Golem shot: 3741

2010-10-05 - 103824

Basic parameters:
  • Chamber pressure pchamber : 2.92->18.07 mPa (request: 20 mp)
  • Chamber temperature: 2 grad C
  • CBt capacitors (23 mF) charged to: 400 V
  • CBD capacitors (3.6 mF) charged to: 100 V, triggered 4,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 400 V, triggered 2,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 2258 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 9.79 over 3.81 to 13.60 [ms]
  • Mean toroidal magnetic field Bt: 0.203 T
  • Mean plasma current: 1.1 kA
  • Mean Uloop: 7.7 V
  • Break down voltage: 11.6 V
  • Plasma total charge: 4.3 C
  • Ohmic heating power: 8.5 kW
  • Q edge: 16.7
  • Central electron temperature: 24.5 eV

Thanks to the specific help and