15:18:14 #37784 Discharge/PrepareDischargeEnv@SHM: Command Line Request: SOC@USA 15:18:14 #37784 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:18:16 #37784 /GetReadyTheDischarge: Going with gas pressure 16 15:18:16 #37784 /GetReadyTheDischarge: Going with gas type H 15:18:16 #37784 /GetReadyTheDischarge: Discharge with Hydrogen request 15:18:16 #37784 /GetReadyTheDischarge: Discharge with 16 mPa request 15:18:17 #37784 /VacuumLog: Chamber: 1.03 mPa, 34.90 C, ForVacuum: 0.955 Pa, Gas: H2, GasValve: 0.00 V #37784 /GetReadyTheDischarge: Discharge with Bt CW request 15:18:16 #37784 /GetReadyTheDischarge: Going with CD_orientation CW 15:18:16 #37784 /GetReadyTheDischarge: Discharge with CD CW request 15:18:20 #37784 /VacuumLog: Chamber: 3.93 mPa, 35.00 C, ForVacuum: 1.1 Pa, Gas: H2, GasValve: 24.94 V 15:18:23 #37784 /GetReadyTheDischarge: Bt capacitor charging started 15:18:24 #37784 /VacuumLog: Chamber: 26.30 mPa, 34.90 C, ForVacuum: 3.55 Pa, Gas: H2, GasValve: 24.15 V 15:18:28 #37784 /GetReadyTheDischarge: Cd capacitor charging started 15:18:28 #37784 /ChargingResistorsAllOFF: Diving into .. 15:18:28 #37784 /GetReadyTheDischarge: U_Bt: 350, Hrana: 98 15:18:28 #37784 /GetReadyTheDischarge: U_Et: 700, Hrana: 98 15:18:28 #37784 /GetReadyTheDischarge: Charging ... HV=-11 V 15:18:29 #37784 /GetReadyTheDischarge: Charging ... HV=-11 V 15:18:29 #37784 /GetReadyTheDischarge: Charging ... HV=6 V 15:18:29 #37784 /GetReadyTheDischarge: Charging ... HV=6 V 15:18:30 #37784 /GetReadyTheDischarge: Charging ... HV=52 V 15:18:31 #37784 /GetReadyTheDischarge: Charging ... HV=52 V 15:18:31 #37784 /GetReadyTheDischarge: Charging ... HV=52 V 15:18:31 #37784 /GetReadyTheDischarge: Charging ... HV=100 V 15:18:32 #37784 /GetReadyTheDischarge: Charging ... HV=100 V 15:18:32 #37784 /GetReadyTheDischarge: Charging ... HV=146 V 15:18:33 #37784 /GetReadyTheDischarge: Charging ... HV=146 V 15:18:33 #37784 /GetReadyTheDischarge: Charging ... HV=191 V 15:18:34 #37784 /GetReadyTheDischarge: Charging ... HV=191 V 15:18:34 #37784 /GetReadyTheDischarge: Charging ... HV=237 V 15:18:36 #37784 /GetReadyTheDischarge: Charging ... HV=280 V 15:18:36 #37784 /VacuumLog: Chamber: 15.60 mPa, 34.90 C, ForVacuum: 4.05 Pa, Gas: H2, GasValve: 23.08 V 15:18:36 #37784 /GetReadyTheDischarge: Charging ... HV=280 V 15:18:37 #37784 /GetReadyTheDischarge: Charging ... HV=325 V 15:18:37 #37784 /GetReadyTheDischarge: Charging ... HV=325 V 15:18:37 #37784 /GetReadyTheDischarge: Charging ... HV=325 V 15:18:38 #37784 /GetReadyTheDischarge: Charging ... HV=365 V 15:18:38 #37784 /GetReadyTheDischarge: Bt capacitor charging finished @ 365 V 15:18:39 #37784 /GetReadyTheDischarge: Charging ... HV=405 V 15:18:39 #37784 /GetReadyTheDischarge: Charging ... HV=405 V 15:18:39 #37784 /GetReadyTheDischarge: Charging ... HV=405 V 15:18:40 #37784 /VacuumLog: Chamber: 15.30 mPa, 34.90 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 23.08 V 15:18:40 #37784 /GetReadyTheDischarge: Charging ... HV=647 V 15:18:40 #37784 /GetReadyTheDischarge: Charging ... HV=647 V 15:18:41 #37784 /GetReadyTheDischarge: Charging ... HV=957 V 15:18:41 #37784 /ChargingResistorsAllON: Diving into .. 15:18:41 #37784 /GetReadyTheDischarge: Cd capacitor charging finished @ 957 V 15:18:42 #37784 /ChargingResistorsAllON: Diving into .. 15:18:42 #37784 /GetReadyTheDischarge: Ascending from .. 15:18:42 #37784 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:18:43 #37784 /VacuumLog: Chamber: 15.20 mPa, 34.90 C, ForVacuum: 3.95 Pa, Gas: H2, GasValve: 23.08 V 15:18:44 #37784 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:18:44 #37784 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:18:44 #37784 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:18:47 #37784 /VacuumLog: Chamber: 15.00 mPa, 34.90 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 23.08 V 15:18:51 #37784 /VacuumLog: Chamber: 14.90 mPa, 34.90 C, ForVacuum: 3.9 Pa, Gas: H2, GasValve: 23.08 V 15:18:54 #37784 /VacuumLog: Chamber: 14.80 mPa, 34.90 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 23.08 V 15:18:55 #37784 /Trigger: Going through .. 15:18:55 #37784 Discharge/HWTrigger: Going through .. 15:18:55 #37784 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 15:18:55 #37784 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 6000 15:18:55 #37784 Discharge/HWTrigger: Going with trigger Tch5 - Tist -1000 15:18:58 #37784 /VacuumLog: Chamber: 18.50 mPa, 34.20 C, ForVacuum: 3.75 Pa, Gas: H2, GasValve: 23.08 V 15:18:59 #37784 /ChargingResistorsAllON: Diving into .. 15:19:02 #37784 /VacuumLog: Chamber: 3.23 mPa, 35.00 C, ForVacuum: 3.5 Pa, Gas: H2, GasValve: 0.00 V 15:19:03 #37784 /SecurePostDischargeState: Going through .. 15:19:06 #37784 /VacuumLog: Chamber: 1.44 mPa, 35.00 C, ForVacuum: 1.3 Pa, Gas: H2, GasValve: 0.00 V 15:19:07 #37784 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:19:09 #37784 /VacuumLog: Chamber: 1.33 mPa, 35.00 C, ForVacuum: 0.975 Pa, Gas: NULL, GasValve: 0.00 V 15:19:12 #37784 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:19:13 #37784 /VacuumLog: Chamber: 1.27 mPa, 35.00 C, ForVacuum: 0.935 Pa, Gas: NULL, GasValve: 0.00 V 15:19:15 #37784 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:19:16 #37784 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:19:17 #37784 /VacuumLog: Chamber: 1.22 mPa, 35.10 C, ForVacuum: 0.94 Pa, Gas: NULL, GasValve: 0.00 V 15:19:20 #37784 /VacuumLog: Chamber: 1.19 mPa, 35.00 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 15:19:24 #37784 /VacuumLog: Chamber: 1.16 mPa, 35.00 C, ForVacuum: 0.945 Pa, Gas: NULL, GasValve: 0.00 V 15:19:24 #37784 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:19:28 #37784 /VacuumLog: Chamber: 1.14 mPa, 35.00 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:19:32 #37784 /VacuumLog: Chamber: 1.12 mPa, 35.00 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:19:35 #37784 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:19:36 #37784 /VacuumLog: Chamber: 1.11 mPa, 35.00 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V 15:19:39 #37784 /VacuumLog: Chamber: 1.10 mPa, 35.00 C, ForVacuum: 0.95 Pa, Gas: NULL, GasValve: 0.00 V 15:19:42 #37784 /DischargeFunction: General Calling FinalDischargeOperations 15:19:43 #37784 /VacuumLog: Chamber: 1.09 mPa, 34.90 C, ForVacuum: 0.955 Pa, Gas: NULL, GasValve: 0.00 V