07:00:24 #38298 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 07:00:25 #38298 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 07:00:26 #38298 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 07:00:27 #38298 /GetReadyTheDischarge: Going with gas pressure 12 07:00:27 #38298 /GetReadyTheDischarge: Going with gas type H 07:00:27 #38298 /GetReadyTheDischarge: Discharge with Hydrogen request 07:00:27 #38298 /GetReadyTheDischarge: Discharge with 12 mPa request 07:00:27 #38298 /VacuumLog: Chamber: 1.56 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 0.00 V ith Bt CW request 07:00:27 #38298 /GetReadyTheDischarge: Going with CD_orientation CW 07:00:28 #38298 /GetReadyTheDischarge: Discharge with CD CW request 07:00:28 #38298 /GetReadyTheDischarge: It is a dummy discharge - without Charger action 07:00:31 #38298 /VacuumLog: Chamber: 1.56 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 22.42 V 07:00:33 #38298 /GetReadyTheDischarge: Ascending from .. 07:00:34 #38298 /VacuumLog: Chamber: 2.00 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: H2, GasValve: 24.51 V 07:00:38 #38298 /VacuumLog: Chamber: 16.20 mPa, 26.90 C, ForVacuum: 2.4 Pa, Gas: H2, GasValve: 25.66 V 07:00:42 #38298 /VacuumLog: Chamber: 18.00 mPa, 26.90 C, ForVacuum: 4.6 Pa, Gas: H2, GasValve: 22.86 V 07:00:44 #38298 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 07:00:45 #38298 /VacuumLog: Chamber: 9.86 mPa, 26.80 C, ForVacuum: 3.85 Pa, Gas: H2, GasValve: 22.69 V 07:00:46 #38298 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 07:00:46 #38298 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 07:00:46 #38298 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 07:00:49 #38298 /VacuumLog: Chamber: 9.59 mPa, 26.90 C, ForVacuum: 3.4 Pa, Gas: H2, GasValve: 22.69 V 07:00:53 #38298 /VacuumLog: Chamber: 9.43 mPa, 27.00 C, ForVacuum: 3.3 Pa, Gas: H2, GasValve: 22.69 V 07:00:56 #38298 /VacuumLog: Chamber: 9.29 mPa, 27.00 C, ForVacuum: 3.3 Pa, Gas: H2, GasValve: 22.69 V 07:01:00 #38298 /VacuumLog: Chamber: 9.17 mPa, 27.00 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 22.69 V 07:01:03 #38298 /ChargingResistorsAllON: Diving into .. 07:01:04 #38298 /VacuumLog: Chamber: 9.06 mPa, 26.90 C, ForVacuum: 3.25 Pa, Gas: H2, GasValve: 0.00 V 07:01:06 #38298 /SecurePostDischargeState: Going through .. 07:01:06 #38298 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 07:01:07 #38298 /VacuumLog: Chamber: 1.61 mPa, 26.90 C, ForVacuum: 2.2 Pa, Gas: NULL, GasValve: 0.00 V 07:01:11 #38298 /VacuumLog: Chamber: 1.55 mPa, 27.00 C, ForVacuum: 1.45 Pa, Gas: NULL, GasValve: 0.00 V 07:01:14 #38298 /VacuumLog: Chamber: 1.54 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:18 #38298 /VacuumLog: Chamber: 1.54 mPa, 26.90 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 07:01:20 #38298 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 07:01:22 #38298 /VacuumLog: Chamber: 1.53 mPa, 26.90 C, ForVacuum: 1.3 Pa, Gas: NULL, GasValve: 0.00 V 07:01:25 #38298 /VacuumLog: Chamber: 1.53 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:29 #38298 /VacuumLog: Chamber: 1.53 mPa, 27.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:33 #38298 /VacuumLog: Chamber: 1.52 mPa, 27.00 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:36 #38298 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 07:01:36 #38298 /VacuumLog: Chamber: 1.52 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:40 #38298 /VacuumLog: Chamber: 1.52 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:44 #38298 /VacuumLog: Chamber: 1.52 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:46 #38298 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 07:01:47 #38298 /VacuumLog: Chamber: 1.52 mPa, 26.90 C, ForVacuum: 1.35 Pa, Gas: NULL, GasValve: 0.00 V 07:01:49 #38298 /DischargeFunction: General Calling FinalDischargeOperations