 V 17:00:25 #37130 /GetReadyTheDischarge: Bt capacitor charging started 17:00:26 #37130 /VacuumLog: Chamber: 31.80 mPa, 44.30 C, ForVacuum: 4.15 Pa, Gas: H2, GasValve: 24.38 V 17:00:30 #37130 /GetReadyTheDischarge: Cd capacitor charging started 17:00:30 #37130 /ChargingResistorsAllOFF: Diving into .. 17:00:30 #37130 /GetReadyTheDischarge: U_Bt: 1000, Hrana: 98 17:00:30 #37130 /GetReadyTheDischarge: U_Et: 600, Hrana: 98 17:00:30 #37130 /GetReadyTheDischarge: Charging ... HV=-12 V 17:00:30 #37130 /GetReadyTheDischarge: Charging ... HV=-12 V 17:00:31 #37130 /GetReadyTheDischarge: Charging ... HV=-12 V 17:00:31 #37130 /GetReadyTheDischarge: Charging ... HV=23 V 17:00:32 #37130 /GetReadyTheDischarge: Charging ... HV=13 V 17:00:32 #37130 /GetReadyTheDischarge: Charging ... HV=60 V 17:00:33 #37130 /GetReadyTheDischarge: Charging ... HV=60 V 17:00:33 #37130 /GetReadyTheDischarge: Charging ... HV=60 V 17:00:33 #37130 /VacuumLog: Chamber: 17.10 mPa, 44.20 C, ForVacuum: 5.8 Pa, Gas: H2, GasValve: 25.07 V 17:00:33 #37130 /GetReadyTheDischarge: Charging ... HV=106 V 17:00:34 #37130 /GetReadyTheDischarge: Charging ... HV=106 V 17:00:34 #37130 /GetReadyTheDischarge: Charging ... HV=151 V 17:00:35 #37130 /GetReadyTheDischarge: Charging ... HV=23 V 17:00:35 #37130 /GetReadyTheDischarge: Charging ... HV=151 V 17:00:36 #37130 /GetReadyTheDischarge: Charging ... HV=196 V 17:00:36 #37130 /GetReadyTheDischarge: Charging ... HV=196 V 17:00:37 #37130 /GetReadyTheDischarge: Charging ... HV=241 V 17:00:37 #37130 /GetReadyTheDischarge: Charging ... HV=241 V , Gas: H2, GasValve: 25.07 V 17:00:37 #37130 /GetReadyTheDischarge: Charging ... HV=283 V 17:00:38 #37130 /GetReadyTheDischarge: Charging ... HV=283 V 17:00:38 #37130 /GetReadyTheDischarge: Charging ... HV=23 V 17:00:39 #37130 /GetReadyTheDischarge: Charging ... HV=326 V 17:00:39 #37130 /GetReadyTheDischarge: Charging ... HV=326 V 17:00:40 #37130 /GetReadyTheDischarge: Charging ... HV=365 V 17:00:40 #37130 /GetReadyTheDischarge: Charging ... HV=365 V 17:00:41 #37130 /GetReadyTheDischarge: Charging ... HV=365 V 17:00:41 #37130 /GetReadyTheDischarge: Charging ... HV=403 V 17:00:41 #37130 /GetReadyTheDischarge: Charging ... HV=403 V 17:00:42 #37130 /GetReadyTheDischarge: Charging ... HV=441 V 17:00:42 #37130 /GetReadyTheDischarge: Charging ... HV=441 V 17:00:43 #37130 /GetReadyTheDischarge: Charging ... HV=23 V 17:00:43 #37130 /GetReadyTheDischarge: Charging ... HV=479 V 17:00:44 #37130 /GetReadyTheDischarge: Charging ... HV=479 V 17:00:44 #37130 /GetReadyTheDischarge: Charging ... HV=514 V 17:00:45 #37130 /GetReadyTheDischarge: Charging ... HV=514 V 17:00:45 #37130 /GetReadyTheDischarge: Charging ... HV=548 V 17:00:45 #37130 /GetReadyTheDischarge: Charging ... HV=548 V 17:00:46 #37130 /GetReadyTheDischarge: Charging ... HV=548 V 17:00:46 #37130 /GetReadyTheDischarge: Charging ... HV=582 V 17:00:47 #37130 /GetReadyTheDischarge: Charging ... HV=582 V 17:00:47 #37130 /GetReadyTheDischarge: Charging ... HV=613 V 17:00:47 #37130 /GetReadyTheDischarge: Cd capacitor charging finished @ 613 V 17:00:48 #37130 /GetReadyTheDischarge: Charging ... HV=613 V 17:00:48 #37130 /VacuumLog: Chamber: 15.80 mPa, 44.20 C, ForVacuum: 5.5 Pa, Gas: H2, GasValve: 25.07 V 17:00:48 #37130 /GetReadyTheDischarge: Charging ... HV=613 V 17:00:49 #37130 /GetReadyTheDischarge: Charging ... HV=644 V 17:00:49 #37130 /GetReadyTheDischarge: Charging ... HV=644 V 17:00:49 #37130 /GetReadyTheDischarge: Charging ... HV=681 V 17:00:50 #37130 /GetReadyTheDischarge: Charging ... HV=681 V 17:00:50 #37130 /GetReadyTheDischarge: Charging ... HV=681 V 17:00:51 #37130 /GetReadyTheDischarge: Charging ... HV=714 V 17:00:51 #37130 /GetReadyTheDischarge: Charging ... HV=714 V 17:00:52 #37130 /GetReadyTheDischarge: Charging ... HV=746 V , Gas: H2, GasValve: 25.07 V 17:00:52 #37130 /GetReadyTheDischarge: Charging ... HV=746 V 17:00:52 #37130 /GetReadyTheDischarge: Charging ... HV=746 V 17:00:53 #37130 /GetReadyTheDischarge: Charging ... HV=776 V 17:00:53 #37130 /GetReadyTheDischarge: Charging ... HV=776 V 17:00:54 #37130 /GetReadyTheDischarge: Charging ... HV=806 V 17:00:54 #37130 /GetReadyTheDischarge: Charging ... HV=23 V 17:00:55 #37130 /GetReadyTheDischarge: Charging ... HV=836 V 17:00:55 #37130 /GetReadyTheDischarge: Charging ... HV=836 V , Gas: H2, GasValve: 25.07 V 17:00:56 #37130 /GetReadyTheDischarge: Charging ... HV=836 V 17:00:56 #37130 /GetReadyTheDischarge: Charging ... HV=864 V 17:00:56 #37130 /GetReadyTheDischarge: Charging ... HV=864 V 17:00:57 #37130 /GetReadyTheDischarge: Charging ... HV=894 V 17:00:57 #37130 /GetReadyTheDischarge: Charging ... HV=894 V 17:00:58 #37130 /GetReadyTheDischarge: Charging ... HV=894 V 17:00:58 #37130 /GetReadyTheDischarge: Charging ... HV=920 V 17:00:59 #37130 /GetReadyTheDischarge: Charging ... HV=920 V 17:00:59 #37130 /GetReadyTheDischarge: Charging ... HV=948 V Gas: H2, GasValve: 25.07 V 17:00:59 #37130 /GetReadyTheDischarge: Charging ... HV=948 V 17:01:00 #37130 /GetReadyTheDischarge: Charging ... HV=948 V 17:01:00 #37130 /GetReadyTheDischarge: Charging ... HV=974 V 17:01:01 #37130 /GetReadyTheDischarge: Charging ... HV=974 V 17:01:01 #37130 /GetReadyTheDischarge: Charging ... HV=999 V 17:01:01 #37130 /GetReadyTheDischarge: Bt slow PowSup 17:01:01 #37130 /ChargingResistorsAllON: Diving into .. 17:01:02 #37130 /GetReadyTheDischarge: Charging ... HV=999 V 17:01:02 #37130 /GetReadyTheDischarge: Charging ... HV=1018 V 17:01:03 #37130 /ChargingResistorsAllON: Diving into .. 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:03 #37130 /GetReadyTheDischarge: Bt capacitor charging finished @ 1018 V 17:01:03 #37130 /ChargingResistorsAllON: Diving into .. 17:01:03 #37130 /GetReadyTheDischarge: Ascending from .. 17:01:03 #37130 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 17:01:05 #37130 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:01:05 #37130 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 17:01:06 #37130 /VacuumLog: Chamber: 15.40 mPa, 44.10 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:09 #37130 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 17:01:10 #37130 /VacuumLog: Chamber: 15.40 mPa, 44.10 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:13 #37130 /VacuumLog: Chamber: 15.30 mPa, 44.00 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:17 #37130 /VacuumLog: Chamber: 15.30 mPa, 44.00 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:20 #37130 /Trigger: Going through .. 17:01:20 #37130 Discharge/HWTrigger: Going through .. 17:01:20 #37130 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 17:01:20 #37130 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 17:01:20 #37130 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 17:01:20 #37130 /VacuumLog: Chamber: 15.20 mPa, 44.00 C, ForVacuum: 5.4 Pa, Gas: H2, GasValve: 25.07 V 17:01:24 #37130 /VacuumLog: Chamber: 15.40 mPa, 44.00 C, ForVacuum: 5.1 Pa, Gas: H2, GasValve: 25.07 V 17:01:24 #37130 /ChargingResistorsAllON: Diving into .. 17:01:27 #37130 /SecurePostDischargeState: Going through .. 17:01:27 #37130 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 17:01:28 #37130 /VacuumLog: Chamber: 1.29 mPa, 44.10 C, ForVacuum: 3.7 Pa, Gas: NULL, GasValve: 0.00 V 17:01:31 #37130 /VacuumLog: Chamber: 0.85 mPa, 44.10 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 17:01:32 #37130 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 17:01:35 #37130 /VacuumLog: Chamber: 0.78 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:35 #37130 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 17:01:36 #37130 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 17:01:38 #37130 /VacuumLog: Chamber: 0.74 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:42 #37130 /VacuumLog: Chamber: 0.71 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:45 #37130 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 17:01:45 #37130 /VacuumLog: Chamber: 0.69 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:49 #37130 /VacuumLog: Chamber: 0.67 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:53 #37130 /VacuumLog: Chamber: 0.65 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:01:56 #37130 /VacuumLog: Chamber: 0.64 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:00 #37130 /VacuumLog: Chamber: 0.63 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:03 #37130 /VacuumLog: Chamber: 0.62 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:07 #37130 /VacuumLog: Chamber: 0.61 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:11 #37130 /VacuumLog: Chamber: 0.60 mPa, 44.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:14 #37130 /VacuumLog: Chamber: 0.60 mPa, 44.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:18 #37130 /VacuumLog: Chamber: 0.59 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:21 #37130 /VacuumLog: Chamber: 0.58 mPa, 44.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:24 #37130 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 17:02:25 #37130 /VacuumLog: Chamber: 0.58 mPa, 44.10 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:28 #37130 /VacuumLog: Chamber: 0.57 mPa, 44.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:32 #37130 /VacuumLog: Chamber: 0.57 mPa, 43.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 17:02:32 #37130 /DischargeFunction: General Calling FinalDischargeOperations