15:27:04 #38120 Discharge/PrepareDischargeEnv@SHM: Command Line Request: Last TGIF for the road 15:27:05 #38120 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 15:27:07 #38119 /GetReadyTheDischarge: Going with gas pressure 10 15:27:07 #38119 /GetReadyTheDischarge: Going with gas type H 15:27:07 #38119 /GetReadyTheDischarge: Discharge with Hydrogen request 15:27:07 #38119 /GetReadyTheDischarge: Discharge with 10 mPa request 15:27:07 #38119 /VacuumLog: Chamber: 5.87 mPa, 28.60 C, ForVacuum: 2.2 Pa, Gas: H2, GasValve: 0.00 V 15:27:07 #38119 /GetReadyTheDischarge: Diving into .. 15:27:07 #38119 /GetReadyTheDischarge: Going with Bt_orientation CW 15:27:07 #38119 /GetReadyTheDischarge: Discharge with Bt CW request 15:27:07 #38119 /GetReadyTheDischarge: Going with CD_orientation CW 15:27:07 #38119 /GetReadyTheDischarge: Discharge with CD CW request 15:27:11 #38119 /VacuumLog: Chamber: 5.52 mPa, 28.60 C, ForVacuum: 2.15 Pa, Gas: H2, GasValve: 20.78 V 15:27:14 #38119 /GetReadyTheDischarge: Bt capacitor charging started 15:27:14 #38119 /VacuumLog: Chamber: 5.18 mPa, 28.50 C, ForVacuum: 2.15 Pa, Gas: H2, GasValve: 21.72 V 15:27:18 #38119 /VacuumLog: Chamber: 4.90 mPa, 28.50 C, ForVacuum: 2.1 Pa, Gas: H2, GasValve: 23.22 V 15:27:19 #38119 /GetReadyTheDischarge: Cd capacitor charging started 15:27:19 #38119 /ChargingResistorsAllOFF: Diving into .. 15:27:19 #38119 /GetReadyTheDischarge: U_Bt: 220, Hrana: 98 15:27:19 #38119 /GetReadyTheDischarge: U_Et: 220, Hrana: 98 15:27:19 #38119 /GetReadyTheDischarge: Charging ... HV=22 V 15:27:20 #38119 /GetReadyTheDischarge: Charging ... HV=-11 V 15:27:20 #38119 /GetReadyTheDischarge: Charging ... HV=5 V 15:27:20 #38119 /GetReadyTheDischarge: Charging ... HV=5 V 15:27:21 #38119 /GetReadyTheDischarge: Charging ... HV=5 V 15:27:21 #38119 /GetReadyTheDischarge: Charging ... HV=51 V 15:27:22 #38119 /GetReadyTheDischarge: Charging ... HV=51 V 15:27:22 #38119 /GetReadyTheDischarge: Charging ... HV=99 V 15:27:23 #38119 /GetReadyTheDischarge: Charging ... HV=99 V 15:27:23 #38119 /GetReadyTheDischarge: Charging ... HV=146 V 15:27:24 #38119 /GetReadyTheDischarge: Charging ... HV=146 V 15:27:24 #38119 /GetReadyTheDischarge: Charging ... HV=146 V 15:27:24 #38119 /GetReadyTheDischarge: Charging ... HV=192 V 15:27:25 #38119 /GetReadyTheDischarge: Charging ... HV=192 V 15:27:25 #38119 /GetReadyTheDischarge: Charging ... HV=239 V 15:27:25 #38119 /GetReadyTheDischarge: Bt capacitor charging finished @ 239 V 15:27:26 #38119 /ChargingResistorsAllON: Diving into .. 15:27:26 #38119 /GetReadyTheDischarge: Cd capacitor charging finished @ 239 V 15:27:26 #38119 /ChargingResistorsAllON: Diving into .. 15:27:26 #38119 /GetReadyTheDischarge: Ascending from .. 15:27:26 #38120 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 15:27:28 #38120 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:27:28 #38120 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:27:28 #38120 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:27:28 #38120 TektrMSO64-a/LogTheDeviceAction: The 21_SOC_MatyasP_PetrS_PetrM action on stage with Arming 15:27:28 #38120 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 15:27:29 #38119 /VacuumLog: Chamber: 12.40 mPa, 28.50 C, ForVacuum: 2.85 Pa, Gas: H2, GasValve: 24.74 V 15:27:30 #38120 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 15:27:33 #38119 /VacuumLog: Chamber: 13.10 mPa, 28.50 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 24.74 V 15:27:36 #38119 /VacuumLog: Chamber: 13.20 mPa, 28.50 C, ForVacuum: 3.35 Pa, Gas: H2, GasValve: 24.74 V 15:27:40 #38119 /VacuumLog: Chamber: 13.30 mPa, 28.50 C, ForVacuum: 3.4 Pa, Gas: H2, GasValve: 24.74 V 15:27:41 #38119 /Trigger: Going through .. 15:27:41 #38119 Discharge/HWTrigger: Going through .. 15:27:41 #38119 Discharge/HWTrigger: Going with trigger Tch3 - TBt 1000 15:27:41 #38119 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 15:27:41 #38119 Discharge/HWTrigger: Going with trigger Tch5 - Tist 3000 15:27:44 #38119 /VacuumLog: Chamber: 13.20 mPa, 28.50 C, ForVacuum: 3.45 Pa, Gas: H2, GasValve: 24.74 V 15:27:46 #38119 /ChargingResistorsAllON: Diving into .. 15:27:47 #38119 /VacuumLog: Chamber: 13.00 mPa, 28.50 C, ForVacuum: 3.45 Pa, Gas: H2, GasValve: 0.00 V 15:27:49 #38119 /SecurePostDischargeState: Going through .. 15:27:49 #38120 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 15:27:51 #38119 /VacuumLog: Chamber: 3.58 mPa, 28.50 C, ForVacuum: 2.5 Pa, Gas: NULL, GasValve: 0.00 V 15:27:54 #38119 /VacuumLog: Chamber: 3.38 mPa, 28.60 C, ForVacuum: 1.9 Pa, Gas: NULL, GasValve: 0.00 V 15:27:58 #38119 /VacuumLog: Chamber: 3.25 mPa, 28.60 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 15:28:02 #38119 /VacuumLog: Chamber: 3.14 mPa, 28.60 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 15:28:03 #38120 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 15:28:05 #38120 Papouch-Za/RawDataAcquiring: Papouch-Za: Start of acquiring 15:28:05 #38119 /VacuumLog: Chamber: 3.06 mPa, 28.60 C, ForVacuum: 1.85 Pa, Gas: NULL, GasValve: 0.00 V 15:28:09 #38119 /VacuumLog: Chamber: 3.06 mPa, 28.60 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 15:28:12 #38119 /VacuumLog: Chamber: 3.01 mPa, 28.50 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 15:28:16 #38119 /VacuumLog: Chamber: 2.95 mPa, 28.50 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 15:28:20 #38119 /VacuumLog: Chamber: 2.90 mPa, 28.60 C, ForVacuum: 1.8 Pa, Gas: NULL, GasValve: 0.00 V 15:28:23 #38119 /VacuumLog: Chamber: 2.86 mPa, 28.50 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 15:28:24 #38120 Papouch-Za/RawDataAcquiring: Papouch-Za: End of acquiring 15:28:25 #38120 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 15:28:27 #38119 /VacuumLog: Chamber: 2.81 mPa, 28.60 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 15:28:29 #38120 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:28:29 #38120 NIstandard/RawDataAcquiring: NIstandard: Start of acquiring 15:28:30 #38120 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:28:30 #38120 NIstandard/RawDataAcquiring: NIstandard: End of acquiring 15:28:31 #38119 /VacuumLog: Chamber: 2.77 mPa, 28.50 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 15:28:34 #38119 /VacuumLog: Chamber: 2.72 mPa, 28.50 C, ForVacuum: 1.75 Pa, Gas: NULL, GasValve: 0.00 V 15:28:38 #38119 /VacuumLog: Chamber: 2.68 mPa, 28.50 C, ForVacuum: 1.7 Pa, Gas: NULL, GasValve: 0.00 V 15:28:42 #38119 /VacuumLog: Chamber: 2.64 mPa, 28.50 C, ForVacuum: 1.7 Pa, Gas: NULL, GasValve: 0.00 V 15:28:45 #38119 /VacuumLog: Chamber: 2.61 mPa, 28.50 C, ForVacuum: 1.7 Pa, Gas: NULL, GasValve: 0.00 V 15:28:49 #38119 /VacuumLog: Chamber: 2.58 mPa, 28.50 C, ForVacuum: 1.7 Pa, Gas: NULL, GasValve: 0.00 V 15:28:53 #38119 /VacuumLog: Chamber: 2.54 mPa, 28.50 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 15:28:56 #38119 /VacuumLog: Chamber: 2.51 mPa, 28.60 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 15:29:00 #38119 /VacuumLog: Chamber: 2.48 mPa, 28.50 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 15:29:03 #38119 /VacuumLog: Chamber: 2.45 mPa, 28.50 C, ForVacuum: 1.65 Pa, Gas: NULL, GasValve: 0.00 V 15:29:07 #38119 /VacuumLog: Chamber: 2.42 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:10 #38119 /VacuumLog: Chamber: 2.39 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:14 #38119 /VacuumLog: Chamber: 2.37 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:18 #38119 /VacuumLog: Chamber: 2.34 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:21 #38119 /VacuumLog: Chamber: 2.32 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:23 #38120 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 15:29:25 #38119 /VacuumLog: Chamber: 2.29 mPa, 28.60 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V 15:29:26 #38120 /DischargeFunction: General Calling FinalDischargeOperations 15:29:29 #38119 /VacuumLog: Chamber: 2.27 mPa, 28.50 C, ForVacuum: 1.6 Pa, Gas: NULL, GasValve: 0.00 V