14:47:23 #37773 Discharge/PrepareDischargeEnv@SHM: Command Line Request: SOC@USA 14:47:24 #37773 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 14:47:24 #37773 /VacuumLog: Chamber: 1.10 mPa, 35.60 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 14:47:26 #37773 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 14:47:26 #37773 /LogTheDeviceAction: The Trigger action on stage with GetReadyThe14:47:26 #37773 /GetReadyTheDischarge: Going with gas type H 14:47:26 #37773 /GetReadyTheDischarge: Discharge with Hydrogen requ14:47:26 #37773 /14:47:26 #37773 /GetReadyTheDischarge: Discharge with 16 mPa req14:47:26 #37773 /GetReadyTheDischarge: Discharge with Bt CW request 14:47:26 #37773 /GetReadyTheDischarge: Going with CD_orientation CW 14:47:26 #37773 /GetReadyTheDischarge: Discharge with CD CW request 14:47:27 #37773 /VacuumLog: Chamber: 1.10 mPa, 35.60 C, ForVacuum: 0.97 Pa, Gas: H2, GasValve: 22.14 V 14:47:31 #37773 /VacuumLog: Chamber: 12.30 mPa, 35.60 C, ForVacuum: 1.55 Pa, Gas: H2, GasValve: 24.66 V 14:47:33 #37773 /GetReadyTheDischarge: Bt capacitor charging started 14:47:35 #37773 /VacuumLog: Chamber: 19.30 mPa, 35.60 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 22.78 V 14:47:37 #37773 /GetReadyTheDischarge: Cd capacitor charging started 14:47:37 #37773 /ChargingResistorsAllOFF: Diving into .. 14:47:37 #37773 /GetReadyTheDischarge: U_Bt: 400, Hrana: 98 14:47:38 #37773 /GetReadyTheDischarge: U_Et: 600, Hrana: 98 14:47:38 #37773 /GetReadyTheDischarge: Charging ... HV=-10 V 14:47:38 #37773 /GetReadyTheDischarge: Charging ... HV=-10 V 14:47:38 #37773 /VacuumLog: Chamber: 16.40 mPa, 35.60 C, ForVacuum: 4.2 Pa, Gas: H2, GasValve: 23.08 V 14:47:39 #37773 /GetReadyTheDischarge: Charging ... HV=-10 V 14:47:39 #37773 /GetReadyTheDischarge: Charging ... HV=19 V 14:47:39 #37773 /GetReadyTheDischarge: Charging ... HV=19 V 14:47:40 #37773 /GetReadyTheDischarge: Charging ... HV=66 V 14:47:40 #37773 /GetReadyTheDischarge: Charging ... HV=66 V 14:47:41 #37773 /GetReadyTheDischarge: Charging ... HV=66 V 14:47:41 #37773 /GetReadyTheDischarge: Charging ... HV=113 V 14:47:42 #37773 /GetReadyTheDischarge: Charging ... HV=113 V 14:47:42 #37773 /GetReadyTheDischarge: Charging ... HV=158 V Gas: H2, GasValve: 22.98 V 14:47:43 #37773 /GetReadyTheDischarge: Charging ... HV=21 V 14:47:43 #37773 /GetReadyTheDischarge: Charging ... HV=158 V 14:47:43 #37773 /GetReadyTheDischarge: Charging ... HV=203 V 14:47:44 #37773 /GetReadyTheDischarge: Charging ... HV=203 V 14:47:44 #37773 /GetReadyTheDischarge: Charging ... HV=248 V 14:47:45 #37773 /GetReadyTheDischarge: Charging ... HV=248 V 14:47:45 #37773 /GetReadyTheDischarge: Charging ... HV=248 V 14:47:46 #37773 /GetReadyTheDischarge: Charging ... HV=291 V 14:47:46 #37773 /GetReadyTheDischarge: Charging ... HV=291 V Gas: H2, GasValve: 22.98 V 14:47:46 #37773 /GetReadyTheDischarge: Charging ... HV=333 V 14:47:47 #37773 /GetReadyTheDischarge: Charging ... HV=333 V 14:47:47 #37773 /GetReadyTheDischarge: Charging ... HV=333 V 14:47:48 #37773 /GetReadyTheDischarge: Charging ... HV=373 V 14:47:48 #37773 /GetReadyTheDischarge: Charging ... HV=373 V 14:47:49 #37773 /GetReadyTheDischarge: Charging ... HV=410 V 14:47:49 #37773 /GetReadyTheDischarge: Bt capacitor charging finished @ 410 V 14:47:49 #37773 /GetReadyTheDischarge: Charging ... HV=410 V 14:47:50 #37773 /GetReadyTheDischarge: Charging ... HV=487 V , Gas: H2, GasValve: 22.98 V 14:47:50 #37773 /GetReadyTheDischarge: Charging ... HV=487 V 14:47:50 #37773 /GetReadyTheDischarge: Charging ... HV=487 V 14:47:51 #37773 /GetReadyTheDischarge: Charging ... HV=790 V 14:47:51 #37773 /ChargingResistorsAllON: Diving into .. 14:47:51 #37773 /GetReadyTheDischarge: Cd capacitor charging finished @ 790 V 14:47:52 #37773 /ChargingResistorsAllON: Diving into .. 14:47:52 #37773 /GetReadyTheDischarge: Ascending from .. 14:47:52 #37773 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 14:47:53 #37773 /VacuumLog: Chamber: 15.20 mPa, 35.60 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 22.98 V 14:47:54 #37773 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:47:54 #37773 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 14:47:54 #37773 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 14:47:57 #37773 /VacuumLog: Chamber: 15.00 mPa, 35.60 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 22.98 V 14:48:00 #37773 /VacuumLog: Chamber: 14.90 mPa, 35.60 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 22.98 V 14:48:04 #37773 /VacuumLog: Chamber: 14.90 mPa, 35.50 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.98 V 14:48:05 #37773 /Trigger: Going through .. 14:48:05 #37773 Discharge/HWTrigger: Going through .. 14:48:05 #37773 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 14:48:05 #37773 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 6000 14:48:05 #37773 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 14:48:08 #37773 /VacuumLog: Chamber: 16.00 mPa, 35.60 C, ForVacuum: 3.8 Pa, Gas: H2, GasValve: 22.98 V 14:48:09 #37773 /ChargingResistorsAllON: Diving into .. 14:48:11 #37773 /VacuumLog: Chamber: 6.14 mPa, 35.60 C, ForVacuum: 3.7 Pa, Gas: H2, GasValve: 0.00 V 14:48:12 #37773 /SecurePostDischargeState: Going through .. 14:48:12 #37773 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 14:48:15 #37773 /VacuumLog: Chamber: 1.64 mPa, 35.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 14:48:17 #37773 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 14:48:19 #37773 /VacuumLog: Chamber: 1.48 mPa, 35.70 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 14:48:20 #37773 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 14:48:21 #37773 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 14:48:22 #37773 /VacuumLog: Chamber: 1.40 mPa, 35.70 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 14:48:26 #37773 /VacuumLog: Chamber: 1.34 mPa, 35.60 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 14:48:29 #37773 /VacuumLog: Chamber: 1.30 mPa, 35.70 C, ForVacuum: 0.965 Pa, Gas: NULL, GasValve: 0.00 V 14:48:30 #37773 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 14:48:33 #37773 /VacuumLog: Chamber: 1.27 mPa, 35.60 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 14:48:37 #37773 /VacuumLog: Chamber: 1.24 mPa, 35.70 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 14:48:40 #37773 /VacuumLog: Chamber: 1.22 mPa, 35.70 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 14:48:41 #37773 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 14:48:44 #37773 /VacuumLog: Chamber: 1.20 mPa, 35.70 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 14:48:48 #37773 /VacuumLog: Chamber: 1.19 mPa, 35.60 C, ForVacuum: 0.97 Pa, Gas: NULL, GasValve: 0.00 V 14:48:48 #37773 /DischargeFunction: General Calling FinalDischargeOperations