Golem shot: 3719

2010-09-29 - 112154

Basic parameters:
  • Chamber pressure pchamber : 2.12->19.36 mPa (request: 20 mp)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 3,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 1513 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.95 over 8.94 to 18.89 [ms]
  • Mean toroidal magnetic field Bt: 0.681 T
  • Mean plasma current: 1.2 kA
  • Mean Uloop: 7.5 V
  • Break down voltage: 15.9 V
  • Plasma total charge: 10.4 C
  • Ohmic heating power: 9.0 kW
  • Q edge: 51.2
  • Central electron temperature: 26.5 eV

Thanks to the specific help and