15:15:30 #37783 Discharge/PrepareDischargeEnv@SHM: Command Line Request: SOC@USA 15:15:30 #37783 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:15:31 #37783 /VacuumLog: Chamber: 1.04 mPa, 35.00 C, ForVacuum: 0.96 Pa, Gas: NULL, GasValve: 0.00 V 15:15:33 #37783 /LogTheDeviceAction: The Trigger action on stage with GetReadyTheDischarge 15:15:33 #37783 /LogTheDeviceAction: The Preionization action on stage with GetRe15:15:33 #37783 /GetReadyTheDischarge: Going with gas type H 15:15:33 #37783 /GetReadyTheDischarge: Discharge with Hydrogen requ15:15:33 #37783 /15:15:33 #37783 /GetReadyTheDischarge: Discharge with 16 mPa req15:15:33 #37783 /GetReadyTheDischarge: Discharge with Bt CW request 15:15:33 #37783 /GetReadyTheDischarge: Going with CD_orientation CW 15:15:33 #37783 /GetReadyTheDischarge: Discharge with CD CW request 15:15:35 #37783 /VacuumLog: Chamber: 1.13 mPa, 34.90 C, ForVacuum: 0.96 Pa, Gas: H2, GasValve: 22.15 V 15:15:39 #37783 /VacuumLog: Chamber: 14.70 mPa, 35.00 C, ForVacuum: 1.9 Pa, Gas: H2, GasValve: 25.04 V 15:15:40 #37783 /GetReadyTheDischarge: Bt capacitor charging started 15:15:43 #37783 /VacuumLog: Chamber: 21.50 mPa, 35.00 C, ForVacuum: 4.5 Pa, Gas: H2, GasValve: 22.39 V 15:15:44 #37783 /GetReadyTheDischarge: Cd capacitor charging started 15:15:44 #37783 /ChargingResistorsAllOFF: Diving into .. 15:15:45 #37783 /GetReadyTheDischarge: U_Bt: 350, Hrana: 98 15:15:45 #37783 /GetReadyTheDischarge: U_Et: 650, Hrana: 98 15:15:45 #37783 /GetReadyTheDischarge: Charging ... HV=-11 V 15:15:45 #37783 /GetReadyTheDischarge: Charging ... HV=-11 V 15:15:46 #37783 /GetReadyTheDischarge: Charging ... HV=13 V 15:15:46 #37783 /GetReadyTheDischarge: Charging ... HV=13 V 15:15:46 #37783 /VacuumLog: Chamber: 12.80 mPa, 35.00 C, ForVacuum: 4.0 Pa, Gas: H2, GasValve: 23.40 V 15:15:47 #37783 /GetReadyTheDischarge: Charging ... HV=61 V 15:15:47 #37783 /GetReadyTheDischarge: Charging ... HV=61 V 15:15:48 #37783 /GetReadyTheDischarge: Charging ... HV=61 V 15:15:48 #37783 /GetReadyTheDischarge: Charging ... HV=108 V 15:15:49 #37783 /GetReadyTheDischarge: Charging ... HV=108 V 15:15:49 #37783 /GetReadyTheDischarge: Charging ... HV=154 V 15:15:50 #37783 /GetReadyTheDischarge: Charging ... HV=154 V 15:15:50 #37783 /GetReadyTheDischarge: Charging ... HV=199 V 15:15:50 #37783 /GetReadyTheDischarge: Charging ... HV=199 V , Gas: H2, GasValve: 23.70 V 15:15:51 #37783 /GetReadyTheDischarge: Charging ... HV=199 V 15:15:51 #37783 /GetReadyTheDischarge: Charging ... HV=244 V 15:15:52 #37783 /GetReadyTheDischarge: Charging ... HV=244 V 15:15:52 #37783 /GetReadyTheDischarge: Charging ... HV=287 V 15:15:53 #37783 /GetReadyTheDischarge: Charging ... HV=287 V 15:15:53 #37783 /GetReadyTheDischarge: Charging ... HV=331 V 15:15:54 #37783 /GetReadyTheDischarge: Charging ... HV=331 V 15:15:54 #37783 /GetReadyTheDischarge: Charging ... HV=331 V Gas: H2, GasValve: 23.70 V 15:15:55 #37783 /GetReadyTheDischarge: Charging ... HV=370 V 15:15:55 #37783 /GetReadyTheDischarge: Bt capacitor charging finished @ 370 V 15:15:55 #37783 /GetReadyTheDischarge: Charging ... HV=370 V 15:15:56 #37783 /GetReadyTheDischarge: Charging ... HV=419 V 15:15:56 #37783 /GetReadyTheDischarge: Charging ... HV=419 V 15:15:57 #37783 /GetReadyTheDischarge: Charging ... HV=22 V 15:15:57 #37783 /GetReadyTheDischarge: Charging ... HV=696 V 15:15:57 #37783 /ChargingResistorsAllON: Diving into .. 15:15:58 #37783 /GetReadyTheDischarge: Cd capacitor charging finished @ 696 V 15:15:58 #37783 /ChargingResistorsAllON: Diving into .. 15:15:58 #37783 /GetReadyTheDischarge: Ascending from .. 15:15:58 #37783 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:16:00 #37783 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:16:00 #37783 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:16:00 #37783 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:16:01 #37783 /VacuumLog: Chamber: 18.40 mPa, 34.90 C, ForVacuum: 4.45 Pa, Gas: H2, GasValve: 23.70 V 15:16:05 #37783 /VacuumLog: Chamber: 18.30 mPa, 35.00 C, ForVacuum: 4.4 Pa, Gas: H2, GasValve: 23.70 V 15:16:09 #37783 /VacuumLog: Chamber: 18.30 mPa, 35.00 C, ForVacuum: 4.4 Pa, Gas: H2, GasValve: 23.70 V 15:16:11 #37783 /Trigger: Going through .. 15:16:11 #37783 Discharge/HWTrigger: Going through .. 15:16:11 #37783 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 15:16:11 #37783 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 6000 15:16:11 #37783 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 15:16:14 #37783 /VacuumLog: Chamber: 19.50 mPa, 35.00 C, ForVacuum: 4.3 Pa, Gas: H2, GasValve: 23.70 V 15:16:15 #37783 /ChargingResistorsAllON: Diving into .. 15:16:18 #37783 /VacuumLog: Chamber: 4.07 mPa, 35.00 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 0.00 V 15:16:18 #37783 /SecurePostDischargeState: Going through .. 15:16:18 #37783 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:16:21 #37783 /VacuumLog: Chamber: 1.50 mPa, 35.00 C, ForVacuum: 1.55 Pa, Gas: NULL, GasValve: 0.00 V 15:16:23 #37783 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:16:25 #37783 /VacuumLog: Chamber: 1.36 mPa, 35.10 C, ForVacuum: 1.0 Pa, Gas: NULL, GasValve: 0.00 V 15:16:27 #37783 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:16:27 #37783 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:16:29 #37783 /VacuumLog: Chamber: 1.29 mPa, 35.00 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 15:16:33 #37783 /VacuumLog: Chamber: 1.24 mPa, 35.00 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 15:16:35 #37783 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:16:36 #37783 /VacuumLog: Chamber: 1.20 mPa, 35.00 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 15:16:40 #37783 /VacuumLog: Chamber: 1.18 mPa, 35.10 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 15:16:44 #37783 /VacuumLog: Chamber: 1.16 mPa, 35.00 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:16:47 #37783 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:16:48 #37783 /VacuumLog: Chamber: 1.14 mPa, 35.00 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:16:52 #37783 /VacuumLog: Chamber: 1.12 mPa, 35.10 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:16:53 #37783 /DischargeFunction: General Calling FinalDischargeOperations