11:28:59 #38360 Discharge/PrepareDischargeEnv@SHM: Command Line Request: UPP 11:28:59 #38360 /Broadcast: **Dirigent: PREPAREDISCHARGEENV@SHM@EVERYWHERE end 11:29:01 #38360 /LogTheDeviceAction: The Preionization action on stage with GetReadyTheDischarge 11:29:01 #38360 /VacuumLog: Chamber: 5.76 mPa, 56.30 C, ForVacuum: 2.2 Pa, Gas: NULL, GasValve: 0.00 V 11:29:01 #38360 /GetReadyTheDischarge: Going with gas pressure 20 11:29:01 #38360 /GetReadyTheDischarge: Going with gas type H 11:29:01 #38360 /GetReadyTheDischarge: Discharge with Hydrogen request 11:29:01 #38360 /GetReadyTheDischarge: Discharge with 20 mPa reques11:29:01 #38360 /GetReadyTheDischarge: Going with Bt_orientation CW 11:29:01 #38360 /GetReadyTheDischarge: Discharge with Bt CW request 11:29:01 #38360 /GetReadyTheDischarge: Going with CD_orientation CW 11:29:01 #38360 /GetReadyTheDischarge: Discharge with CD CW request 11:29:04 #38360 /VacuumLog: Chamber: 5.72 mPa, 56.20 C, ForVacuum: 2.15 Pa, Gas: H2, GasValve: 23.48 V 11:29:08 #38360 /VacuumLog: Chamber: 9.46 mPa, 56.10 C, ForVacuum: 2.35 Pa, Gas: H2, GasValve: 27.08 V 11:29:08 #38360 /GetReadyTheDischarge: Bt capacitor charging started 11:29:12 #38360 /VacuumLog: Chamber: 30.00 mPa, 56.10 C, ForVacuum: 4.75 Pa, Gas: H2, GasValve: 24.58 V 11:29:13 #38360 /GetReadyTheDischarge: Cd capacitor charging started 11:29:13 #38360 /ChargingResistorsAllOFF: Diving into .. 11:29:13 #38360 /GetReadyTheDischarge: U_Bt: 800, Hrana: 98 11:29:13 #38360 /GetReadyTheDischarge: U_Et: 400, Hrana: 98 11:29:13 #38360 /GetReadyTheDischarge: Charging ... HV=-10 V 11:29:14 #38360 /GetReadyTheDischarge: Charging ... HV=-10 V 11:29:14 #38360 /GetReadyTheDischarge: Charging ... HV=-10 V 11:29:14 #38360 /GetReadyTheDischarge: Charging ... HV=20 V 11:29:15 #38360 /GetReadyTheDischarge: Charging ... HV=18 V 11:29:15 #38360 /VacuumLog: Chamber: 21.10 mPa, 56.00 C, ForVacuum: 5.2 Pa, Gas: H2, GasValve: 24.44 V 11:29:15 #38360 /GetReadyTheDischarge: Charging ... HV=69 V 11:29:16 #38360 /GetReadyTheDischarge: Charging ... HV=69 V 11:29:16 #38360 /GetReadyTheDischarge: Charging ... HV=69 V 11:29:17 #38360 /GetReadyTheDischarge: Charging ... HV=115 V 11:29:17 #38360 /GetReadyTheDischarge: Charging ... HV=115 V 11:29:17 #38360 /GetReadyTheDischarge: Charging ... HV=162 V 11:29:18 #38360 /GetReadyTheDischarge: Charging ... HV=162 V 11:29:18 #38360 /GetReadyTheDischarge: Charging ... HV=18 V 11:29:19 #38360 /GetReadyTheDischarge: Charging ... HV=208 V , Gas: H2, GasValve: 24.35 V 11:29:19 #38360 /GetReadyTheDischarge: Charging ... HV=208 V 11:29:20 #38360 /GetReadyTheDischarge: Charging ... HV=253 V 11:29:20 #38360 /GetReadyTheDischarge: Charging ... HV=253 V 11:29:21 #38360 /GetReadyTheDischarge: Charging ... HV=253 V 11:29:21 #38360 /GetReadyTheDischarge: Charging ... HV=297 V 11:29:21 #38360 /GetReadyTheDischarge: Charging ... HV=297 V 11:29:22 #38360 /GetReadyTheDischarge: Charging ... HV=18 V 11:29:22 #38360 /GetReadyTheDischarge: Charging ... HV=340 V 11:29:23 #38360 /GetReadyTheDischarge: Charging ... HV=340 V , Gas: H2, GasValve: 24.35 V 11:29:23 #38360 /GetReadyTheDischarge: Charging ... HV=379 V 11:29:24 #38360 /GetReadyTheDischarge: Charging ... HV=379 V 11:29:24 #38360 /GetReadyTheDischarge: Charging ... HV=417 V 11:29:24 #38360 /GetReadyTheDischarge: Cd capacitor charging finished @ 417 V 11:29:25 #38360 /GetReadyTheDischarge: Charging ... HV=417 V 11:29:25 #38360 /GetReadyTheDischarge: Charging ... HV=458 V 11:29:25 #38360 /GetReadyTheDischarge: Charging ... HV=458 V 11:29:26 #38360 /GetReadyTheDischarge: Charging ... HV=458 V 11:29:26 #38360 /GetReadyTheDischarge: Charging ... HV=497 V , Gas: H2, GasValve: 24.35 V 11:29:27 #38360 /GetReadyTheDischarge: Charging ... HV=497 V 11:29:27 #38360 /GetReadyTheDischarge: Charging ... HV=537 V 11:29:28 #38360 /GetReadyTheDischarge: Charging ... HV=537 V 11:29:28 #38360 /GetReadyTheDischarge: Charging ... HV=537 V 11:29:28 #38360 /GetReadyTheDischarge: Charging ... HV=576 V 11:29:29 #38360 /GetReadyTheDischarge: Charging ... HV=576 V 11:29:29 #38360 /GetReadyTheDischarge: Charging ... HV=612 V 11:29:30 #38360 /GetReadyTheDischarge: Charging ... HV=612 V 11:29:30 #38360 /GetReadyTheDischarge: Charging ... HV=612 V , Gas: H2, GasValve: 24.35 V 11:29:31 #38360 /GetReadyTheDischarge: Charging ... HV=647 V 11:29:31 #38360 /GetReadyTheDischarge: Charging ... HV=647 V 11:29:31 #38360 /GetReadyTheDischarge: Charging ... HV=18 V 11:29:32 #38360 /GetReadyTheDischarge: Charging ... HV=685 V 11:29:32 #38360 /GetReadyTheDischarge: Charging ... HV=685 V 11:29:33 #38360 /GetReadyTheDischarge: Charging ... HV=719 V 11:29:33 #38360 /GetReadyTheDischarge: Charging ... HV=719 V 11:29:33 #38360 /GetReadyTheDischarge: Charging ... HV=719 V 11:29:34 #38360 /GetReadyTheDischarge: Charging ... HV=751 V 11:29:34 #38360 /GetReadyTheDischarge: Charging ... HV=751 V 11:29:35 #38360 /GetReadyTheDischarge: Charging ... HV=783 V 11:29:35 #38360 /GetReadyTheDischarge: Charging ... HV=783 V 11:29:36 #38360 /GetReadyTheDischarge: Charging ... HV=783 V 11:29:36 #38360 /GetReadyTheDischarge: Charging ... HV=813 V 11:29:36 #38360 /ChargingResistorsAllON: Diving into .. 11:29:37 #38360 /GetReadyTheDischarge: Bt capacitor charging finished @ 813 V 11:29:37 #38360 /VacuumLog: Chamber: 27.60 mPa, 55.60 C, ForVacuum: 5.8 Pa, Gas: H2, GasValve: 24.35 V 11:29:37 #38360 /ChargingResistorsAllON: Diving into .. 11:29:37 #38360 /GetReadyTheDischarge: Ascending from .. 11:29:37 #38360 /Broadcast: **ActualShot: GETREADYTHEDISCHARGE@EVERYWHERE end 11:29:39 #38360 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:29:39 #38360 TektrMSO56-a/LogTheDeviceAction: The BasicDiagnostics action on stage with Arming 11:29:39 #38360 /Broadcast: **ActualShot: ARMING@EVERYWHERE end 11:29:40 #38360 /VacuumLog: Chamber: 27.80 mPa, 55.50 C, ForVacuum: 5.8 Pa, Gas: H2, GasValve: 24.35 V 11:29:44 #38360 /VacuumLog: Chamber: 27.90 mPa, 55.50 C, ForVacuum: 5.85 Pa, Gas: H2, GasValve: 24.35 V 11:29:48 #38360 /VacuumLog: Chamber: 28.10 mPa, 55.40 C, ForVacuum: 5.85 Pa, Gas: H2, GasValve: 24.35 V 11:29:50 #38360 /Trigger: Going through .. 11:29:50 #38360 Discharge/HWTrigger: Going through .. 11:29:50 #38360 Discharge/HWTrigger: Going with trigger Tch3 - TBt 0 11:29:50 #38360 Discharge/HWTrigger: Going with trigger Tch4 - Tcd 1000 11:29:50 #38360 Discharge/HWTrigger: Going with trigger Tch5 - Tist 4000 11:29:51 #38360 /VacuumLog: Chamber: 28.30 mPa, 55.30 C, ForVacuum: 5.9 Pa, Gas: H2, GasValve: 24.35 V 11:29:54 #38360 /ChargingResistorsAllON: Diving into .. 11:29:55 #38360 /VacuumLog: Chamber: 28.50 mPa, 55.30 C, ForVacuum: 5.9 Pa, Gas: H2, GasValve: 0.00 V 11:29:57 #38360 /SecurePostDischargeState: Going through .. 11:29:57 #38360 /Broadcast: **ActualShot: SECUREPOSTDISCHARGESTATE@EVERYWHERE end 11:29:58 #38360 /VacuumLog: Chamber: 5.41 mPa, 55.20 C, ForVacuum: 3.6 Pa, Gas: NULL, GasValve: 0.00 V 11:30:02 #38360 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@DISCHARGEBASICMANAGEMENT end 11:30:02 #38360 /VacuumLog: Chamber: 5.22 mPa, 55.20 C, ForVacuum: 2.2 Pa, Gas: NULL, GasValve: 0.00 V 11:30:06 #38360 /VacuumLog: Chamber: 5.13 mPa, 55.10 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:09 #38360 /VacuumLog: Chamber: 5.06 mPa, 55.10 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:13 #38360 /VacuumLog: Chamber: 5.00 mPa, 55.00 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:17 #38360 /VacuumLog: Chamber: 4.95 mPa, 54.90 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:20 #38360 /VacuumLog: Chamber: 4.91 mPa, 54.90 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:24 #38360 /VacuumLog: Chamber: 4.87 mPa, 54.80 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:28 #38360 /VacuumLog: Chamber: 4.83 mPa, 54.70 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:30 #38360 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@ONSTAGE_WAVE end 11:30:31 #38360 /VacuumLog: Chamber: 4.79 mPa, 54.70 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:35 #38360 /VacuumLog: Chamber: 4.76 mPa, 54.60 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:38 #38360 /VacuumLog: Chamber: 4.72 mPa, 54.60 C, ForVacuum: 2.05 Pa, Gas: NULL, GasValve: 0.00 V 11:30:40 #38360 /Broadcast: **ActualShot: POSTDISCHARGEANALYSIS@OFFSTAGE_WAVE end 11:30:42 #38360 /VacuumLog: Chamber: 4.69 mPa, 54.50 C, ForVacuum: 2.0 Pa, Gas: NULL, GasValve: 0.00 V 11:30:44 #38360 /DischargeFunction: General Calling FinalDischargeOperations