Golem shot: 3770

2010-10-12 - 120932

Basic parameters:
  • Chamber pressure pchamber : 1.93->20.51 mPa (request: 20 mp)
  • Chamber temperature: 0 grad C
  • CBt capacitors (23 mF) charged to: 1200 V
  • CBD capacitors (3.6 mF) charged to: 150 V, triggered 3,0 ms after Bt
  • CCD capacitors (11.3 mF) charged to: 600 V, triggered 3,0 ms after Bt
  • charging log: t, UCB, UCBD, UCCD, UCDS, pchamber
  • Time since session beginning: 12695 s
Data (sampling interval Ts=100 kHz):
Plasma parameters:
  • Plasma life from 8.89 over 7.8 to 16.69 [ms]
  • Mean toroidal magnetic field Bt: 0.626 T
  • Mean plasma current: 1.6 kA
  • Mean Uloop: 11.4 V
  • Break down voltage: 14.0 V
  • Plasma total charge: 12.3 C
  • Ohmic heating power: 18.2 kW
  • Q edge: 35.3
  • Central electron temperature: 24.3 eV

Thanks to the specific help and